• Title/Summary/Keyword: Double plate

Search Result 358, Processing Time 0.026 seconds

Experimental and numerical investigation on the seismic behavior of the sector lead rubber damper

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Song Wang;Ke Jiang
    • Earthquakes and Structures
    • /
    • v.26 no.3
    • /
    • pp.203-218
    • /
    • 2024
  • Beam-column joints in the frame structure are at high risk of brittle shear failure which would lead to significant residual deformation and even the collapse of the structure during an earthquake. In order to improve the damage issue and enhance the recoverability of the beam-column joints, a sector lead rubber damper (SLRD) has been developed. The SLRD can increase the bearing capacity and energy dissipation capacity, and also demonstrating recoverability of seismic performance following cyclic loading. In this paper, the hysteretic behavior of SLRD was experimentally investigated in terms of the regular hysteretic behavior, large deformation behavior and fatigue behavior. Furthermore, a parametric analysis was performed to study the influence of the primary design parameters on the hysteretic behavior of SLRD. The results show that SLRD resist the exerted loading through the shear capacity of both rubber parts coupled with the lead cores in the pre-yielding stage of lead cores. In the post-yielding phase, it is only the rubber parts of the SLRD that provide the shear capacity while the lead cores primarily dissipate the energy through shear deformation. The SLRD possesses a robust capacity for large deformation and can sustain hysteretic behavior when subjected to a loading rotation angle of 1/7 (equivalent to 200% shear strain of the rubber component). Furthermore, it demonstrates excellent fatigue resistance, with a degradation of critical behavior indices by no more than 15% in comparison to initial values even after 30 cycles. As for the designing practice of SLRD, it is recommended to adopt the double lead core scheme, along with a rubber material having the lowest possible shear modulus while meeting the desired bearing capacity and a thickness ratio of 0.4 to 0.5 for the thin steel plate.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Retrodirective Antenna Array Based on Double Conversion Mixer System and Its Application to Cancellation of Electromagnetic Reflections (이중 변환 믹서 방식 역지향 배열 안테나 시스템의 반사 전자기파 상쇄 응용)

  • Ha, Jungje;Jang, Sunghoon;Lee, Yongshik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1181-1189
    • /
    • 2013
  • In this paper, a retrodirective anatenna array system is proposed and the possibility of actively cancelling electromagnetic waves based on this system is investigated. When a rectrodirective array system receives an electromagnetic wave, it can send waves in the direction of the incoming signal without prior knowledge of the direction. In applications to cancellation of radar signals, the system can generate and send signals to the radar so that it cancels the radar signals that are reflected back to the radar. In such a system, isolation between the input and output ports is a key factor that determines the effectiveness of cancellation. In this work, a dual-conversion mixer system is proposed to maximize the isolation. Since this minimizes the difference between the direction of reflection of radar signals and the transmission of cancellation signals, the effectiveness of cancellation is maximized. Experimental results for a metallic plate and metallic cylinder shows as much as 29-dB reduction in reflection for a $2{\times}2$ retrodirective array based on proposed dual-conversion mixer system, which verifies the proposed method of active cancellation.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Synthesis and Characterization of Low-Dimensional Chalcogenide Compound via a Molten Salt Method (용융염법을 이용한 저차원 구조의 금속 칼코겐 화합물의 합성 및 구조 특성연구)

  • Choi, Duc-Su;Yun, Hye-Sik;Oh, Hwa-Suk;Kim, Don;Yun, Ho-Seop;Park, Youn-Bong
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.5
    • /
    • pp.504-509
    • /
    • 2004
  • The reaction of Cu metal with mixed alkali metal polyselenide flux ($KNaSe_x$) produced large plate-like crystals of $KCu_4Se_3$. The structure of $KCu_4Se_3$, determined with X-ray single crystal diffraction techniques, is tetragonal (P4/mmm, a=4.013(1))${\AA}$, c=9.712(1))${\AA}$, z=1, R=6.7%). The structure is composed $[Cu_4Se_3]_n^{n-}$double layers which are made of fused anti PbO-type Cu2Se2 layers. Temperature variable resistivity measurement on single crystal of $KCu_4Se_3$ shows metallic behavior ranging from $1.8{\times}10^{-4}{\Omega}{\cdot}cm$ (at 300 K) to $1.0{\times}10^{-6}{\Omega}{\cdot}cm$ (at 20 K).

The Results of Surgical Treatment of Comminuted Fractures of Distal humerus (원위 상완골 분쇄 골절의 수술적 치료 결과)

  • Cho Nam-Su;Park Sung-Woo;Jung Ki-Yoen;Rhee Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

Anatomical Study of Chordodes koreensis in the Parasitic Phase Using Electron Microscopy (개의 구토물에서 분리한 오디흑연가시(철선충)의 전자현미경을 이용한 해부학적 소견)

  • Son, Hwa-Young;Chae, Joon-Seok;Kim, Nam-Soo;Kim, Hyeon-Cheol;Cho, Jeong-Gon;Park, Bae-Keun
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.586-590
    • /
    • 2009
  • Horsehair worms (Chordodes koreensis) develop as parasites in the bodies of grasshoppers, crickets, cockroaches, and some beetles. Chordodes koreensis is an accidental parasite of humans, livestock, or pets and poses no public health threat. The male of Chordodes koreensis in the later larval stage from canine vomitus was investigated by the scanning and transmission electron microscopy. In cross sections, the body wall is composed of four components namely epicuticle, cuticle, epidermis, and muscle layers. The parenchymal tissue fills the rest of the body and surrounds the visceral organs such as intestine, and ventral nerve cord but testes were not found. The epicuticle is a thin superficial layer whose surface shows rows of polygonal elevations called areoles. The cuticle has 17 layers of collagenous fibers spirally wound about the long axis of the worm. The section through the cuticle reveals the layers of large fibers cut obliquely lengthwise, alternating with layers of fibers sectioned obliquely crosswise. The layers of large fiber formed a double helix about longitudinal axis of the worm. The epidermis is a single layer. The muscles were interrupted by the nervous lamella in the only midventral portion. The medulla of muscle plate is composed of lightly stained cytoplasm, mitochondria, weakly developed endoplasmic reticulum, and glycogen granules. Between the medulla of a cell and the plasmalemma lies a broad cortical zone of myofilaments. The circular muscles are absent. The characteristic feature of the cytoplasm is that there was no content in peripheral mesenchyme, but was an abundance of large clear vacuoles which give the cytosome a foamy appearance. The nucleus of mesenchyme is not easily identified in our specimens.

Studies on the Improvement of Quality and Shelf-life of Traditional Marinated Beef(Galbi) as Affected by Packaging Method during Storage at$-1^{\circ}C$ (포장방법에 따른 전통 양념갈비의 품질 및 저장성 개선에 관한 연구)

  • Kim, Cheon-Jei;Jeong, Jong-Yon;Lee, Eui-Soo;Song, Hyun-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.792-798
    • /
    • 2002
  • Investigations on the microbiological, physicochemical, and sensory characteristics of seasoned Galbi using various packaging methods during storage at $-1^{\circ}C$ revealed no significant differences in pH values and acidities of seasoned Galbi depending on packaging methods and storage periods. Increments of thiobarbituric acid values of seasoned Galbi with non-evacuated packaging and modified atmosphere packaging were superior to those of vacuum packaging and double-film vacuum packaging during storage. Seasoned Galbi with non-evacuated packaging showed the highest volatile basic nitrogen value, and total plate count significantly increased compared to other packaging methods after 15 days storage. Coliform bacteria showed an average count of 2.35 log CFU/g at the beginning of storage, which increased slightly from 7 to 15 days, and was maintained under 4.0 log CFU/g after 15 days storage. The sensory evaluation revealed that non-evacuated packaging scored relatively lower than other methods in color, flavor, off-odor, and overall acceptability after storage.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.