• Title/Summary/Keyword: Double line

Search Result 777, Processing Time 0.033 seconds

Leak Before Break Evaluation of Surge Line by Considering CPE under Beyond Design Basis Earthquake (설계초과지진시 CPE를 고려한 밀림관 파단전누설 평가)

  • Seung Hyun Kim;Youn Jung Kim;Han-geol Lee;Sun Yeh Kang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2022
  • Nuclear Power Plants (NPP) should be designed to have sufficient safety margins and to ensure seismic safety against earthquake that may occur during the plant life time. After the 9.12 Gyeongju earthquake accident, the structural integrity of nuclear power plants due to the beyond design basis earthquake is one of key safety issues. Accordingly, it is necessary to conduct structural integrity evaluations for domestic NPPs under beyond design basis earthquake. In this study, the Level 3 LBB (Leak Before Break) evaluation was performed by considering the beyond design basis earthquake for the surge line of a OPR1000 plant of which design basis earthquake was set to be 0.2g. The beyond design basis earthquake corresponding to peak ground acceleration 0.4g at the maximum stress point of the surge line was considered. It was confirmed that the moment behaviors of the hot leg and pressurized surge nozzle were lower than the maximum allowable loading in moment-rotation curve. It was also confirmed that the LBB margin could be secured by comparing the LBB margin through the Level 2 method. It was judged that the margin was secured by reducing the load generated through the compliance of the pipe.

A Study on Cutting Pattern Generation of Membrane Structures Using Spline Curves (스플라인 곡선을 이용한 막구조물의 재단도 작성에 관한 연구)

  • Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.1
    • /
    • pp.109-119
    • /
    • 2012
  • For membrane structure, there are three main steps in design and construction, which are form finding, statistical load analysis, and cutting patterning. Unlike the first two stages, the step of cutting pattern involves the translation of a double-curved surface in 3D space into a 2D plane with minimal error. For economic reasons, the seam lines of generated cutting patterns rely greatly on the geodesic line. Generally, as searching regions of the seam line are plane elements in the step of shape analysis, the seam line is not a smooth curve, but an irregularly divided straight line. So, it is how we make an irregularly divided straight line a smooth curve that defines the quality of the pattern. Accordingly, in this paper, we analyzed interpolation schemes using spline, and apply these methods to cutting pattern generation on the curved surface. To generate the pattern, three types of spline functions were used, i.e., cubic spline function, B-spline, and least-square spline approximation, and simple model and the catenary-shaped membrane was adopted to examine the result of generation. The result of comparing the approximation curves by the number of elements and the number of extracted nodes of simple model revealed that the seam line for less number of extracted nodes with large number of elements were more efficient, and the least-square spline approximation provided smoother seam line than other methods.

A Study on Fault Characteristics of Wind Power in Distribution Feeders (풍력발전(DFIG)의 고압배전선로의 사고특성 해석에 관한 연구)

  • Kim, So-Hee;Kim, Byung-Ki;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1288-1295
    • /
    • 2012
  • Korea Ministry of Knowledge Economy has estimated that wind power (WP) will be occupied 37% in 2020 and 42% in 2030 of the new energy sources, and also green energies such as photovoltaic (PV) and WP are expected to be interconnected with the distribution system because of Renewable Portfolio Standard (RPS) starting from 2012. However, when a large scale wind power plant (over 3[MW]) is connected to the traditional distribution system, protective devices (mainly OCR and OCGR of re-closer) will be occurred mal-function problems due to changed fault currents it be caused by Wye-grounded/Delta winding of interconnection transformer and %impedance of WP's turbine. Therefore, when Double-Fed Induction Generator (DFIG) of typical WP's Generator is connected into distribution system, this paper deals with analysis three-phase short, line to line short and a single line ground faults current by using the symmetrical components of fault analysis and PSCAD/EMTDC modeling.

Simulation for characteristics of various type SFCLs (유형별 초전도 한류기의 특성에 대한 시뮬레이션)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon;Han, Byoung-Sung
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.338-342
    • /
    • 1999
  • We simulated the current limiting characteristics of resistive and inductive SFCLs with 100 ${\omega}$ of impedances for a single and double line-to-ground faults in the 154 kV grid between two substations nearby Seoul. The transient current at the faults includes not. only high AC current up to 44 kA but also significant DC component as high as 4 kA. The DC current is greater and lasts longer for the double line-to-ground fault than for the single line-to-ground fault. The inductive SFCL limited the fault current more effectively than the resistive one. The DC component, however, was greater and diminishes slower for the inductive SFCL than for the resistive one.

  • PDF

A Study on Fault Characteristics of DFIG in Distribution Systems Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전의 배전계통 사고특성에 관한 연구)

  • Son, Joon-Ho;Kim, Byung-Ki;Jeon, Jin-Taek;Rho, Dae-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.2
    • /
    • pp.47-56
    • /
    • 2011
  • Korea Ministry of Knowledge Economy has estimated that wind power (WP) will be occupied 37% in 2020 and 42% in 2030 of the new energy sources, and also green energies such as photovoltaic (PV) and WP are expected to be interconnected with the distribution system because of Renewable Portfolio Standard (RPS) starting from 2012. However, when a large scale wind power plant (over 3[MW]) is connected to the traditional distribution system, protective devices (mainly OCR and OCGR of re-closer) will be occurred mal-function problems due to changed fault currents it be caused by Wye-grounded/Delta winding of interconnection transformer and %impedance of WP's turbine. Therefore, when Double-Fed Induction Generator (DFIG) of typical WP's Generator is connected into distribution system, this paper deals with analysis three-phase short, line to line short and a single line ground faults current by using the symmetrical components of fault analysis and PSCAD/EMTDC modeling.

A Study on the Fare Elasticities of DST Applications; An Empirical Analysis (경전선 이단적재열차(DST) 도입을 위한 운임 탄력성 조사 연구)

  • Yun, Donghee;Lee, Jinsun;Kim, Ickhee
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.517-523
    • /
    • 2012
  • Double Stack Train(DST) is being used variously around USA and Canada. The greatest advantage of the DST is mass transportation without extending the length of freight train and number of cars. So the DST system can be a kind of innovative train to increase the competitiveness of rail logistic business. As the domestic rail logistic increase, for enhancement of environment friendly green transportation amount, the DST needs more for efficiency. In this study, as the alternative way to introduce the DST to the Kyungbu Line, it's investigated the extensibility of rail freight with the relation of rail fare discount and examined the necessity of pilot business to the Kyungjeon Line which was expected comparatively lower cost. If the DST system is introduced to the Kyungjeon Line, the cost of mass transportation can be much lower and then the comparativeness of rail transportation will be increased, therefore logistic companies can have some margin additionally. In the result of survey to the related companies, if rail transportation fare is 37.7 % cheaper than current road transportation fare, the modal shift can be transferred by maximum 100%.

A Study on New Broadband Phase Shifter using λ/8 Parallel Stubs (λ/8 병렬 스터브들을 이용한 새로운 광대역 위상 천이기에 대한 연구)

  • 엄순영;정영배;전순익;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.657-666
    • /
    • 2002
  • In this paper, a new broadband phase shifter to adjust the slope of dispersive phase characteristic for frequency of transmission network was proposed. The new fundamental network consists of a fixed main line with a length of λ/2 at the center frequency and two double stubs, each with a length of λ/8 at the center frequency, which are open and shorted, respectively, and which are shunted at the edge points of the main line. Characteristic impedances of the main line and two parallel double stubs are adjusted to produce a minimum phase error and to obtain an input and output match at the desired phase shift. Especially, the proposed structure is especially suitable for a broadband phase shifter with large phase shifts more than 90$^{\circ}$, and it is operated in the octave bandwidth. To verify the usefulness of a new broadband phase shifter, each 45$^{\circ}$-, 90$^{\circ}$-, 180$^{\circ}$-bit phase shifter and 3-bit phase shifter(45$^{\circ}$-phase step), which is cascaded in series, operated at the center frequency 3 GHz were designed, fabricated and experimented. The measured results were in very close agreement with the corresponding simulation results over the bandwidth of I/O impedance match and phase error for each phase shift.

CONTINUOUS POSTOPDRATIVE BLEEDING AFTER PRIMARY PALATORRHAPHY;A CASE REPORT (일차 구개성형술 후 발생된 지속적인 술후출혈;증례보고)

  • Shim, Cheong-Hwan;Kim, Young-Kyun;Chae, Byung-Kuk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.458-460
    • /
    • 2001
  • A 11-month-old infancy was referred for treatment of cleft palate. The patient's congenital deformities had included oronasal fistula on the soft palate and bifid uvula. Furrow double-opposing Z-plasty was performed under general anesthesia. However, postoperative bleeding developed at ward. Despite the pressure of operative wound, venous oozing continued and hemoglobin concentration and RBC were decreased (Hb: 5.5g/dL, RBC: $1.98{\times}10^6/mm^3$). The patient was pale and confused and transferred to Surgical Intensive Care Unit(SICU) We could not keep the peripheral venous line and there was a high risk of hypovolemic shock. Emergency transfusion was performed through the central femoral venous line and emergency operation for bleeding control was carried out. We explored the operation site and found bleeding point from the posterior pharyngeal wall. Electrocoagulation and surgicel packing were carried out and bleeding was stopped.

  • PDF

BIACORE 바이오센서를 이용한 B형 간염 표면항원 정량분석의 기초연구

  • Yu, Chang-Hun;Ryu, Gang;Jeon, Jun-Yeong;Lee, Hyeon-Ik;Choe, Seong-Cheol;Lee, Eun-Gyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.231-234
    • /
    • 2001
  • We performed a basic experiment for rapid. on-line, real-time measurement of HBsAg by using a BIACORE biosensor, a chip-based sensor utilizing surface plasmon resonance technology to quantify the recognition and interaction of biomolecules. We immobilized an a -HBsAg antibody on a CM5 chip surface which was activated by N-hydroxysuccinimide for amine coupling with HBsAg, and measured the mass increase from the coupling. This study showed the potential of this biosensor-based method as a rapid, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification.

  • PDF

The Characteristic Improvement of Inverter Output for Static UPS (UPS용 인버터 출력특성 개선)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2051-2053
    • /
    • 1998
  • In spite of nonlinear or step-changing load and line disturbances, the inverter for the UPS must provide the pure sinusoidal output voltage with low THD(Total Harmonics Distortion). This paper proposes an inverter controller for the UPS which has a good dynamic response characteristic and robustness for applying industrial world directly. The inverter output voltage is controlled instantaneously with a double regulation loop by a TMS320C31 Digital Signal Processor so that it has very good dynamic response for nonlinear or step-changing load and line disturbances. To improve the voltage utilization and response characteristics, the Space Vector Modulation(SVM) technique is adapted for the switching method of this system. The characteristics of the proposed control system were verified by simulations and experiments.

  • PDF