• 제목/요약/키워드: Double line

검색결과 776건 처리시간 0.023초

Evaluating New Track Construction Costs of Two Different Options: Conventional Trains vs. Tilting Trains

  • Rho, Hag Lae;Han, Seong Ho;Kim, Gang Seog
    • International Journal of Railway
    • /
    • 제5권3호
    • /
    • pp.103-113
    • /
    • 2012
  • Infrastructure costs could be greatly reduced if the need for bridges and tunnels was reduced, or if the line could be shortened. Tilting trains might be a less costly alternative to building new tracks with large curve radii, because tilting trains can negotiate tighter curves without having to decrease their speeds. Tracks built for tilting trains would be cheaper, as they require fewer bridges and tunnels. This paper compares the construction costs of two different options for the new Dodam-Yeoncheong section on the Central line, which includes 148.65 km of new electrified double-track with a design speed of 250 km/h. The first option is to straighten the high-speed line. The second option is to build a line with small radii curves and run tilting trains on the line. In the first option, tunnels would account for about 51% of the new section. In comparison, the second option would have shorter curves and fewer tunnels and bridges which would reduce construction costs. Furthermore, alignment modifications could be made to several segments on the straight line, making the most of the existing roadbed. The analysis concluded that the line suited to tilting trains would be 95.7 million USD cheaper to build the straight route. That is a savings of 2.8% of the total project cost. However, this option would increase the total travel time of the route by 1.2 minutes, which means it is not necessarily the best choice.

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

3-D fracture analysis of cracked aluminum plates repaired with single and double composite patches using XFEM

  • Jamal-Omidi, Majid;Falah, Mehdi;Taherifar, Davood
    • Structural Engineering and Mechanics
    • /
    • 제50권4호
    • /
    • pp.525-539
    • /
    • 2014
  • Bonded composite-patch repair has been widely used to restore or extend the service life of damaged structures due to its effectiveness as a mechanical repair technique. In this paper using extended finite element method (XFEM), three-dimensional crack models are developed to examine the fracture behavior of centrally cracked aluminum plates repaired with single and double sided composite patches. Stress intensity factor (SIF) at the crack tip is used as the fracture criterion. In this regard, the effects of the crack lengths, patch materials, orientation of plies, adhesive and patch thickness are examined to estimate the SIF of the repaired plate and the repair performance. The obtained results show that composite patches have significant effect on reduction of the SIF at the crack tip. It is also proved that using double symmetric repair, in comparison to single one, reduces considerably SIF at the crack tip. Hence, the residual strength can be improved significantly as well as fatigue life of the structure. Investigation of ply orientation effects shows SIF increase as the ply orientation is changed from $0^{\circ}$ (perpendicular to the advancing crack) to $90^{\circ}$ (parallel to the crack line). However, the effectiveness of the ply orientation depends on the loading direction and the crack direction.

이중 샌드위치 Rib-형 도파로에 기초한 초소형 편광 무의존성 방향성 결합기 (Ultracompact Polarization-Insensitive Directional Coupler based on Double Sandwiched Rib-Type Waveguide)

  • 호광춘
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.171-176
    • /
    • 2014
  • 종방향 모드 전송선로 이론을 이용하여 이중 샌드위치 Rib-형 도파로에 기초한 초소형 편광 무의존성 방향성 결합기 (PIDC)의 편광특성을 자세하게 탐구하였다. 제안한 초소형 방향성 결합기의 편광 무의존성 조건을 얻기 위하여 샌드위치 rib형 도파로의 굴절률과 두께에 때라 변하는 quasi-TE 모드와 quasi-TM 모드의 결합길이와 결합효율을 분석하였다. 수치해석 결과, 수백 마이크로미터 크기의 초소형 편광 무의존성 방향성 결합기는 이중 샌드위치 층의 구조적, 물질적 변수들을 잘 선택함으로써 구현할 수 있음을 보였다. 또한, 이중 샌드위치 rib형 도파로에 분포하는 기본 모드의 프로필이 방향성 결합기의 성능에 어떤 영향을 미치는지에 대하여 조사하였다.

경춘선 성북역 시종착에 따른 수요변화 연구 (A study on the Demand Variations of Gyeongchun line Upon Terminating at Seongbuk Station)

  • 김익희;이상명;윤경만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1707-1714
    • /
    • 2011
  • 상봉~춘천 구간을 운행하는 경춘선 복선전철이 2010년 12월에 운행을 개시함에 따라 시간과 비용측면 모두에서 타 교통수단과 비교하여 우월한 서비스 제공이 가능해졌다. 하지만 수도권 북부(서울시 강북, 도봉, 성북 및 경기 동두천, 양주, 의정부 등)지역에서 경춘선을 이용하기 위해서는 회기와 상봉에서 2회 환승해야 하는 불편이 있다. 이에 본 연구에서는 기존 망우선을 이용하여 경춘선 전동열차의 일부를 성북역에서 시종착함으로써 이용자의 환승 불편을 최소화하고 이에 따른 이용수요 변화를 분석하여 보다 효율적인 열차운행계획을 수립하고자 한다. 본 연구에서는 수요변화분석을 위해 총통행시간(환승시간 및 통행시간)을 고려하여 직접수요모형을 추정하였으며 구간운임 변화에 대한 부분은 고려하지 않아 향후 추가적 보완이 요구된다.

  • PDF

Numerical Modeling for Systematization of Line Heating Process

  • Shin, Jong-Gye;Kim, Won-Don;Lee, Jang-Hyun
    • Journal of Hydrospace Technology
    • /
    • 제2권1호
    • /
    • pp.41-54
    • /
    • 1996
  • Sculptured surface structures such as ship hulls are traditionally formed up to the required double curved shape by line heating method. The nature of the line heating process is a transient thermal process, followed by a thermo-elastic-plastic stress field. The permanant shape is dependent on many factors involved in the process, Among them are torch speed and path, supplied heat type and amount , and plate size. Thus, the work is essentially leaded by experts with lots of experiences. However, in order to effectively improve productivity through automation, each factor should be clearly examined how much it affects the final shape. This can not be done only by experiments, but can be achieved by a mechanics-based approach. In this paper, we propose a conceptual configuration for plate forming system, and then present simulations of the line heating process with numerical data in practices and suggest a computerized process of the line heating for practical applications. The modeling of heating torch, water cooling, and the plate to be formed is proposed for the finite element analysis after the mechanics of line heating is studied. Parametric studies are given and discussed for the effects of plate thickness, torch speed and initial curvature in forming a saddle typed surface.

  • PDF

Grounding Line Change of Ronne Ice Shelf, West Antarctica, from 1996 to 2015 Observed by using DDInSAR

  • Han, Soojeong;Han, Hyangsun;Lee, Hoonyol
    • 대한원격탐사학회지
    • /
    • 제34권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Grounding line of a glacier or ice shelf where ice bottom meets the ocean is sensitive to changes in the polar environment. Recent rapid changes of grounding lines have been observed especially in southwestern Antarctica due to global warming. In this study, ERS-1/2 and Sentinel-1A Synthetic Aperture Radar (SAR) image were interferometrically acquired in 1996 and 2015, respectively, to monitor the movement of the grounding line in the western part of Ronne Ice Shelf near the Antarctic peninsula. Double-Differential Interferometric SAR (DDInSAR) technique was applied to remove gravitational flow signal to detect grounding line from the interferometric phase due to the vertical displacement of the tide. The result showed that ERS-1/2 grounding lines are almost consistent with those from Rignot et al. (2011) which used the similar dataset, confirming the credibility of the data processing. The comparison of ERS-1/2 and Sentinle-1A DDInSAR images showed a grounding line retreat of $1.0{\pm}0.1km$ from 1996 to 2015. It is also proved that the grounding lines based on the 2004 MODIS Mosaic of Antarctica (MOA) images and digital elevation model searching for ice plain near coastal area (Scambos et al., 2017), is not accurate enough especially where there is a ice plain with no tidal motion.

Investigating the accretion disk properties of young radio galaxies using the narrow-emission line diagnostics

  • 손동훈;우종학;;;;;김상철
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.49.2-49.2
    • /
    • 2011
  • To investigate whether radio galaxies have systematically different accretion disk compared to radio-quiet AGN, we obtained high quality optical spectra for a sample of 22 young radio galaxies, using the KAST Double Spectrograph at the Lick 3-m telescope. Young radio galaxies are particularly useful since the age of the radio phenomena is comparable to that of accretion disk. Based on the optical emission-line diagnostics of narrow line region, which is thought to be photoionized by the nuclear radiation, we constrain the states of the accretion disk. In addition to strong emission lines, i.e., [O I], [O II], [O III], and [Ne III], we use the [Ar III] line to break the degeneracy between the ionization parameter and the SED shape. We find that young radio galaxies show systematically different emission line ratios compared to radio-quiet Type II AGN, suggesting that young radio galaxies probably have the power-law SED without a strong big blue bump. We will present the main results of the emission-line diagnostics.

  • PDF

고속철도시스템에서 낙뢰로 인해 전차선에 유도되는 서지전압의 해석 (Analysis on Induced Surge Voltage of Electric Car Line affected by Lightning in Rapid-Transit Railway System)

  • 이성근;이건아;고광철
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.65-70
    • /
    • 2015
  • Lightning is one of hazards affecting the rapid-transit railway system. There are two effects, which are direct lightning surge to electric car line and induced lightning surge. Protection methods for the direct lightning surge are studied with various occasions, however, study of induced lightning surge is insufficient in spite of a large or small effects. In this paper, it is analysed the way that serge voltage is induced to electric car line by lightning strikes. By modeling the propagation process and the coupling phenomenon of electromagnetic wave produced by lightning strikes, it is achieved to make integrative circuit model combined with existing electric car model. The study is conducted into three different waveform of electromagnetic wave produced by lightning; rectangular wave, double exponential distribution wave, triangle wave. It is also simulated that the inducing serge is coupled to electric car line in an arbitrary location. The simulation results in that, when rapidly changing rectangular wave is supplied, maximum power is induced to electric car line.