• Title/Summary/Keyword: Double line

검색결과 774건 처리시간 0.044초

산악터널에 인접한 개인 박물관의 발파공해 영향평가 및 굴착 시공사례 (The Blasting Pollution Effects Estimation & The Excavation Construction Case Study Of Personal Museum On Tunnel)

  • 권순섭;이명철;박태순;정인철;이현구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.127-132
    • /
    • 2004
  • The third double-track construction part of work, called Chung Ang Railroad line(Deok-So$\∼$Won-Ju) is in progress and the personal museum located 330m from the starting point of Pal-Dang Tunnel(length=4,470m) line in the canyon is to be effected by rock blasting during the tunnel excavation work, especially museum articles and building itself. This paper is the example of application suitable tunnel rock blasting pattern for excavation after the case study about the investigation and analysis of rock blasting noise pollution during tunnel excavation work. The museum is a three-story building, RC concrete structure and is located 17m from the top of the tunnel, in the center of the double-track line. Comparing estimate vibration frequency with site vibration one, it can be verified the reasonable rock blasting noise pollution as improving the application of tunnel excavation rock blasting pattern. The above pattern has been selected economically and effectively and applied to our construction field.

  • PDF

고속 전력선 통신 시스템을 위한 반복 부호화 기법 (Iterative Coding for High Speed Power Line Communication Systems)

  • 김요철;조봉열;이재조;김진영
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.185-192
    • /
    • 2011
  • 본 논문에서, 고속 PLC 시스템을 위한 반복 부호화 기법인 이중 이진 터보 코드의 성능을 분석하고 실험하였다. PLC 시스템은 고속 데이터 전송에 열악한 환경을 가지므로, 이를 보상하기 위한 강력한 에러 정정 기법은 반드시 필요하다. PLC 채널 모델로서 M. Zimmerman가 안한 모델을 사용하였으며, 노이즈 모델로 Middleton Class A 모델을 적용하였다. 시스템 성능은 비트오류율 (BER) 측면에서 평가하였다. 모의실험 결과로부터 이중 이진 터보 코딩이 PLC 시스템에 상당한 코딩 이득을 제공한다는 것을 확인하였다. 또한 복호화 프로세스에서 사용된 반복 횟수가 증가할수록 BER 성능이 현저하게 향상된다는 것을 알 수 있었으며, 부호율이 증가할수록 시스템 성능이 감소하고, 부호율이 감소할수록 시스템 성능이 증가한다는 것도 확인하였다.

CPW 급전 이중 다이폴 준-야기 안테나 설계 (Design of a CPW-fed Double-Dipole Quasi-Yagi Antenna)

  • 여준호;이종익
    • 한국정보통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.1518-1523
    • /
    • 2018
  • 본 논문에서는 동일면 도파관(coplanar waveguide: CPW)으로 급전되는 이중 다이폴 준-야기 안테나(double-dipole quasi-Yagi antenna; DDQYA)에 대한 설계 방법을 제안하였다. 제안된 CPW-급전 DDQYA는 직렬로 연결된 두 개의 스트립 다이폴 안테나, 접지 반사기, 스트립-쌍 도파기로 구성된다. 신호선이 안테나의 반대쪽 기판에 위치하는 기존의 마이크로스트립 급전선로 대신에 CPW를 사용하여 안테나와 동일면에 급전선로가 위치하여 제작이 용이하다. 스트립-쌍 도파기는 두 개의 수평으로 분리된 스트립들로 구성되며, 고주파수 영역에서 이득을 높이기 위해 두 번째 다이폴 위에 추가하였다. 제안된 CPW-급전 DDQYA 안테나를 FR4 기판에 제작한 결과, 1.66-3.38 GHz(68.3%) 대역에서 전압 정재파비가 2 이하로 측정되었고, 이득은 1.60-2.90 GHz 대역에서 5.0-7.3 dBi로 5 dBi 이상을 유지하는 것을 확인하였다.

Efficacy and safety of low dose oral ketamine for controlling pain and distress during intravenous cannulation in children: a double-blind, randomized, placebo-controlled trial

  • Bagheri, Mahdi;Soltani, Alireza Ebrahim;Qorbani, Mostafa;Sureda, Antoni;Faghihi, Toktam
    • The Korean Journal of Pain
    • /
    • 제35권3호
    • /
    • pp.311-318
    • /
    • 2022
  • Background: Ketamine is widely used in infants and young children for procedural sedation and anesthesia. The aim of this study was to evaluate the efficacy and safety of low dose oral ketamine to control pain and distress in children during intravenous (IV) cannulation. Methods: This is a prospective, randomized, double-blind study, including children aged between 3 and 6 years requiring a non-emergent IV-line placement. Children were randomly assigned to two groups, treated either with oral ketamine or a placebo. All patients were monitored for vital signs. Pain was assessed using the Children's Hospital of Eastern Ontario Pain Scale (CHEOPS) and Wong-Baker Faces Pain Rating Scale (WBFS) scales and sedation using a 5-point sedation score. The facility of IV-line placement was measured by a 3-point scale. Adverse effects were recorded after 1 and 24 hours. Results: A total of 79 and 81 children were entered in the ketamine and placebo groups, respectively. The heart and respiratory rates increased significantly in the placebo group. The median CHEOPS 4 (95% confidence interval [CI]: 3, 4, P < 0.001) and WBFS 6 (95% CI: 4, 6, P < 0.001) scores decreased statistically in the ketamine group. IV-line placement was 50% easier in the ketamine group (95% CI: 37%, 63%, P < 0.001). No serious adverse effects were observed in all cases. Conclusions: Low dose oral ketamine effectively decreased the pain and distress during IV cannulation in children without any significant adverse reactions.

미앤더 라인을 이용한 RFID 태그용 원형 루프 안테나의 소형화 (Miniaturization of Circular Loop Antenna Using Meander Line for RFID Tag Applications)

  • 류홍균;우종명
    • 한국전자파학회논문지
    • /
    • 제18권6호
    • /
    • pp.591-601
    • /
    • 2007
  • 본 논문에서는 UHF 대역($908.5{\sim}914$ MHz)에 사용되는 RFID 태그용 소형 안테나를 원형 루프 안테나로 설계 및 제작하였다. 원형 루프 구조를 미앤더 라인 구조로 변형시킴으로써 원형 루프 안테나의 소형화를 가능하게 하였다. 2단 미앤더 라인 구조를 이용한 소형 원형 루프 안테나의 경우, 안테나 직경이 40 mm로 일반 원형 루프 안테나에 비해 83%의 크기 축소율을 얻었으며, $S_{11}$, -11.9 dB, -10 dB 대역폭 12 MHz(1.3%), 최대 이득 -1.18 dBd의 특성을 얻었다. 또한 알루미늄으로 코팅된 과자 봉지와 같은 평면형 도체에 부착 가능하도록 태그 안테나를 2단 미앤더 라인 구조를 이용하여 반파장 원형 루프 안테나에 적용시킨 반파장 소형 원형 루프 안테나를 고안, 제작하였다. 이 안테나는 접지면을 제외하고 92.1%의 크기 축소율을 얻었으며, $S_{11}$ -16.5 dB, -10 dB 대역폭 48MHz(5%), 최대 이득 -0.58 dBd의 특성을 얻었다. 방사 패턴은 z-y면에서 무지향성 패턴 특성을 나타내었다. 이로써 본 논문에서 제안된 미앤더 라인 구조의 원형 루프 안테나가 RFID 태그 안테나의 소형화에 적합함을 확인하였다.

능동소음제어를 위한 망각형 지연 LMS 알고리듬을 이용한 이중루프제어 모델 (A Double Loop Control Model Using Leaky Delay LMS Algorithm for Active Noise Control)

  • 권기룡;박남천;이건일
    • 한국음향학회지
    • /
    • 제14권3호
    • /
    • pp.28-36
    • /
    • 1995
  • 본 논문에서는 능동소음제어를 위하여 망각형 지연 LMS(least mean square) 알고리듬을 이용한 이중루프제어 모델을 제안하였다. 제안한 이중루푸제어 모델은 계산양을 줄이기 위해 이득과 음향시간지연인자를 이용하여 온라인으로 라우드스피커 특성 및 오차음경로를 추정한다. 이중루프구조를 통한 오차신호의 제어는 보다 견실한 제어시스템이 된다. 음향시간지연을 추정하기 위한 필터의 입력신호는 입력 마이크로폰 신호와 적응필터의 차를 사용한다. 망각형 지연 LMS 알고리듬은 비정상상태에서 계수들의 발산을 방지하기 위해 사용한다. 실제 소음신호에 대하여 제안한 이중루프제어 모델은 소음레벨이 평균 12.9dB정도 감쇠되었다.

  • PDF

Forehead reconstruction using modified double-opposing rotation-advancement flaps for severe skin necrosis after filler injection

  • Kim, Jinwoo;Hwang, Woosuk
    • 대한두개안면성형외과학회지
    • /
    • 제19권1호
    • /
    • pp.64-67
    • /
    • 2018
  • Varying degrees of complications can occur after hyaluronic acid filler injections. Tissue necrosis due to interruption of the vascular supply is an early complication that can be severe. If the site of tissue necrosis due to the filler injection is the forehead, successfully reconstructing the region without distorting the key landmarks is challenging. We describe the case of a 50-year-old man who experienced widespread forehead skin necrosis after hyaluronic acid filler injection in the glabellar area. We successfully covered the forehead area with a $3{\times}4-cm^2$ midline necrotic tissue using the modified double-opposing rotation-advancement flap method. Although modified double-opposing rotation-advancement flap closure has the disadvantage of leaving a longer scar compared to conventional double-opposing rotation-advancement flap closure, the additional incision line made along the superior border of the eyebrow aids in camouflaging the scar and decreases eyebrow distortion. Therefore, it is believed that the modified double-opposing rotation-advancement flap technique is an excellent tool for providing adequate soft tissue coverage and minimal free margin distortion when reconstructing widespread skin necrosis in the central mid-lower forehead that can occur after filler injection in the glabellar area.

실시간 전력계통 시뮬레이터를 이용한 보호계전모델 개발 (Implementation and Verification of Distance Relay Models for Real Time Digital Simulator)

  • 이주훈;윤용범;차승태;이진;최종웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.393-400
    • /
    • 2003
  • This paper discusses how to implement and verify a software model of the digital relay that can be added to real time digital simulator(RTDS) model library and is then subjected to the same outputs as the actual relay. The software model is stand-alone and can be used with real relays. It is also possible to conduct interactive real-time tests when the system effects of the relay action need to be investigated. The characteristics of mho type and the quadrilateral type, which is commonly used in recently developed relays, are modeled in this paper. Single circuit line and double circuit line system are used for model verification. The transmission lines are each 100 km in length and are modeled as distributed parameter lines but not frequency dependent. The transmission lines in the single circuit system are modeled as ideally transposed line. The mutual coupling data with the parallel line was taken account in the transmission lines for the double circuit system. The main CTs and PTs are included and operated in their linear region during the tests. For the purpose of testing the relay model accuracy the faults have been applied at various points on the protected line. Its accuracy is assessed against theoretical values.

봉독의 항독소(IgY)생산을 위한 실험적 연구 (An Experimental Study on Production of Egg Yolk Antibody(IgY) against Bee Venom)

  • 황태준;이승배;권기록
    • 대한약침학회지
    • /
    • 제4권2호
    • /
    • pp.5-15
    • /
    • 2001
  • This study was carried out for production of neutral antibody to bee venom $(anti-phospholipase\;A_2IgY)$. Hen layings were injected repeatedly with bee venom and phospholipase $A_2$ with Freund's adjuvant. Specific antibody in egg yolk from immunized hen laying was separated, and purified, also immunological characteristics of anti phospholipase $A_2\;IgY$ was invested. The results were summarized as follows: 1. Phospholipase $A_2$ was showed single band at molecular weight 17,000 in SDS-PAGE and bee venom was showed two band at molecular weight 17,000 and under molecular weight 6,500 in SDS-PAGE. 2. During 70 days after hen immunized with bee venom and phospholipase $A_2$, antibodies(anti-bee venom IgY) to bee venom were showed poor ELISA value in egg yolk, but antibodies$(anti-Phospholipase\;A_2IgY)$ to phospholipase $A_2$ in egg yolk were increased ELISA value from 8 days or 15 days and found maximum ELISA value at 42 days. Also after booster at 49 days, ELISA value of anti Phospholipase $A_2\;IgY$ in egg yolk was supported at optical density(O.D) 1.0 level, continuously. 3. Titer of phospholipase $A_2\;IgY$ was showed 1: 32,000. 4. In double immunodiffusion test to phospholipase $A_2$ after double dilution of anti-phospholipase $A_2\;IgY$, only precipitation line was made in 1:1 dilution well of anti-Phospholipase $A_2\;IgY$. But In immunodiffusion test to anti-phospholipase $A_2\;IgY$ after double dilution of phospholipase $A_2$, Precipitation line to 250ul/ml well of phospholipase $A_2$ was showed. In double immunodiffusion test to bee venom(1mg/ml) after double dilution anti-phospholipase $A_2\;IgY$, all well without 1:32 dilution well were showed strong precipitation line. 5. In dot bloting test to anti-phospholipase $A_2\;IgY$ after diluting bee venom(0.5mg/ml), dot bloting color was showed clearly to $1/100(5{\mu}g/ml)$ in bee venom.

전기철도 복선화 및 차폐 케이블 적용에 따른 통신선 유도장해 차폐 효과 (Screening Effects of Double-track Electric Railway and Shielded Cables on Communication-Line Inductive Interference)

  • 설일환;최규형
    • 한국산학기술학회논문지
    • /
    • 제14권10호
    • /
    • pp.5148-5155
    • /
    • 2013
  • 전기철도와 인접하여 병행 설치되어 있는 전기통신선에는 전자유도현상에 의한 유도전압이 발생하여 통신장애 및 안전사고가 발생할 수 있다. 이와 같은 유도장해를 경감시키고 통신신뢰성을 확보하기 위하여, 차폐케이블의 적용과 함께 최근 추진되고 있는 복선전철화에 따른 영향을 검토할 필요가 있다. 본 논문에서는 AT급전방식 전기철도에서 인근 통신선에 유기되는 유도전압에 영향을 미치는 각종 인수 및 산출식을 검토하고, 유도전압 발생 예측치를 시뮬레이션을 통하여 정량적으로 분석하였다. 시뮬레이션 결과, 복선철도에서는 단선철도에 비해 통신선 유도잡음 전압이 18[%] 정도 감소하여 타궤조 효과가 영향을 미치는 것으로 나타났다. 또한, 복선철도를 기준으로, 50% 차폐 통신케이블에서는 유도잡음전압이 1/8로 감소하였으며, 15% 차폐통신케이블에서는 1/15로 감소함에 따라 차폐효과가 크고 유도잡음전압 영향을 최소화할 수 있는 것으로 나타났다.