• Title/Summary/Keyword: Double crown

Search Result 77, Processing Time 0.022 seconds

Shear Bond Strength of Zirconia and Ceramics according to Dental Zirconia Surface Treatment (치과용 지르코니아 표면처리방법에 따른 지르코니아와 전장용 도재의 결합강도 관찰)

  • Lee, Gwang-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • Purpose: The dental CAD / CAM system has been popular with the development of the digital dental industry. Zirconia is a typical material in dental CAD / CAM systems. Zirconia crowns are classified into single layer and double layer. This study is about the double layer crown of zirconia. The surface roughness, bond strength and fracture patterns of the zirconia surface were observed. Methods: Zirconia blocks were cut using a low speed cutter. Sintered to form a plate shape (6mm × 6mm × 3mm). The prepared specimens were surface treated in four ways. Surface roughness and bond strength were measured. And the fracture pattern was observed. Results: Result of surface treatment of zirconia. The surface roughness test results were as ET 2.87 ㎛, ST 2.67 ㎛, LT 2.44 ㎛, AT 2.41 ㎛, CN 2.08 ㎛ order. Bond Strength results were as LT 25.09 MPa, AT 23.27 MPa, ST 21.27 MPa, ET 21.09 MPa, CN 16.12 MPa order. Fracture patterns showed cohesive failure of 25-50% of the bond area. Conclusion: Surface roughness, bond strength and fracture pattern of the zirconia surface were observed. Etching the surface treatment of zirconia materials has been shown to affect the surface roughness. Zirconia special binder treatment has been shown to affect the bond strength improvement.

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

The Ground Reinforcement on Daylight Collapsed Block in Driving Work at the National Road No. 3 Line (국도 3호선 터널건설 공사 중 붕락구간에 대한 지반보강)

  • 천병식;정덕교;이태우;정진교
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.02a
    • /
    • pp.14-22
    • /
    • 1999
  • Daylight collapse have been occurred by about 6.$^{0}$ m deep at ground surface which connected to the ground surface and excessive overbreak have been occurred by the space and height of 3.$^1$~6.$^2$m at crown head part of the tunnel during tunnelling of lower-half part after completing upper-half part on tunnelling of a phyllite mountain by NATM method at the construction work of two way-double track national road. This study is a successful illustration case of earth improvement by confirming structural safety of the tunnel in a whole through solving the cause of the tunnel collapse and the work have completed successfully through applying such earth strengthening method as cement mortarㆍcement milk injection, S.G.R, steel pipe reinforced multi-step grouting etc.

  • PDF

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

COMPARISON OF RETENTIVE FORCES OF TEMPORARY CEMENTS AND ABUTMENT HEIGHT USED WITH IMPLANT-SUPPORTED PROSTHESES

  • Lee, Dong-Hee;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.280-289
    • /
    • 2008
  • STATEMENT OF THE PROBLEM: Recent data regarding the effects the cement type and abutment heights on the retentive force of a prosthetic crown are inconsistent and unable to suggest clinical guidelines. PURPOSE OF THE STUDY: This study evaluated the effects of different types of temporary cements and abutment heights on the retentive strength of cement-retained implant-supported prostheses. MATERIALS AND METHODS: Prefabricated implant abutments, 4 mm in diameter, $8^{\circ}$taper per side, and light chamfer margins, were used. The abutment heights of the implants were 4 mm, 5.5 mm and 7 mm. Seven specimens of a single crown similar to a first premolar were fabricated. Six commercially available temporary cements, TempBond, TempBond NE, Cavitec, Procem, Dycal, and IRM, were used in this study. Twenty-four hours after cementation, the retentive strengths were measured using a universal testing machine with a crosshead speed of 0.5 mm/min. The cementation procedures were repeated 3 times. The data was analyzed using two-way analysis of variance and a Tukey test (${\alpha}$=0.05). RESULTS: The tensile bond strength ranged from 1.76 kg to 19.98 kg. The lowest tensile strengths were similar in the TempBond and Cavitec agents. Dycal showed the highest tensile bond strength (P<0.01). More force was required to remove the crowns cemented to the long abutments (P<0.05). CONCLUSION: TempBond and Cavitec agents showed the lowest mean tensile bond strength. The Dycal agent showed more than double the tensile bond strength of the TempBond agent.

Analysis on the Field Measurements with the Construction of Cut and Cover Tunnel (복개 터널구조물의 현장 시공에 따른 계측 분석 사례)

  • 이석원;박시현;최순욱;배규진
    • Tunnel and Underground Space
    • /
    • v.13 no.2
    • /
    • pp.125-137
    • /
    • 2003
  • Field measurements were carried out in this study to investigate the behavior of cut and cover tunnel such as the distribution and the magnitude of the earth pressure during back fill process. Three kinds of measuring instruments, such as the earth pressure load cell, the concrete strain gauge and the reinforcing bar meter of embedded type in concrete structure were installed and measured. Earth pressure load cells measured the outside forces acting on the tunnel lining with radial directions. Three load cells were installed at the crown, the right and the left shoulder of the tunnel, respectively. Three sets of reinforcing bar meter were installed in the double reinforcements of the tunnel lining and their locations were the same with the position of the earth pressure load cells. Concrete strain gauge was installed only one site of the upper compressive part at the tunnel crown. Based on the measurements, the deformation and the earth pressure acting on the tunnel lining were investigated with the back fill process. Considerations on the validity of the field measurements were paid.

Development and growth of the temporal fascia: a histological study using human fetuses

  • Kei Kitamura;Satoshi Ishizuka;Ji Hyun Kim;Hitoshi Yamamoto;Gen Murakami;Jose Francisco Rodriguez-Vazquez;Shin-ichi Abe
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.288-293
    • /
    • 2024
  • The temporal fascia is a double lamina sandwiching a thick fat layer above the zygomatic bony arch. To characterize each lamina, their developmental processes were examined in fetuses. We observed histological sections from 22 half-heads of 10 mid-term fetuses at 14-18 weeks (crown-rump length, 95-150 mm) and 12 near-term fetuses at 26-40 weeks (crown-rump length, 215-334 mm). The superficial lamina of the temporal fascia was not evident at mid-term. Instead, a loose subcutaneous tissue was attached to the thin, deep lamina of the temporal fascia covering the temporalis muscle. At near-term, the deep lamina became thick, while the superficial lamina appeared and exhibited several variations: i) a mono-layered thick membrane (5 specimens); ii) a multi-layered membranous structure (6) and; iii) a cluster of independent thick fasciae each of which were separated by fatty tissues (1). In the second and third patterns, fatty tissue between the two laminae was likely to contain longitudinal fibrous bands in parallel with the deep lamina. Varying proportions of the multi-layered superficial lamina were not attached to the zygomatic arch, but extended below the bony arch. Whether or not lobulation or septation of fatty tissues was evident was not dependent on age. The deep lamina seemed to develop from the temporalis muscle depending on the muscle contraction. In contrast, the superficial lamina developed from subcutaneous collagenous bundles continuous to the cheek. Therein, a difference in development was clearly seen between two categories of the fasciae.

A Cephalometric study on tooth movement pattern of maxillary 6 anteriors with double keyhole loops (Double keyhole loop에 의한 상악 6전치의 후방견인시 치아이동양상에 관한 측모두부방사선계측학적 연구)

  • Kim, Hyun-Kyung;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.9-18
    • /
    • 2002
  • The present study hypothesized that the double keyhole looped archwire plays a positive role for the sake of translatory movement and/or controlled tipping of upper 6 anteriors, and secures anchorage control as well. The purposes of the study were to evaluate the changes in lateral cephalograms during orthodontic treatment with DKHLs and to compare the skeletal & dental changes before- & after-treatment. The materials of this study were lateral cephalograms of 20 adult patients with upper dentoalveolar protrusion both in class I and in class II Division1 malocclusion. Lateral cephalograms were taken before and after orthodontic treatment with upper 1st bicuspid extraction and DKHLs. The results were obtained as follows : 1. There were no statistically significant differences in skeletal measurement except SNB and PTFH between before- & after-treatment. The major changes were in dentoalveolar region. 2. After treatment, there were statistically significant decrease in dental measurement except interincisal angle. 3. Both upper & lower lip protrusion was decreased. 4. There were statistically differences in upper anterior crown horizontal & root vertical dimension(7.08 ${\pm}$ 2.14 mm, 2.38 ${\pm}$ 1.15 mm, p<0.01). 5. There were statistically differences in upper posterior dental(both crown & root) horizontal dimension(2.48 ${\pm}$ 0.99 mm, 2.05 ${\pm}$ 0.91 mm, p<0.01).

A study on the application of the aerial photographs for forest inventory (항공사진(航空寫眞)을 이용(利用)한 산림자원조사법(山林資源調査法)의 연구(硏究))

  • Kim, Kap Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 1976
  • This study was performed in Bo-Eun Gun, Chung-Cheong Buk Do. The forest types having been classified, the each area was measured by dot-grid method. The 820 sample points having been obtained by systematic sampling method, the tree heights, crown densities, crown diameters in the points were measured on the aerial photography, and the volumes per hectare were estimated by the comparison with stereogram. Thirty eight plots, which amounted to about 4.5% of all the sample points, were sampled with double sampling method and volume were measured by the ground survey method. the results were summarized as follows; 1. There is no significant differentia between the values measure by dot-grid method and the statistical values obtained by the authority for the area. 2. There is no significant differentia between the estimated values and the measured values for the volume. And the coefficient (b) was 1.18. 3. The heights of conifer trees were easily measured more or less, but it was some difficult for the deciduous trees, because the tops of trees were not observed easily. 4. All the values had a tendencies to be overestimated in the low stocked stand and to be underestimated in the high stocked stand. 5. When the aerial volume table method by ground checking needs to be used together, the work should be performed by the experienced technician and the photgraphic volume table should be made in advanced of the work.

  • PDF

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.