• Title/Summary/Keyword: Double crown

Search Result 77, Processing Time 0.03 seconds

EFFECT OF PRIMARY DOUBLE TEETH ON THE DEVELOPMENT OF PERMANENT SUCCESSORS (유치의 이중치와 계승영구치의 발육에 관한 연구)

  • Ra, Ji-Youn;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.136-143
    • /
    • 2004
  • The purpose of this study was to investigate the relationship between morphology and position of deciduous double teeth, and the occurrence of other dental anomalies in the same subject. Four morphological types were indentified according to Ailing's classification: type I, bifid crown-single root; type II, large crown-large root; type III, two fused crowns-single root; type IV, two fused crowns-two fused roots. Fifty-four double teeth were found in a total of 1,803 children, who had visited Wonkwang university hospital for dental treatment from January 1, 2003 to September 30, 2003. All of these children were examined clinically and intra-oral radiographs were taken. The results were as follows; 1. 49 children(2.7%) had more than one double teeth, 5 of these children had two double teeth on the bilateral side. And one child showed triple teeth which has three crowns and three roots. 2. Double teeth were predominantly situated in the anterior region, with a preference for the mandible. The ratio of cases involving central incisor and lateral incisor was higher than other cases. 3. There were 25 cases(46.2%) of missing successors among 54 cases of the double teeth. And, prevalence of the missing teeth was highest in the cases involving maxillary central incisor and lateral incisor. 4. In the case of type II(large crown-large root) had more missing successors.

  • PDF

Sprouting Condition of Crown Bud and Plug Seedling Production in Yacon

  • Doo, Hong-Soo;Choo, Byung-Kil;Ryu, Jeom-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.4
    • /
    • pp.223-227
    • /
    • 1998
  • The objectives of this study were to find the sprouting condition and to establish the optimum production methods of plug seedlings in yacon (Polymnia sonchifolia Poepp. & Endl.). The sprouting ratio was greatest at $30\pm 1^{\circ}C$ at 20 days after planting. Crowns with single buds were more effective than those with two or more buds for sprouting, which might be due to the apical dominance. Planting the shoots separated from crown after sprouting in the single- and double-layer polyethylene-covered greenhouses reduced seedling period with 25% and 50%, respectively. Planting the shoots after sprouting was more effective than planting the crown buds. Double-layer polyethylene-covered green-house was good for plug seedling production than open field or single-layer polyethylene-covered greenhouse. The bed soils composed of clay loam : compost or sand : compost (1:l=v:v) were more effective to produce plug seedlings than only clay loam, sand or compost. Seedlings could be produced at 30 days after planting in our studies.

  • PDF

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

Halogenation of Cannabinoids (Cannabinoid의 할로겐화)

  • Baek Seung-Hwa;Park No-Yeun
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.59-63
    • /
    • 1991
  • Several types of cannabinoids have been halogenated in the aromatic ring in good yields with metal halide in the presence of 18-crown-6 on oxidation with m-chloroperbenzoic acid. This reagent system effects the regiospecific halogenation of activated aromatic ring over olefinic double bond.

  • PDF

Halogenation of Resorcinol Derivatives

  • Baek Seung-Hwa
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.1
    • /
    • pp.13-15
    • /
    • 1988
  • Several types of resocinols have been monobrominated in the ring in good yields with sodium bromide in the presence of 18-crown-6 on oxidation with m-chloroperbenzoic acid. Monoiodination takes place with 2'-(1-methylcyclohexen-3-yl)-5-(1,1-dimethylheptyl )-resocinol when sodium iodide is employed. This new reagent system, MX/18-crown-6/m-CPBA (M =$K^+, Na^+, X = Br^-, I^-X$ ), effects the regiospecific halogenation of activated aromatic ring over olefinic double bond.

Prosthetic treatment for Down's syndrome patient with dental cross bite problem using maxillary double crown denture (교차교합을 가진 다운증후군 환자의 상악 이중관 의치를 이용한 수복 증례)

  • Doh, Seok-Joo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.81-87
    • /
    • 2019
  • Patients with Down's syndrome have several dental complications such as small teeth caused by underdevelopment of dentin and enamel, periodontitis, agenesis of teeth, prolonged retention of primary teeth and malocclusion due to narrow palate. Removable denture with maxillary double crowns would be a good treatment option to solve the problems of the patient with Down's syndrome. Double crowns compensate the insufficient support and retention of denture and easily solve the cross bite problem. Double crowns also allow easy repair of denture in case of abutment teeth extraction. In this case, 26-year-old female patient with Down's syndrome and dental phobia had small number of teeth with enamel hypoplasia, prolonged retention of primary teeth and dental cross bite. Prosthetic treatment was done using removable denture with double crowns in the maxilla. In the mandible, teeth preparation was done on enamel margin without anesthesia. Anterior laminate and posterior complete zirconia crown restorations were performed. As a result, the cross bite was effectively corrected by denture with double crowns. Pronunciation and appearance were also improved without extraction of teeth and dental anesthesia.

Prosthetic treatment for patient with upper lip cancer and severe periodontitis: Maxillary complete denture with denture adhesive and mandibular double crown-retained removable partial denture (구순암 환자에서의 의치접착제를 이용한 상악 총의치와 심한 치주 상태에서의 하악 이중관의치를 이용한 수복 증례)

  • Choi, Hyun-Suk;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.74-80
    • /
    • 2015
  • When oral cancer is occured, one may experience problems such as lip defect, necrosis of periodontal tissue and cervical caries caused by radiotherapy. According to ADI (Association of dental implantology), recent radiotherapy on jaw bone could be a relative contraindication of implant treatment. Due to this controversy, in most cases, treatment is done with removable dentures rather than implants. Especially, lip defect caused by an oral cancer operation have a serious repercussion on the retention of the denture. In this case report, patient with upper lip cancer had undergone resection primarily and secondary radiotherapy was done periodically. As a result, upper teeth of patient were extracted gradually and lower teeth showed very poor periodontal status. Therefore, Polident$^{(R)}$ denture adhesive cream (GlaxoSmithKline, London, England) was applied on maxillary complete denture to overcome reduced retention due to the lip defect and double crown RPD with friction pin was applied on the mandible successfully for two years.

Evaluation of Color Change According to Coloring Time of Dental Zirconia Block (치과용 지르코니아 블럭의 착색시간에 따른 색조변화 관찰)

  • Choi, Sung-Min;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.219-224
    • /
    • 2011
  • Purpose: The current study focused on investigating color change of dental zirconia block with respect to the block coloring time. Methods: Three types of dental zirconia blocks(Zirtooth, Pearl-HT, D-Max) were tinted with coloring agent under four different time condition (0 minutes, 1 minutes, 10 minutes, 30 minutes). The quantitative evaluation of the tinted dental zirconia blocks was conducted with spectrophotometer. Results: The Zirtooth and D-Max blocks showed lower H value. The Pearl-HT blocks showed poor reflectivity(L value). Conclusion: The study of color change of zirconia block, which consists the substructure of all ceramic Crown, is applicable for deciding appropriate coloring condition when fabricating one layer ceramic Crown or double layer ceramic Crown.

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.