• Title/Summary/Keyword: Double crown

Search Result 77, Processing Time 0.026 seconds

Causes of failed implant attachments and application of double crown implant overdenture in one patient (한 환자에서 실패한 임플란트 부착장치들의 원인과 이중관 임플란트 피개 의치의 적용)

  • Kwon, Jae-Uk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.368-374
    • /
    • 2018
  • In this case, the patient was restored with gold Hader bar mandibular implant overdenture using two implants about 10 years ago, and the retentive force was lost due to severe wear of the bar due to 3.5 years use. The overdenture was repaired using a Locator attachment, but the male part was completely worn after 6.5 years use. Finally, we used a hybrid telescopic double crown with a friction pin to fabricate a new implant overdenture, which was observed for 2 years and showed excellent prognosis. So, we describe the cause of failure of each attachment (Gold Hader bar, Locator) in two implant overdentures and report on the advantages and disadvantages of double crown implant overdenture and the conditions for success.

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

Wave Screening Performance of the Submerged Breakwater With Various Crown Widths (폭 변화에 따른 잠제의 파랑 차단 성능)

  • Cho Won Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.4
    • /
    • pp.206-212
    • /
    • 2004
  • The numerical analysis on the wave screening performance of the submerged breakwater with various crown widths is presented. The fluid motion is considered as linearized two dimensional potential flow and the finite element method is used to analyze the wave screening performance of the submerged breakwater. It is found that single-submerged breakwater with large crown width shows the most effective wave screening performance and single-submerged breakwater with small crown width also shows fairly good wave screening performance but its effectiveness is less than that of single-submerged breakwater with large crown width. However, double- or triple-submerged breakwater with small crown width shows more effective wave screening performance than that of single- or double-submerged breakwater with large crown width. It is expected that the submerged breakwater with small crown width is economical because it reduces the size of structure.

Prosthetic treatment for patient with congenital bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture (선천성 양측성 구순구개열 환자의 구비강 연결 폐쇄를 위한 상악 이중관과 고리 유지형 국소의치를 이용한 수복 증례)

  • Doh, Seok-Joo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.18-23
    • /
    • 2019
  • Patients with cleft lip and palate have several problems such as oro-nasal communication, dental cross-bite caused by the insufficient growth of maxilla, poor pronunciation and esthetic problem. Removable denture with maxillary double crown near cleft palate and with clasp in the posterior teeth was used to solve the problems of the patient with cleft lip and plate. Double crowns make up for the insufficient mucosal support caused by the mucosa and alveolar bone loss in cleft lip and palate. Double crowns also allow easy repair of denture in case of abutment teeth extraction. In this case, 55-year-old female patient had bilateral cleft lip and palate and few remaining teeth on anterior maxilla. Prosthetic treatment was done for patient with bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture. As a result, oro-nasal communication was effectively closed and the cross-bite was easily corrected by double crown and clasp retained denture. In addition, pronunciation and appearance were also improved.

MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY (Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구)

  • Jung, Hi-Chan;Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

Prosthetic rehabilitation for patient with hemi-maxillectomy: Obturator combined with a hybrid telescopic double crown using friction pin (편측 절제된 상악골 환자에서 하이브리드 텔레스코픽 이중관 의치를 이용한 구강 폐색기 수복 증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.317-323
    • /
    • 2018
  • When oral cancer develops in the maxilla, oro-nasal communication occurs after surgical treatment including removal of the primary site. Restoration through an obturator is necessary to prevent food from storing due to non-oral opening, and to ensure proper pronunciation and aesthetic restoration. In this case, the patient was treated with right hemi-maxillectomy due to oral cancer and has residual abutment and poor periodontal support due to the effect of head and neck radiotherapy. The obturator was treated with a hybrid telescopic double crown denture. Reporting a successful prognosis in 18 months of follow-up.

Prosthetic restoration of a partially edentulous patient using double crowns: a clinical report (이중관을 이용한 부분 무치악 환자의 수복 증례)

  • Park, Minseo;Kim, Hyeong-Seob;Kwon, Kung-Rock;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • In removable dental prostheses, it is important to minimize impairment of residual tissue caused by wearing dentures. There are two factors that harm residual tissue. The first is functional load bearing of remaining teeth and alveolar ridges and the second is the effect of poor oral hygiene. Double crown retained removable dental prostheses provide rigid support, and it may reduce impairment caused by load bearing of alveolar ridges. Also, dental plaque and oral deposits, which are attached to outer crowns and dentures, can be easily managed extra-orally. In addition, it is beneficial to the health of the marginal gingiva because inner crowns have easy access for oral hygiene. In this case, double crown retained removable dental prostheses were used for the partially edentulous patient with severe residual alveolar bone resorption and poor oral hygiene, and the result was clinically satisfactory in terms of functional, esthetical, and oral hygiene aspects.

DEGREE OF CONVERSION OF BIS-ACRYLIC BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Kim, Sung-Hun;Watts, David C.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.639-643
    • /
    • 2008
  • STATEMENT OF PROBLEM: The degree of conversion may influence the ultimate mechanical and physical properties of provisional crown and fixed partial denture materials. The high levels of the unreacted residual monomer may cause deleterious effect on the properties. PURPOSE: The purpose of this study was to measure the degree of conversion of bis-acrylic based provisional crown and fixed partial denture materials by using an infrared spectroscopic method. MATERIAL AND METHODS: Chemically activated three bis-acrylic based provisional crown and fixed partial denture materials, LuxaTemp [DMG, Hamburg, Germany], fast set TemPhase [Kerr, Orange, CA, USA] and Protemp 3 Garant [3M-ESPE, St Paul, MN, USA], were investigated by Fourier transform infrared spectrometry (FTIR). The FTIR spectra of the materials tested were immediately obtained after mixing. The specimens were stored under dry conditions and at $23^{\circ}C$ for 24 hours, and then the spectra of the materials were also obtained. The degree of conversion (%) was calculated from the spectrum of the absorbance between the aliphatic double bond at 1637 $cm^{-1}$ and the aromatic double bond at 1608 $cm^{-1}$ using the baseline method. The data were statistically analyzed using one-way ANOVA and the multiple comparison Scheffe test at the significance level of 0.05. RESULTS: The mean value and standard deviation of the degree of conversion were 52.5 % ${\pm}$ 1.1 %, 50.3 % ${\pm}$ 0.8 %, and 42.3 % ${\pm}$ 4.9 % for LuxaTemp, Protemp 3 Garant and fast set TemPhase, respectively. There was no significant difference between LuxaTemp and Protemp 3 Garant, whereas there was a statistically difference between Protemp 3 Garant and fast set TemPhase, and LuxaTemp and fast set TemPhase (P < .05). CONCLUSION: The degree of conversion of fast set TemPhase was significantly lower than those of the others. The degree of conversion may be correlated with the rate of polymerization.