• Title/Summary/Keyword: Double Sound

Search Result 143, Processing Time 0.031 seconds

Sensitivity Analysis for Railway Development Areas Using Land Cover Map (토지피복지도를 활용한 철도개발지의 민감도 분석)

  • Kim, Min-Kyeong;Kim, Dong-Yoeb
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.76-84
    • /
    • 2017
  • Recently, the 'Ecological Network Restoration Project at Chupungnyeong' has been placed; this project is located at the center of the Baekdu mountain spine, the core of the ecological network of the Korean Peninsula. In the process of industrialization since the early 1900s, this area has been under railroad and road construction; as such, wildlife movements have been interrupted and many cases of road-kill have been found. The investment in railroads has increased because railroads are an environmentally sound means of transportation. Single track railways have been converted to double track electric railways and track reforming projects are underway in order to speed up the current railway system. This study suggests to take land use as a standard for assessing the ecological weaknesses of the domestic geo-spaces that are to be affected by rapid extension of railway lines. The land cover map issued by the Ministry of Environment was overlapped with the Korean Railway Line Map for analysis. The results showed that five items were high in sensitivity: paddy fields, fields, deciduous forests, bare land, and inland waters. It seems to be necessary to set weights for highly sensitive land use types; also, specific evaluation criteria need to be reestablished.

A retrospective clinical study of isolated patent ductus arteriosus (동맥관 개존증의 임상적 고찰)

  • 곽영태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.593-606
    • /
    • 1984
  • With the ligation of patent ductus arteriosus by Gross in 1938, surgeons first entered the field of congenital heart disease. Interruption of a ductus is one of the most satisfactory and curative operations in the field of surgery for congenital heart disease. 27 cases of isolated patent ductus arteriosus were operated from Jan. 1978 to July 1984 at the Department of Thoracic & Cardiovascular Surgery in Kyung-Hee University Hospital. Retrospective clinical analysis of these patients were: 1. Sex ratio, female: male, was 2:1. 2. Mean age at operation was 9.85\ulcorner.58 years. The youngest patient was a 23 month-old girl and the oldest one was a 24 year-old male. 3. More than half of the patients had less than 50 percentile of growth retardation. 4. Chief complaints of the patients were frequent URI [52%], dyspnea on exertion [33%], generalized weakness [22%], palpitation [7%], but 7 patients [26%] had no subjective symptoms. 5. Continuous machinery murmur could be heard at the 2nd or 3rd intercostal space on the left sternal border in 22 patients [81%]. The other S patients made systolic murmur with accentuation of the second heart sound and those were associated with pulmonary hypertension. 6. Radiologic findings of Chest P-A were cardiac enlargement in 15 patients [55%], enlargement of pulmonary conus and/or increasing density of pulmonary vascularity in 20 patients [74%]. 7. Electrocardiographic findings of the patients were within normal limit in 13 patients [48%], LVH in 4 patients [15%], biventricular hypertrophy in 3 patients [11%]. 8; echocardiogram was obtained from 11 patients. Ductus was directly visualized in 7 patients. Left atrial enlargement is the secondary change of left to right shunt, 10 patients had LA/Ao ratio more than 1.2. 9. Cardiac catheterization performed in 25 patients. The mean value of the results were:SO2[PA-RV]= 14.72\ulcorner6.01%, Qp/Qs=2.22\ulcorner.80, peak systolic pulmonary arterial pressure=48.28\ulcorner1.60 mmHg. 10. 26 patients were operated through the left posterolateral thoracotomy: closure of ductus by double ligation in 14 cases, triple ligation in 5 cases, and division with suture in 8 cases. One patient suffer from aneurysmal rupture of main pulmonary artery, endocarditis, hemopericardium was treated with cardiopulmonary bypass via median sternotomy and closure of ductus through the ruptured main pulmonary artery. 11.There was no death associated with the operation, but 3 cases were experienced with intraoperative rupture around the ductus resulting in massive bleeding. The other complications were transient hoarseness in one patient, atelectasis in left lower lobe in 3 patients, and postoperative systemic hypertension in 4 patients with unknown etiology. 12. Pulse pressure was reduced, 11.47+5.92 mmHg, postoperatively, as compare to preoperative status. 13. Intraoperative wedge lung biopsy from lingular segment for the evaluation of the pulmonary vascular disease was taken in S patients with severe pulmonary hypertension. The result was Heath-Edward grade I in one case, grade II in two cases, and grade III in two cases.

  • PDF

The Study of the Validity Test on the Self-monitoring Scale (자기 검색척도(Self-Monitoring Scale)의 타당성 검정에 관한 연구)

  • 이선아
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.751-759
    • /
    • 1998
  • The study of the validity test on the self-monitoring scale for nurses In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of the self-monitoring scale. The self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen(1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity were found in the previous research findings. It is also important to note that Snyder's self-monitoring scale did not factor-load at over. 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lacks convergent validity as the sub-factors of the scale failed to prove its uni-dimensionality. The A self-monit oring scale not only fail to overcome the problems of Snyder's self-monitori ng scale but even lost the attractiveness of the self-monitoring scale. In this study it was also found that the A self-monitoring scale was not classified in either in a two or three-factor classification as hypothesized. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used and has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were class ified and loaded as expected. Reliability was also proven by checking Cronbach's α for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound : however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original nor the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over. 30, too high for the two factors in the test results of Factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Study of the Validity Test on the Self-monitoring Scale for Primi-Gravida (초임부를 대상으로 한 자가검색도 척도의 타당도 비교)

  • Lee, Seon-Ah
    • Women's Health Nursing
    • /
    • v.4 no.2
    • /
    • pp.173-186
    • /
    • 1998
  • In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen (1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity was found in the previous research findings. It is also important to note that Snyder's self-monitoring scale, did not factor-load at over 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lack convergent validity as the sub-factors of the scale fail to prove its uni-dimensionality. The A self-monitoring scale not only fail to overcome the problems of Snyder's self-monitoring scale but even lost the attractiveness of the self-monitoring scale. In this study, it was also found that the A self-monitoring scale was not classified as hypothesized in either in a two or three-factor classification. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used but also has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study 1. was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were classified and loaded as expected. Reliability was also proven by checking Cronbach's alpha for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound ; however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original or the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over .30, too high for the two factors in the test results of factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.

Design and Implementation of NMEA Multiplexer in the Optimized Queue (최적화된 큐에서의 NMEA 멀티플렉서의 설계 및 구현)

  • Kim Chang-Soo;Jung Sung-Hun;Yim Jae-Hong
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.91-96
    • /
    • 2005
  • The National Marine Electronics Association(NMEA) is nonprofit-making cooperation composed with manufacturers, distributors, wholesalers and educational institutions. We use the basic port of equipment in order to process the signal from NMEA signal using equipment. When we don't have enough one, we use the multi-port for processing. However, we need to have module development simulation which could multiplex and provide NMEA related signal that we could solve the problems in multi-port application and exclusive equipment generation for a number of signal. For now, we don't have any case or product using NMEA multiplexer so that we import expensive foreign equipment or embody NMEA signal transmission program like software, using multi-port. These have problems since we have to pay lots ci money and build separate processing part for every application programs. Besides, every equipment generating NMEA signal are from different manufactures and have different platform so that it could cause double waste and loss of recourse. For making up for it, I suggest the NMEA multiplexer embodiment, which could independently move by reliable process and high performance single hardware module, improve the memory efficiency of module by designing the optimized Queue, and keep having reliability for realtime communication among the equipment such as main input sensor equipment Gyrocompass, Echo-sound, and GPS.

A Study of the noise level in hospital and the Count-Measure against the noise (병실내 소음도와 환자와의 관계)

  • Kim, Myung-Ho;Cha, Il-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 1973
  • In this study noise source in a ward at four general hospitals in Seoul area has been investigated and analysed. The degree of reaction against noise by 171 randomly has also been examined. The results of the study have shown that the source of noise is the speakers of wired broadcasting or from visiting guests in two hospitals located in residential area. The patients at the two other hospitals located at commercial site have been suffered more from traffic noise. However, because of their separated living at hospital from their ordinary houselife, sixty one percent of the inpatients have wished a music sound of around 60 dB (A). After having considered the results of the investigation and wishes of the inpatients, following suggestions have been made: 1. Reduce the number of guests or their length of stay. 2. Wired broadcasting system should be substitued by wireless one, or if it's unavoidable, it should be used in office rooms only. 3. Since the stops and starts of vehicles induce much noise, Seoul City Government be requested to prepare an appropriate administrative measure for the vehicles around hospital area and it should prevent the establishment of new hospitals along high way site. 4. By using earphone, inpatients can choose a wireless channel according to each individual's taste. This through the masking effect, would cover up the noise source. 5. Rooms along the streets should be utilized as offices, otherwise double windows should be set up for inpatient's wards.

  • PDF

Prospects of Stable Production Technologies for Food Crops (식량 안정생산기술의 전망)

  • Chae Je Cheon;Gang Yang Sun;Lee Yeong Ho;Nam Jung Hyeon
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 1999.11a
    • /
    • pp.102-144
    • /
    • 1999
  • The major problems of food crop cultivation in Korea are low yield of most crops except rice. inefficient cultivation techniques for aged farmers. and low international competibility. Therefore, development of cultivation techniques of food crops should aim the yield. quality improvement, labor reduction and production cost. The primary issue for increasing the yield of soybean, barely and wheat is to reduce the yield gap between the farmer's yield and recommended ones of experiment station. More advanced cultivation techniques needs to be developed. and/or the conventional breeding methods to be reconsidered. The newly developed labor-saving mechanized technique needs to reduce labor hours , and the cost of agricultural implements and machineries. In other words the labor-saving mechanized technique should be developed based on the improvement of total farming system as well as systemic fundamental innovation of cultural methods. The efficiency of solar energy use in food production of Korea in 1997 is as low as $0.52{\%}$ so there is much room to increase yield. It is recommendable that the concept of food Production should be changed to energy Producing efficiency Per unit area basis from volume and weight of food materials. Moreover, introduction of resonable cropping system is needed to increase yield of main crops, farmer's income, solar energy use efficiency, and decrease of land service expenditure. Current cropping system emphasized on economic crops. especially in vegetables , is not desirable for resonable use of arable land. stability of agricultural management and staple food crop self-sufficiency ratio. It is desirable to increase food crops . that are energy of carbohydrate and protein rich and land dependent crops. in cropping system. And the agronomist should develop the cultural methods to replace food crops for food self-sufficiency and stable farming management instead of economic crops in current cropping system. Low-input and environmentally-sound crop cultivation techniques, especially nitrogen-reducing culture technique which is directly related to food crop quality, also needs to be developed urgently. The extended cultivation of corn in upland and barely and wheat in lowland as a feed stuffs is recommended to prevent further decrease of food self-sufficiency ratio, which is mainly caused by the high reliance on imported feed grain. It is also considered that the calculation and presentation methods of standard agricultural income needs to be improved. The current calculation method uses unit land area of 10a regardless of crop kinds , characteristics of agricultural management and cultivation scale. So, it is apt to lead misunderstanding of farm income value. Therefore. it should show an income of average farmers for certain number of years. Research and developing system for food producing is not desirable because they are conducted currently individual crop and mono-culture basis. But actual agricultural income is usually earned by cropping system including upland and lowland. For example. the barley and wheat is usually cultivated in double cropping system. The cooperation among research institutes such as university agribusiness. government and farmers is indispensible. The public information and education on importance and consumption habit of food crops is necessary in Korean society to increase food self-sufficiency through nationwide cooperation.

  • PDF

Mock-up Test of Improved Concrete Binders for Lightweight Foamed concrete (경량기포 콘크리트용 개량분체의 Mock-up 실험평가)

  • Choi, Sung-Yong;Jeong, Kwang-Bok;Kim, Gi-Cheol;Kim, Seong-Soo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.853-856
    • /
    • 2008
  • Lightweight foamed concretes are mainly used in apartment building construction for building room floor insulation, sound proof and height difference adjustment, etc. However, existing lightweight foamed concretes have problems like volume reduction by foam removal and excessive crack occurrence, etc, and for compensation, they developed improved concrete binders for lightweight foamed concrete with special characteristics by adding admixture materials used in concrete manufacturing. Therefore, this study reviewed the possibility of its practical use by analyzing all the engineering characteristics after producing imitation member proposed as actual binders and piling lightweight foamed concrete as improved lightweight foamed concrete binder through prior study, the results are as follows. Plain in which various pulverulent materials are mixed showed about 230mm of flow value, satisfying the target flow value, and at 100mm member, about 4mm of settlement occurred, showing a settlement depth reduction effect double the OPC. On strength, OPC showed highest value, but the three levels all showed strengths above the specified value of KS standard 0.5 grade. From the analysis of drying shrinkage member crack, plain, about 0.1mm, was shown very excellent against drying shrinkage crack.

  • PDF

Acoustic characteristics of sound field in partially opened rooms - Emphasis on horizontal coupling of diffuse and non-diffuse field - (실내공간의 부분적 개방에 따른 음향특성변화 I - 확산음장과 자유음장의 수평적 결합을 중심으로 -)

  • Jeong, Dae-Up;Choi, Young-Ji;Kim, Ji-Young;Oh, Yang-Ki;Choi, Seok-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.105-114
    • /
    • 2007
  • Large span spaces have been widely used for various purposes including sports events in other countries. Due to increasing demands on multi-purpose use of such spaces, recently built large span sport facilities such dome stadiums have been required to accommodate sport events as well as performing events. Also, retractable ceilings and/or walls were generally adopted in those spaces for providing various event conditions. It seems obvious that the openings between diffuse fields and free field may cause difficulties in the acoustic design of such spaces In the present work, the acoustic characteristics of non-diffuse field has been investigated using 1/10 acoustic scale models. It was found that RTs at low- and mid-frequencies decayed faster than those at high-frequencies as the percentage of opening area increased. The decay rate of RTs at high frequencies were not influenced by increasing the area of an opening. Also high dependence of EDT on the percentage of opening area was observed at all frequency range. D50 was not improved by increasing the area of an opening up to 12.5% and then sharply increased. The application of Schroeder integration to evaluate the reverberation charateristics of coupled spaces may not be proper, since non-exponential decay process with double or triple decays of those spaces can not be properly defined. EDT seems more appropriate to predict reverberation at the early acoustic design stage of acoustically coupled spaces.

  • PDF