• 제목/요약/키워드: Double Ridge

검색결과 41건 처리시간 0.024초

Alveolar ridge preservation with an open-healing approach using single-layer or double-layer coverage with collagen membranes

  • Choi, Ho-Keun;Cho, Hag-Yeon;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Koo, Ki-Tae;Lim, Hyun-Chang;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제47권6호
    • /
    • pp.372-380
    • /
    • 2017
  • Purpose: The aim of this prospective pilot study was to compare alveolar ridge preservation (ARP) procedures with open-healing approach using a single-layer and a double-layer coverage with collagen membranes using radiographic and clinical analyses. Methods: Eleven molars from 9 healthy patients requiring extraction of the maxillary or mandibular posterior teeth were included and allocated into 2 groups. After tooth extraction, deproteinized bovine bone mineral mixed with 10% collagen was grafted into the socket and covered either with a double-layer of resorbable non-cross-linked collagen membranes (DL group, n=6) or with a single-layer (SL group, n=5). Primary closure was not obtained. Cone-beam computed tomography images were taken immediately after the ARP procedure and after a healing period of 4 months before implant placement. Radiographic measurements were made of the width and height changes of the alveolar ridge. Results: All sites healed without any complications, and dental implants were placed at all operated sites with acceptable initial stability. The measurements showed that the reductions in width at the level 1 mm apical from the alveolar crest (including the bone graft) were $-1.7{\pm}0.5mm$ in the SL group and $-1.8{\pm}0.4mm$ in the DL group, and the horizontal changes in the other areas were also similar in the DL and SL groups. The reductions in height were also comparable between groups. Conclusions: Within the limitations of this study, single-layer and double-layer coverage with collagen membranes after ARP failed to show substantial differences in the preservation of horizontal or vertical dimensions or in clinical healing. Thus, both approaches seem to be suitable for open-healing ridge preservation procedures.

Sphenoid Ridge Meningioma Presenting as Acute Cerebral Infarction

  • Ko, Jun Kyeung;Cha, Seung Heon;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권2호
    • /
    • pp.99-102
    • /
    • 2014
  • A previously healthy 52-year-old man presented to the emergency room with acute onset left hemiparesis and dysarthria. Brain computed tomography and magnetic resonance examinations revealed acute cerebral infarction in the right middle cerebral artery territory and a sphenoid ridge meningioma encasing the right carotid artery terminus. Cerebral angiography demonstrated complete occlusion of the right proximal M1 portion. A computed tomography perfusion study showed a wide area of perfusion-diffusion mismatch. Over the ensuing 48 hours, left sided weakness deteriorated despite medical treatment. Emergency extracranial-intracranial bypass was performed using a double-barrel technique, leaving the tumor as it was, and subsequently his neurological function was improved dramatically. We present a rare case of sphenoid ridge meningioma causing acute cerebral infarction as a result of middle cerebral artery compression.

Double crown retained RPD의 4년 임상 관찰 (DOUBLE CROWN RETAINED REMOVABLE PARTIAL DENTURE - 4 YEARS IN RETROSPECT)

  • 이석형
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.73-82
    • /
    • 2004
  • Statment of problem : Little in known about the importance of selection of various double crowns as retainer in determining the outcome of treatment with double crown retained removable partial denture. Purpose : To obtain information about the effects and the results of this treatment modality. Material and methods : This study describes 61 double crown retained removable partial dentures worn by 51 patients from Samsung Medical Center, Seoul a time ranging between 6 and 48 months and evaluate occlusal contacts on the denture teeth, denture movement, incidence of denture relining, denture retention, fracture of dentures and abutments, hygiene, residual ridge inflammatory changes, number of lost abutment,. interruption of denture use. Results : One tenth of all the restorations were relined. Restorations in 21 arches fractured repeatedly for various reasons . There was no apparent interrelationship between fractures and the five groups. Conclusion : Good prognoses of removable partial dentures were shown in all groups(Kennedy Classes I, II, III, combination and few remaining abutment).

A comparison of different compressive forces on graft materials during alveolar ridge preservation

  • Cho, In-Woo;Park, Jung-Chul;Shin, Hyun-Seung
    • Journal of Periodontal and Implant Science
    • /
    • 제47권1호
    • /
    • pp.51-63
    • /
    • 2017
  • Purpose: Following tooth extraction, alveolar ridge preservation (ARP) can maintain the dimensions of ridge height and width. Although previous studies have demonstrated the effects of ARP, few if any studies have investigated the compressive force applied during grafting. The aim of this study was to determine the effects of different compressive forces on the graft materials during ARP. Methods: After tooth extraction, sockets were filled with deproteinized bovine bone mineral with 10% porcine collagen and covered by a resorbable collagen membrane in a double-layered fashion. The graft materials were compressed using a force of 5 N in the test group (n=12) and a force of 30 N in the control group (n=12). A hidden X suture was performed to secure the graft without primary closure. Cone-beam computed tomography (CBCT) was performed immediately after grafting and 4 months later, just before implant surgery. Tissue samples were retrieved using a trephine bur from the grafted sites during implant surgery for histologic and histomorphometric evaluations. Periotest values (PTVs) were measured to assess the initial stability of the dental implants. Results: Four patients dropped out from the control group and 20 patients finished the study. Both groups healed without any complications. The CBCT measurements showed that the ridge volume was comparably preserved vertically and horizontally in both groups (P>0.05). Histomorphometric analysis demonstrated that the ratio of new bone formation was significantly greater in the test group (P<0.05). The PTVs showed no significant differences between the 2 groups (P>0.05). Conclusions: The application of a greater compressive force on biomaterials during ARP significantly enhanced new bone formation while preserving the horizontal and vertical dimensions of the alveolar ridge. Further studies are required to identity the optimal compressive force for ARP.

Comparative, randomized, double-blind clinical study of alveolar ridge preservation using an extracellular matrix-based dental resorbable membrane in the extraction socket

  • Chang, Hyeyoon;Kim, Sulhee;Hwang, Jin wook;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Lee, Jong-Ho;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제47권3호
    • /
    • pp.165-173
    • /
    • 2017
  • Purpose: The aim of this study was to radiographically and clinically compare the effect of extracellular matrix (ECM) membranes on dimensional alterations following a ridge preservation procedure. Methods: One of 2 different ECM membranes was applied during a ridge preservation procedure. A widely used ECM membrane (WEM; Bio-Gide, Geistlich Biomaterials, Wolhusen, Switzerland) was applied in the treatment group and a newly developed ECM membrane (NEM; Lyso-Gide, Oscotec Inc., Seongnam, Korea) was applied in the control group. Cone-beam computed tomography (CBCT) scans and alginate impressions were obtained 1 week and 6 months after the ridge preservation procedure. Results were analyzed using the independent t-test and the nonparametric Mann-Whitney U test. Results: There were no significant differences between the ECM membranes in the changes in the dimension, width, and height of the extraction socket or the quantity of bone tissue. Conclusions: The NEM showed comparable clinical and radiographic results to the WEM following the ridge preservation procedure.

Theoretical and Experimental Investigation on the Probe Design of a Ridge-loaded Slot Type for Near-Field Scanning Microwave Microscope

  • Son, Hyeok-Woo;Kim, Byung-Mun;Hong, Jae-Pyo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2120-2125
    • /
    • 2015
  • In this paper, a rectangular waveguide probe with a ridge-loaded straight slot (RLSS) is presented for a near-field scanning microwave microscope (NSMM). The RLSS is located laterally at the end wall of the cavity and is loaded on double ridges in a narrow straight slot to improve the spatial resolution compared with a straight slot. The probe consists of a rectangular cavity with an RLSS and a feed section of a WR-90 rectangular waveguide. When the proposed NSMM is located at distance of 0.1mm in front of a substrate without patches or strips, the simulated full width at half maximum (FWHM) of the probe improve by approximately 31.5 % compared with that of a straight slot without ridges. One dimensional scanning of the E-plane on a sample under test was conducted, and the reflection coefficient of the near-field scanning probe is presented.

Axial load prediction in double-skinned profiled steel composite walls using machine learning

  • G., Muthumari G;P. Vincent
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.739-754
    • /
    • 2024
  • This study presents an innovative AI-driven approach to assess the ultimate axial load in Double-Skinned Profiled Steel sheet Composite Walls (DPSCWs). Utilizing a dataset of 80 entries, seven input parameters were employed, and various AI techniques, including Linear Regression, Polynomial Regression, Support Vector Regression, Decision Tree Regression, Decision Tree with AdaBoost Regression, Random Forest Regression, Gradient Boost Regression Tree, Elastic Net Regression, Ridge Regression, and LASSO Regression, were evaluated. Decision Tree Regression and Random Forest Regression emerged as the most accurate models. The top three performing models were integrated into a hybrid approach, excelling in accurately estimating DPSCWs' ultimate axial load. This adaptable hybrid model outperforms traditional methods, reducing errors in complex scenarios. The validated Artificial Neural Network (ANN) model showcases less than 1% error, enhancing reliability. Correlation analysis highlights robust predictions, emphasizing the importance of steel sheet thickness. The study contributes insights for predicting DPSCW strength in civil engineering, suggesting optimization and database expansion. The research advances precise load capacity estimation, empowering engineers to enhance construction safety and explore further machine learning applications in structural engineering.

국소의치상을 위한 연성 이장재사용시 교합압에 따른 의치상 변위(Displacement)량 비교 (A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.18-25
    • /
    • 1998
  • The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge and thickness of soft relining material under masticatory force. Stone models that simulated residual ridge were made with different amount of denture base area and denture was fabricated by conventional heat curing resin with usual manner on the model and relined by silicone type soft relining material with different thickness. Specimen was examined the amount of denture displacement by Instron within range of normal occlusal force. The results were as following : 1. The increasing rate of denture displacement was higher than that of soft relining material thickness. 2. The amount of denture displacement decreased 1.7 times when base area became double at same thickness of soft relining material 3. The increasing rate of denture displacement was higher than that of occlusal force

  • PDF

A Ridge-type Silicon Waveguide Optical Modulator Based on Graphene and Black Phosphorus Heterojunction

  • Zhenglei Zhou;Jianhua Li;Desheng Yin;Xing Chen
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.399-405
    • /
    • 2024
  • In this paper, an optical modulator based on monolayer graphene and triple-layer black phosphorus (BP) heterojunction in the optical communication band range is designed. The influences of geometric parameters, chemical potential, BP orientation and dispersion on the fundamental mode of this modulator were determined in detail by the finite-difference time-domain (FDTD) method. Using appropriate geometric parameter settings, the extinction ratio of this proposed modulator is 0.166 dB, while the modulator with a working length of 3 ㎛ can realize a 0.498 dB modulation depth. The 3-dB bandwidth of this modulator could achieve up to 2.65 GHz with 27.23 fJ/bit energy consumption. The extinction ratio and bandwidth of the proposed modulator increased by 66% and 120.83%, respectively, compared to the monolayer graphene-based ridge-type waveguide modulator. Energy consumption was reduced by 97.28%, compared to a double-layer graphene-based modulator.

L자형 루프를 이용한 광대역 동축-이중릿지도파관 변환기 (Broadband Coaxial-to-Double Ridge Waveguide Transformer Using L-shape Loop)

  • 김진형;김준태;박동철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.198-201
    • /
    • 2001
  • L자형 루프를 이용하여 주파수대역이 6-18 GHz인 동축-이중릿지도파관 변환기를 상용 소프트웨어인 HFSS를 이용하여 설계한 후 제작하였다. L자형 루프는 동축-구형도파관 변환기에 이미 이용되고 있는 구조로써, 이를 동축-이중릿지도파관 변환기에 적용한 것이다. 제작 후 측정결과 대역폭이 6-18 GHz로 3:1 이상을 만족하며, 최대 삽입손실이 -1.52 dB 이었다.

  • PDF