• Title/Summary/Keyword: Double Plug

Search Result 19, Processing Time 0.022 seconds

Double Bypass of Esophagus and Descending Thoracic Aorta for the Treatment of Esophagapleural and Aortopleural Fistula (식도파열 후 발생한 식도 흉막루와 대동맥루의 수술적 치료: 식도 및 대동맥 이중 우회술)

  • Park, Sung-Joon;Kang, Chang-Hyun;Kim, Kyung-Hwan;Yao, Byung-Su;Kim, Young-Tae;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.753-757
    • /
    • 2010
  • We report hereon a case of double bypass of the esophagus and descending thoracic aorta for the treatment of esophagopleural fistula and aortopleural fistula due to an infected aortic aneurysm after esophageal rupture. A 48 year old man was diagnosed as having esophageal rupture after an accidental explosion. Although he had been treated by esophageal repair and drainage at another hospital, the esophageal leakage could not be controlled and subsequent empyema developed in the left pleura. Further, bleeding from the descending thoracic aorta had developed and he was managed with endovascular stent insertion to the descending thoracic aorta. He was transferred to our hospital for corrective surgery. We performed esophago - gastrostomy via the substernal route, without exploring posterior mediastinum and we let the empyema resolve spontaneously. While he was being managed postoperatively Without any signs and symptoms of infection, sudden bleeding developed from the left pleural cavity. After evaluation for the bleeding focus, we discovered an Infected aortic aneurysm and an aortospleural fistula at the stent insertion site. We performed a second bypass procedure for the infected descending thoracic aorta from the ascending aorta to the descending abdominal aorta via the right pleural cavity. We found leakage at the distalligation site during the immediate postoperative period, and we occluded the leakage using a vascular plug. He discharged without complications and he is currently doing well without any more bleeding or other complications.

Mid to Long - Term Results of Meniscal Allograft Transplantation (동종 반월상 연골 이식술 후 중장기 추시 결과)

  • Chun, Churl-Hong;Kweon, Seok-Hyun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: We report mid to long - term results of meniscal transplantation and evaluate the important factors for successful outcomes. Materials and Methods: Between December 1999 and September 2002, 25 meniscal transplantations were performed using fresh frozen allograft. The lateral meniscus was transplanted in 19 cases and medial meniscus in 6 cases. The mean age was 34 years (range, 17~50 years) and the mean follow up was 54.8 months (range, 6~85 months). Preoperative measurements were made using a ruler graded in millimeters. Lateral meniscus was fixed by keyhole technique and medial meniscus was fixed by double bone plug technique with suturing the periphery of the meniscal transplant. All patients were evaluated with Knee Assessment Scoring System (KASS), Lysholm knee score, and Tegner activity scale for daily activity. Results: Symptoms improved in all cases. The average KASS score increased from 61.7 preoperatively to 83.8 postoperatively. The average Lysholm knee score increased from 77.7 preoperatively to 87.7 postoperatively (excellent in 3 cases, good in 17 cases, fair 4 cases, poor 1 case). But painful swellings were 3 cases, numbness in 1 case, and granuloma due to non-absorbable suture material in 1 case. Peroneal nerve palsy in 1 case was recovered after 6 weeks postoperatively. Conclusion: Meniscal allograft transplantation after subtotal or total menisectomy can significantly relieve pain and improve function of the knee joint. The exact preoperative sizing and secure fixation are essential for successful outcomes.

  • PDF

Disinfection Models to Predict Inactivation of Artemia sp. via Physicochemical Treatment Processes (물리·화학적 처리공정을 이용한 Artemia sp. 불활성화 예측을 위한 소독 모델)

  • Zheng, Chang;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.421-432
    • /
    • 2017
  • In this study, we examined the suitability of ten disinfection models for predicting the inactivation of Artemia sp. via single or combined physical and chemical treatments. The effect of Hydraulic Retention Time (HRT) on the inactivation of Artemia sp. was examined experimentally. Disinfection models were fitted to the experimental data by using the GInaFiT plug-in for Microsoft Excel. The inactivation model were evaluated on the basis of RMSE (Root Mean Square Error), SSE (mean Sum Square Error) and $r^2$. An inactivation model with the lowest RMSE, SSE and $r^2$ close to 1 was considered the best. The Weibull+Tail model was found to be the most appropriate for predicting the inactivation of Artemia sp. via electrolytic treatment and electrolytic-ultrasonic combined treatment. The Log-linear+Tail model was the most appropriate for modeling inactivation via homogenization and combined electrolytic-homogenization treatment. The double Weibull disinfection model was the most suitable for the predicting inactivation via ultrasonic treatment.

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

Containment Evaluation of the KN-12 Transport Cask

  • Chung, Sung-Hwan;Choi, Byung-Il;Lee, Heung-Young;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • The KN-12 transport cask has been designed to transport 12 PWR spent nuclear fuel assemblies and to comply with the regulatory requirements for a Type B(U) package. The containment boundary of the cask is defined by a cask body, a cask lid, lid bolts with nuts, O-ring seals and a bolted closure lid. The containment vessel for the cask consists of a forged thick-walled carbon steel cylindrical body with an integrally-welded carbon steel bottom and is closed by a lid made of stainless steel, which is fastened to the cask body by lid bolts with nuts and sealed by double elastomer O-rings. In the cask lid an opening is closed by a plug with an O-ring seal and covered by the bolted closure lid sealed with an O-ring. The cask must maintain a radioactivity release rate of not more than the regulatory limit for normal transport conditions and for hypothetical accident conditions, as required by the related regulations. The containment requirements of the cask are satisfied by maintaining a maximum air reference leak rate of $2.7{\times}10^{-4}ref.cm^3s^{-1}$ or a helium leak rate of $3.3{\times}10^{-4}cm^3s^{-1}$ for normal transport conditions and for hypothetical accident conditions.

Analysis of Working Capacity of a Hand-fed Transplanter (반자동정식기 작업 성능 분석)

  • 문성동;민영봉;박중춘
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.159-167
    • /
    • 1997
  • To cope with the mass-production and supply of plug seedling, the supply of transplanters is necessary. In the study, a transplanting test was carried out to find the optimum working condition in the mechanizd transplantation and to acquire the basic data for the improvement of transplanters by the research and analysis of working capacity of the local manual transplanters. The size of hopper affected transplanting stand and rate. Re-irrigation was required for the transplanted seedlings because they wilt 1 day after the transplanting if soil compaction is incomplete. Consequently, back-forth-left-right compaction method was good for soil covering and compaction. It may be thought to increase the amount of irrigation water at the time of transplanting by double-irrigation mechanism, but it needs to increase the larger water tank which makes the operation uneasy. So, assuming the working model by 1 or 2 operators with the machine size as small as possible, it seemed that eliminating of automatic irrigation method was desirable in view of efficiency. Though semiautomatic transplanter needs some structural improvements, it seemed still suitable for transplanting of plug seedlings such as 45-day red pepper seedlings in 128-hole tray and 25-day Chinese cabbage seedling in 128-hole tray. If traveling speed of the transplanter is limited to less than 14 m/min, with the transplanting depth of 2~3cm and transplanting space of 30cm.

  • PDF

Analysis of Plugging Effect for Open-ended Piles Based on Field Tests (현장시험을 통한 개단말뚝의 폐색효과에 대한 연구)

  • Ko, Jun-Young;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.12
    • /
    • pp.51-61
    • /
    • 2014
  • This paper presents an experimental study of the plugging effect on the capacity of open-ended piles installed in sandy soil. Full-scale tests, including dynamic and static axial-compression load tests, were carried out on three instrumented piles with different diameters (508.0, 711.2 and 914.4 mm). To measure the outer and inner shaft resistances acting on the piles, a double-walled system was utilized with instrumented strain gauges on the outside and inside walls of the pile. The results of field tests show that the inner shaft resistance was mostly mobilized at the location between the pile tip and 18-34% of the total plug length. It was found that the soil plugging in the lower portion has influence on the inner shaft resistance. In addition, it can be also demonstrated that the ratio of inner shaft resistance plus annulus load resistance to total resistance decreased with increasing pile diameters. The results of these tests show that the relationship between the degree of plugging and pile diameter is clearly established. Direct observations of the soil plugs were made and used to quantify both the plug length ratio (PLR) and the incremental filling ratio (IFR). Based on this result, it was found that the N value of the standard penetration test (SPT) is highly correlated with the IFR.

Effect of Mechanical Stress on Postharvest Quality of Baby Leaf Vegetables (재배조건에 따른 어린잎 채소 '다채'의 수확 후 품질변화)

  • Lee, Hye-Eun;Lee, Jung-Soo;Choi, Ji-Weon;Pae, Do-Ham;Do, Kyung-Ran
    • Food Science and Preservation
    • /
    • v.16 no.5
    • /
    • pp.699-704
    • /
    • 2009
  • Commercially produced 'baby leaves' of Brassica campestris var. narinosa (Chinese cabbage) were used in the present study. Baby leaf vegetables were sown on 128 cell plug trays and harvested 30 days after sowing. For mechanical stress experiments, seedlings were thinned to three per cell, selected for uniformity, and watered at the base. Trays were treated with mechanical stress by stroking back and forth 50 times, using a sheet of A4 paper folded to double thickness. Plants were treated between 12:00 and 14:00 daily for 15-20 days. Harvested baby leaf vegetables were packed in MAP salad bags made of P-plus film, $50{\mu}m$ polypropylene (PP) film, and polyethylene terephthalate (PET) boxes. Fresh weight was well-maintained under P-plus and PP film on storage at $8^{\circ}C$. However, loss of fresh weight occurred quickly in PET boxes, and vegetable quality deteriorated rapidly. Stressed leaves were smaller but thicker, with an increased dry weight ratio. We thus suggest that P-plus or PP film is most appropriate packing for marketing of baby leaf vegetables, which should be stored at $8^{\circ}C$. Our data on baby leaf vegetables also make a significant new contribution in that we demonstrate a positive effect of stress touching on baby leaf processability.

Improvement of Straw Loading Method on Survival of Mouse IVF/IVC Blastocysts Cryopreserved by Vitrification (체외수정과 체외배양에서 생산된 생쥐 배반포기배의 초자화 동결에 있어서 Straw Loading 방법의 개선)

  • 김선의;엄상준;김은영;윤산현;박세필;임진호
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • This study was carried out to investigate the effect of straw loading method and thawing protocol on the in vitro development of in vitro produced mouse blastocysts cryopreserved by vitrification. Three loading types of straw I, Il and III on loading and sealing method were made for vitrification. The ability of the solution on straw loading methods to remain vitreous during warming was tested by exposed in air for 1 to 10 s sec. and then plunged the vitrified straws into water bath at 25°C. Embryos to be vitrified were equilibrated to the 20% EG for 5min. and exposed in EFS 40 for 1min. The plug ends of Straw I and Straw II were sealed with straw powder and Straw III was treated straw powder, followed by heat sealing and then plunged into LN$_2$. The results obtained in these experiments were summarized as follows; 1) Straw I embryo column mostly changed from transparent to opaque upon thawing without exposure in air for 3-6 sec. Straw II embryo column was I improved partially but was not remained completely vitreous during warming. However, when Straw lll loading method was used, the embryo column was remained vitreous completely. 2) High survival rates and development rates of each groups (middle blastocysts and hatching blastocysts) of vitrified embryos were obtained by using Straw III loading method than Straw I method (P<0.05). And the range of s standard error was low in Straw lll method. 3) When the embryos vitrified-frozen were placed in air for 3, 5 and l0sec. and then warmed rapidly in water bath at 25$^{\circ}C$, the survival rates after 24h of culture were 72.7-87.1% and the development rates to hatching stage after 48h of culture were 34.0-48.4%. There were no significantly differences according to exposure time in air during warming. In conclusion, the present results showed that highly survival and low standard error of vitrified-frozen mouse bIastocysts were obtained by using straw lll loading, double sealing and appropriate 2 step warming method.

  • PDF