• 제목/요약/키워드: Double Peak Current Limiting

검색결과 5건 처리시간 0.019초

두 개의 자속경로를 갖는 직렬연결형 초전도한류기의 이중 피크전류제한 특성 (Double Peak Current Limiting Properties of Series Connection-Type SFCL with Two Magnetic Paths)

  • 고석철;한태희;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.62-68
    • /
    • 2014
  • We proposed a series connection-type superconducting fault current limiter(SFCL) using E-I core that can prevent the internal magnetic flux generation of cores during normal operation, and prevent the saturation of cores due to a sudden magnetic flux generation at the initial stage of fault occurrence while limiting the peak current. Through a short-circuit simulation experiment, we analyzed the operating status of the two superconducting elements and limiting characteristics according to the size of the fault current peak before and after the failure. Further, the double peak current limiting characteristics according to the winding directions as well as the current and the voltage of each coil were compared and analyzed.

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.

반주기내 한류성능을 위한 진공차단기의 아크소호 (Arc Extinguishing of a Vacuum Interrupter for an HTS First Peak Current Limiter)

  • 김우석;박충렬;현옥배;김혜림;임성우;유승덕;양성은
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.23-26
    • /
    • 2010
  • A double line commutation (DLC) type SFCL with first peak limiting function has been proposed for ideal fault current limiting operation. Very fast switching (commutation) without any arc or high voltage problems for any kind of switching device is needed for the first peak current limiting. We've tried to find suitable conditions for a successful switching of a Vacuum Interrupter (VI) with HTS elements as a Peak Current limiting Resistance (PCR).

삼차권선을 이용한 이중퀜치 자속구속형 초전도한류기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of Double Quench Flux-Lock Type SFCL Using Its Third Winding)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.289-293
    • /
    • 2016
  • The flux-lock type superconducting fault current limiter (SFCL) connects the two parallel windings in parallel with a ferromagnetic core. We suggest that the double quench flux-lock type SFCL should add a third winding. We analyzed characteristics of the fault current and the peak current using the quench of the high-Tc superconducting element. The proposed SFCL's inductances of a primary winding and the third winding were fixed and the amplitude of inductance of the secondary winding was changed. We found that the fault current can be more effectively controlled through the analysis of the equivalent circuit and the short-circuit tests.

전력계통의 지락사고에 대한 매트릭스형 초전도 한류기의 동작특성 (Analysis Operating Characteristics of Matrix-Type Superconducting Fault Current Limiter in Ground Faults of Power Grid)

  • 오금곤;조용선;최효상;오성보;김덕구
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.14-20
    • /
    • 2009
  • 전력 계통 내에서 발생하는 과도한 고장전류의 억제를 위한 가장 이상적인 방안은 초전도 한류기이다. 초전도 한류기의 전력계통 적용을 위해 본 논문에서는 전력계통 내에서 발생하는 1선, 2선, 3선 지락사고를 모의하여 매트릭스형 초전도 한류기의 동작 특성 및 소비전력을 분석하였다. 모든 지락사고에 대해 매트릭스형 초전도 한류기는 사고 초기에는 85[%] 이상, 1주기 이후에는 95[%] 이상 고장전류를 제한시킬 수 있다는 것을 확인하였다. 또한 초전도 소자간의 임계특성의 차이를 줄여줌으로써 소비전력이 균등해진다는 것을 확인하였다.