• Title/Summary/Keyword: Double Operation

Search Result 824, Processing Time 0.029 seconds

Performance of Double Fed Induction Machine at Sub- and Super-Synchronous Speed in Wind Energy Conversion System

  • Eskander, Mona N.;Saleh, Mahmoud A.;El-Hagry, Mohsen M.T.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.575-581
    • /
    • 2009
  • In this paper two modes of operating a wound rotor induction machine as a generator at sub-and super-synchronous speeds in wind energy conversion systems are investigated. In the first mode, known as double fed induction generator (DFIG), the rotor circuit is fed from the ac mains via a controlled rectifier and a forced commutated inverter. Adjusting the applied rotor voltage magnitude and phase leads to machine operation as a generator at sub-synchronous speeds. In the second mode, the machine is operated in a slip recovery scheme where the slip energy is fed back to the ac mains via a rectifier and line commutated inverter. This mode is described as double output induction generator (DOIG) leading to increase the efficiency of the wind-to electrical energy conversion system. Simulated results of both modes are presented. Experimental verification of the simulated results are presented for the DOIG mode of operation, showing larger amount of power captured and better power factor when compared to conventional induction generators.

Efficient Implementation of Single Error Correction and Double Error Detection Code with Check Bit Pre-computation for Memories

  • Cha, Sanguhn;Yoon, Hongil
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.418-425
    • /
    • 2012
  • In this paper, efficient implementation of error correction code (ECC) processing circuits based on single error correction and double error detection (SEC-DED) code with check bit pre-computation is proposed for memories. During the write operation of memory, check bit pre-computation eliminates the overall bits computation required to detect a double error, thereby reducing the complexity of the ECC processing circuits. In order to implement the ECC processing circuits using the check bit pre-computation more efficiently, the proper SEC-DED codes are proposed. The H-matrix of the proposed SEC-DED code is the same as that of the odd-weight-column code during the write operation and is designed by replacing 0's with 1's at the last row of the H-matrix of the odd-weight-column code during the read operation. When compared with a conventional implementation utilizing the odd-weight- column code, the implementation based on the proposed SEC-DED code with check bit pre-computation achieves reductions in the number of gates, latency, and power consumption of the ECC processing circuits by up to 9.3%, 18.4%, and 14.1% for 64 data bits in a word.

A Experimental Study of Cup forming by Stretch-Drawing Process (인장드로잉법에 의한 원통성형에 관한 실험적 연구)

  • 김영수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.123-128
    • /
    • 2000
  • Fundamental and informative data of axi-symmetric stretch-drawing of several sheetmetals with thicknesses of 0.7-1.0mm are presented both for single and double operations. Very small radius is applied to the die profile (or-shoulder) ion all operations. to induce wall-thinning by the effect of bending-under-tension from which the name 'stretch-drawing' comes. It is clearly demonstrated that deeper cups could be formed by single and double stretch-drawings from smaller circular blanks due to such wall-thinning action than in the usual deep-drawing of larger blanks, From this fact it is emphasized that the deep-drawability of a sheet metal is not evaluated simply by the conventional L.D.R (limiting drawing ratio) but the depth of the drawn cup should also be taken into account./ Many experimental data about various metals and thicknesses given in this paper offer a valuable information in this process for more general use which recommends to replace the conventional deep-drawing process by the stretch-drawing process both for single and double operations. In the single stretch-drawing it is also confirmed that a deeper cup can be produced by raising the blank-holding force at later stage of operation.

  • PDF

Esophageal Atresia with Double Tracheoesophageal Fistula - A Case Report - (근,원위부 기관 식도루를 가진 식도 폐쇄증 - 1예 보고 -)

  • Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.14 no.1
    • /
    • pp.88-93
    • /
    • 2008
  • Esophageal atresia with double tracheoesophageal fistula is a very rare anomaly and is difficulty to diagnose preoperatively. We treated a full term baby with esophageal atresia with double tracheoesophageal fistula. At the first operation, only the distal tracheoesophageal fistula was identified and ligated. When the upper esophageal pouch was opened, intermittent air leakages in sequence with positive bagging were noticed. However, intraoperative bronchoscopy did not identify a fistula in the proximal pouch, and the operation was completed with end to end anastomosis of the esophagus. On the $7^{th}$ postoperative day, esophagography showed another tracheoesophageal fistula proximal to the esophageal anastomosis. A wire was placed in the fistula preoperatively under bronchoscopy. At the 2nd operation through the same thoracotomy incision the proximal fistula was identified and ligated. On the $12^{th}$ postoperative day, esophagography showed neither stricture nor leakage.

  • PDF

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types (이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석)

  • Shin-Won Lee;Tae-Hee Han;Sung-Hun Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

Cardiac Valve Replacement: A Report of 16 Cases (심장판막 이식에 관한 연구)

  • 김주현;이영균
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.89-100
    • /
    • 1975
  • Sixteen cases of cardiac valve replacements have been done in this department since 1970. Twelve cases of mitral valve replacement were done with Beall valve, 2 cases of aortic valve replacement with Starr-Edwards and Magoven valve and 2 cases of double valve replacement using Beall valve for mitral and Magovern valve for aortic. Three patients [18.8%] died during operation. Two cases [12.5%] of hospital mortality occurred because of congestive heart failure and asphyxia due to tracheomalacia 3 months after operation. Follow-up studies from two to 27 months showed excellent results except three cases of late mortality [18.8 %]. Thromboembolism occurred in two double valve replacement patients[12.5%]who were fatal.

  • PDF

Double Encryption of Image Based on Scramble Operation and Phase-Shifting Digital Holography (스크램블 연산 및 위상 천이 디지털 홀로그래피 기반 영상 이중 암호화)

  • Kim, Cheol-Su
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.4
    • /
    • pp.13-22
    • /
    • 2018
  • In this paper, double encryption technology of image based on scramble operation and phase-shifting digital holography is proposed. For the purpose, we perform first encryption digitally using scramble operation for the to be encrypted image, and perform phase modulation to the first encrypted image. Finally, we get the secondary encryption information through the interference between the phase-shifted reference wave and phase modulated image. The decryption process proceeds in the reverse order of the encryption process. The original image is reconstructed by digitally decoding the two encrypted images through a phase shift digital holography technique that appropriately performs arithmetic processing, phase-demodulating and then using the encryption key information used in the scramble operation. The proposed cryptosystem can recover the original image only if both the key information used in the scramble operation, the distance information used in the phase shift digital holography technique, and the wavelength of the light source are known accurately.

Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils (3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

NLMS Adaptive Filter Based Acoustic Echo Canceller (NLMS 적응 필터 기반의 음향 반향 제거기)

  • Hwang, Sung-Sue;Yun, Sang-Suk;Kim, Suk-Chan;Lee, Chae-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4C
    • /
    • pp.343-349
    • /
    • 2010
  • In this paper, we study real time AEC (acoustic echo canceller) based on NLMS adaptive filter. Proposed method improves conversation quality by enhancing the performance of AEC during double talk section and reduces the power consumption by controling the adaption operation of NLMS adaptive filter. Proposed method examines the convergence of the NLMS adaptive filter, stores the estimated echo path and chooses operation of NLMS adaptive filter. Furthermore if double talk is detected, the proposed AEC utilizes the stored echo path optionally considering missed double talk time. When the proposed AEC is used, the performance of the AEC is enhanced although the simple double talk detector is used and the power consumption of the AEC is reduced.

Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench (이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석)

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.