Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교 (Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters)

  • 이정우;홍세미;최경식;정진범;최보영;장홍석;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2005
  • 기능강화동적쐐기는 쐐기 형태의 선량 분포를 만드는 방법과 선량 특성적인 면에서 금속쐐기와 상당한 차이를 가지고 있다. 기능강화동적쐐기의 임상적용을 위해서는 금속쐐기와 다른 선량특성을 분석하고 이에 따른 적절한 커미셔닝이 필수적이다. 본 연구의 목적은 기본 선량계측인자에 기초한 기능강화동적래기와 금속쐐기의 선량특성을 분석하는 데 있다 선량 계측학적 특성을 나타내는 심부선량분포, 조사면 주변 선량, 표면선량, 실효 쐐기인자, 쐐기의 선량측면도를 측정, 분석하였다. 또한 열린 조사면과 금속쐐기와의 비교측정을 통해 기능강화동적쐐기가 가지고 있는 고유한 특성을 분석하였다. 기능강화동적쐐기의 선량측면도 측정은 Chamber Array 24 (CP24)를 이용하였으며, Golden Segmented Treatment Table (Golden-577)로 구현한 치료 계획 장치의 계산 값과 비교하였다. 또한 실호쐐기인자 측정은 각각의 X, Y 콜리메이터에 따른 특성을 분석하였다. 심부 선량 백분율측정에서 열린 조사면과 기능강화쐐기의 비교결과, $0.2\~0.5\%$ 이내로 일치하였고, 금속 쐐기인 경우 약 $2\%$의 비교적 큰 차이를 보였다. 조사면 주변선량측정에서는 금속쐐기가 약 $1\%$ 높았다. 표면선량 측정 결과, 금속쐐기가 약 $10\%$ 낮게 평가되었다 기능강화쐐기의 실효쐐기인자는 Y jaw가 커짐에 따라 연속적으로 감소됨을 알 수 있었다. X jaw에 따른 쐐기인자 의존도 측정에서는 X jaw에 따른 의존도는 거의 없는 것으로 평가되었다. 또한 비대칭 조사면의 쐐기 인자측정에서는 비대칭에 상관없이 Y jaw의 크기만 같으면 실효쐐기인자가 같았다. 선량측면도 측정에서는 CA24를 이용해 얻은 실측값과 Golden STT로 Cadplan에서 구현한 계산 값이 $1\%$이내로 일치하였다. 본 연구를 통해 기능강화동적쐐기가 가지고 있는 특성을 분석하였으며, 금속쐐기를 대체할 수 있는 유용한 도구임을 알 수 있었다.

  • PDF

Vacuum Cushion 사용시 표면선량과 투과율 평가 (Surface Dose and Transmission Factor for Vacuum Cushion)

  • 김미화;이병용;전미선
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.74-78
    • /
    • 2002
  • 환자 치료시 환자의 위치고정과 매번 치료에서 환자 치료 자세의 재현을 위해 사용하는 고정물(immobilizer)중 Vacuum cushion을 사용시 Vacuum cushion으로 인해 예상되는 표면선량 또는, 투과량의 변화들을 측정하여 Vacuum cushion의 특성을 평가하였다. 광자선 에너지 4 MV (Varian 4/100, 미국), 6MV, 15 MV (Varian CL2100C/D, 미국)에 대해서 조사면의 크기를 5$\times$5, 10$\times$10, 20$\times$20, 30$\times$30, 40$\times$40 $\textrm{cm}^2$로, Vacuum cushion의 두께는 12, 32, 48 mm, 그리고 스티로폼이 없이 진공 봉지만 있는 경우로 변화해가며 Vacuum cushion에 대해 팬톰 표면에서 d$_{max}$까지의 선량을 측정하였다. 그 결과 vacuum cushion 두께에 대한 투과율은 0.9953-1.0043의 분포로 거의 차이가 없었다. 그리고 vacuum cushion의 두께가 두꺼워질수록, 환자가 받는 표면 선량은 증가하였다. 에너지, 조사면 크기에 대해 Vacuum cushion의 두께에 따라 표면 선량의 변화가 있었으나 6 MV와 15 MV에 대해 알려진 aquaplast의 데이타와 가장 두꺼운(48mm) vacuum cushion의 표면선량 증가율을 비교시 aquaplast보다 대략 16, 12% 낮아 임상에 적용하는데 무리가 있을 만큼 심각한 문제가 아니었다.

  • PDF

물 흡수선량 표준에 기반한 선량교정 프로그램 개발 (Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.175-183
    • /
    • 2003
  • 최근 선량측정의 정확성을 향상시키기 위하여 기존의 공기커마 교정인수에 기반한 표준측정법에서 물 흡수선량 교정인수에 기반한 표준측정법으로 변환하고 있는 추세이다. 본 연구에서는 미국의학물리학회의 AAPM TG-51과 국제원자력기구의 IAEA TRS-398 표준측정법에 대한 선량교정 프로그램을 개발하였다. 이 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 C++언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스화함으로써 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

Therapeutic Effect of Gamma Knife Radiosurgery for Multiple Brain Metastases

  • Lee, Chul-Kyu;Lee, Sang-Ryul;Cho, Jin-Mo;Yang, Kyung-Ah;Kim, Se-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.179-184
    • /
    • 2011
  • Objective : The aim of this study is to evaluate the therapeutic effects of gamma knife radiosurgery (GKRS) in patients with multiple brain metastases and to investigate prognostic factors related to treatment outcome. Methods : We retrospectively reviewed clinico-radiological and dosimetric data of 36 patients with 4-14 brain metastases who underwent GKRS for 264 lesions between August 2008 and April 2011. The most common primary tumor site was the lung (n=22), followed by breast (n=7). At GKRS, the median Karnofsky performance scale score was 90 and the mean tumor volume was 1.2 cc (0.002-12.6). The mean prescription dose of 17.8 Gy was delivered to the mean 61.1% isodose line. Among 264 metastases, 175 lesions were assessed for treatment response by at least one imaging follow-up. Results : The overall median survival after GKRS was $9.1{\pm}1.7$ months. Among various factors, primary tumor control was a significant prognostic factor ($11.1{\pm}$1.3 months vs. $3.3{\pm}2.4$ months, p=0.031). The calculated local tumor control rate at 6 and 9 months after GKRS were 87.9% and 84.2%, respectively. Paddick's conformity index (>0.75) was significantly related to local tumor control. The actuarial peritumoral edema reduction rate was 22.4% at 6 months. Conclusion : According to our results, GKRS can provide beneficial effect for the patients with multiple (4 or more) brain metastases, when systemic cancer is controlled. And, careful dosimetry is essential for local tumor control. Therefore, GKRS can be considered as one of the treatment modalities for multiple brain metastase.

토모테라피에서 선량품질보증 분석을 위한 통계적공정관리의 타당성 (Feasibility on Statistical Process Control Analysis of Delivery Quality Assurance in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.491-502
    • /
    • 2022
  • The purpose of this study was to retrospectively investigate the upper and lower control limits of treatment planning parameters using EBT film based delivery quality assurance (DQA) results and to analyze the results of statistical process control (SPC) in helical tomotherapy (HT). A total of 152 patients who passed or failed DQA results were retrospectively included in this study. Prostate (n = 66), rectal (n = 51), and large-field cancer patients, including lymph nodes (n = 35), were randomly selected. The absolute point dose difference (DD) and global gamma passing rate (GPR) were analyzed for all patients. Control charts were used to evaluate the upper and lower control limits (UCL and LCL) for all the assessed treatment planning parameters. Treatment planning parameters such as gantry period, leaf open time (LOT), pitch, field width, actual and planning modulation factor, treatment time, couch speed, and couch travel were analyzed to provide the optimal range using the DQA results. The classification and regression tree (CART) was used to predict the relative importance of variables in the DQA results from various treatment planning parameters. We confirmed that the proportion of patients with an LOT below 100 ms in the failure group was relatively higher than that in the passing group. SPC can detect QA failure prior to over dosimetric QA tolerance levels. The acceptable tolerance range of each planning parameter may assist in the prediction of DQA failures using the SPC tool in the future.

토모테라피 Edge 모드를 이용한 임상적 유용성 고찰 (Dosimetric and clinical review on the application of TOMO_edge mode)

  • 김이지
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.177-182
    • /
    • 2014
  • 목 적 : 토모테라피(Tomotherapy)의 두 가지 빔 모드(fixed jaw, dynamic jaw)에 따른 선량 분포 특성과 치료 시간의 차이를 분석하여 dynamic jaw(DJ)를 이용한 Tomo_edge 모드의 임상적 유용성을 고찰하고자 하였다. 대상 및 방법 : 토모테라피를 이용하여 치료받은 환자 7명을 대상으로 임상에서 보편적으로 사용되는 fixed jaw(FJ)를 이용하여 치료 계획을 수립하였다. 각각의 환자에서 모두 동일한 선량계획조건을 부여하였고, 토모테라피의 치료계획 인자인 Modulation Factor(MF), Pitch를 동일하게 유지한 상태에서 1) 동일한 조사면을 적용하고 FJ 와 DJ를 적용한 치료 계획을 비교하였다. 2) FJ를 적용한 치료 계획과 한 단계 큰 조사면과 DJ를 적용한 치료 계획을 비교하였다. 각 실험의 결과는 선량분포의 특성을 확인하기 위하여 종양체적 내 최소값(Dmin)과 선량 조형지수(CI=$V_{95%}$/TV)를 비교하고 표적을 포함한 조사영역 내 체적의 누적선량을 분석하였다. 또한, 임상적 유용성을 확인하기 위하여 빔 조사시간과 MU의 증감을 비교 분석하였다. 결 과 : 동일한 조사면을 적용하고 FJ와 DJ를 적용한 경우, $V_{75%}$은 1.04%, $V_{50%}$은 4.75% 감소하였고, $V_{25%}$은 7.6%, $V_{10%}$은 11.91% 감소하였다. FJ를 적용한 치료계획보다 한 단계 큰 조사면과 DJ를 적용한 경우에 Dmin은 0.72%, CI는 1.25% 줄어들었고, 동일 조사면을 적용한 경우와 마찬가지로 $V_{x%}$는 저선량 영역으로 갈수록 크게 감소하여 $V_{10%}$이 6.13%의 감소 값을 나타냈다. 빔 조사시간과 누적 MU는 동일 조사면 적용 시 각각 3.66%와 3.77%의 값으로 증가하였으나, 한 단계 큰 조사면을 적용한 경우, 빔 조사시간이 31.55%로 누적 MU는 32.28%으로 크게 감소하였음을 보여준다. 결 론 : 동일한 조사면을 사용하면서 DJ를 사용하는 경우, 표적의 선량분포를 거의 변화시키지 않으면서 환자의 용적선량을 효과적으로 감소시킬 수 있었다. 보다 큰 조사면을 사용하는 것과 동시에 DJ를 사용하는 경우는 일부 선량조형성의 저하를 나타내었으나 환자의 용적선량이 감소하고 치료 시간을 감소시킴으로써 Tomo-edge 모드는 임상적으로 유용한 것으로 사료된다.

CLINAC 1800 선형가속기의 15 MV X-선의 특성 (Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator)

  • 김계준;이종영;박경란
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.131-141
    • /
    • 1991
  • 국내에서 처음으로 사용되는 CLINAC 1800에서 발생된 15MV X-선의 특성을 구하기 위하여 3 Dimensional water Phantom Dosimetry system)를 이용하여 방사선 치료에 근간이 되는 심부선량 백분율(POD), 최대 조직 비율(TMR), 편평도(beam profile), 대칭도, Wedge인자 등을 측정하였고 선량계산을 위하여 출력 인자들을 구하였다. 1. 선축상 최대치 지점(Dmax)은 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $3.0\pm0.1$ cm이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $3.1\pm0.1\;cm,2.2\pm0.1$ cm으로 조사면이 넓어지면서 측정치가 표면에 가까워지는 결과를 보였다. 2. 조직표면 선량(Surface Dose)는 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $15.5\%$이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $9.8\%\;,51.2\%$로 조사면이 넓어지면서 표면 선량은 증가하는 결과를 보였다. 3. 심부선량 백분율(PDO)은 SSD 100cm에서 측정하였고 조사면이 $10\times10cm^2$이고 10cm depth에서 $76.8\%$이였고 $80\%,\;50\%$ 선량의 깊이는 각각 $9.1\pm0.1\;cm,19.9\pm0.2\;cm$으로 측정되었다. 4. 최대조직비율(TMR)은 심부선량 백분율(PDD)로부터 계산하였고 측정값과의 차이는 $10\times10cm^2$ 조사면에서 평균 $1\;%$ 이내의 오차를 보였다. 5. 대칭도(symmetry)와 편평도(flatness)는 조사면 $10\times10cm^2$일때 각각 $0.73\%,\;2.72\%$이였다. 6. 출력인자(output factor)는 $10\times10cm^2$ 기준 조사면에서 흡수선량을 1로 하였을때 $4\times4cm^2,\;35\times35cm^2$ 조사면에서는 각각 0.927, 1.087로 측정되었는데 조사면이 증가할수록 흡수량이 증가하는 결과를 보였다. 7. Wedge factor는 $15^{\circ}\;30^{\circ}\;45^{\circ}\;60^{\circ}$를 10cm깊이에서 측정하였는데 0.825, 0.099, 0.560, 0.457로 각각 측정되었고 아크릴 0.4 mm Tray의 투과율은 0.976이였다. 8. 15 MV X-선에 의한 납벽층의 반가층 두께는 13 mm였고 Cerrobend의 반가층은 15.5 mm으로 측정되었다.

  • PDF

MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교 (Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter)

  • 정진범;이정우;김연래;이두현;최경식;김재성;김인아;홍세미;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제18권1호
    • /
    • pp.48-54
    • /
    • 2007
  • 본 연구는 MOSFET (Metal Oxide Semiconductors Fleid Effect Transistors) 선량계의 교정과 특성분석을 위해서, 자체 팬톰을 개발하고 이 팬톰을 적용하여 표준감도와 고감도 두 종류의 MOSFET선량계의 특성을 비교 평가하는 것이다. 본 연구에서 개발한 팬톰은 직경 10cm의 반구형 모양인 팬톰과 1cm 두께 $30{\times}30cm^2$의 평판형의 팬톰으로 아크릴로 제작되었다. 평판형 팬톰은 MOSFET 선량계의 교정과 선량재현성, 선량직선성, 선량률 의존성을 측정하는데 사용하였으며 반구형 팬톰은 빔 입사각도 및 선량계 방향에 대한 MOSFET 선량계 특성을 분석하기 위해서 사용하였다. 모든 측정과정은 선형가속기(CL21EX, Varian, USA)의 6 MV 광자선, SSD 100cm, 조사면 $10{\times}10 cm^2$에서 수행하였다 선량계 교정과 선량재현성 평가에 사용된 5개의 표준감도와 고감도 MOSFET 선량계에 각각 200 cGy로 5번 반복 조사하여 $1.09{\pm}0.01{\sim}1.12{\pm}0.02,\;2.81{\pm}0.03{\sim}2.85{\pm}0.04mV/cGy$. 범위의 평균 교정계수가 결정되었고 선론쌔현성은 두 선량계 모두 2%이내로 거의 동일하였다. $5{\sim}600\;cGy$ 범위에서의 선량직선성은 두 MOSFET 선량계 모두 결정계수 $R^2=0.997$, 0.999인 좋은 선량직선성을 나타내었다. 200 cGy로 $100{\sim}600\;MU/min$ 범위의 선량률 의존성도 1%이내로 두 선량계가 동일하게 나타났다. 그러나 빔 입사각도와 선량계 방향의 의존성 평가에서, 표준감도와 고감도 MOSFET선량계는 평균적으로 빔 입사각도에 대해 13%, 10%의 변동폭과 ${\pm}4.4%$${\pm}2.1%$의 표준편차가 있었으며, 선량계 방향에 대해 5%, 2%의 변동폭, ${\pm}2.1%$${\pm}1.5%$의 표준편차로 두 선량계 간 현저한 차이를 나타났다 그러므로 여러 방향의 치료빔을 사용하는 방사선 치료의 선량검증을 위해서는 빔 입사각도와 선량계 방향의 의존성이 적은 고감도 MOSFET 선량계를 사용하는 것이 표준감도 WOSFET 선량계를 사용하는 것보다는 더 정확한 선량검증을 수행할 수 있을 것으로 사료된다.

  • PDF

방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성 (Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy)

  • 추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.77-88
    • /
    • 1998
  • 쐐기형 선량분포는 임상에 많이 응용하고 있으며 고정쐐기여과판은 선질의 강화와 조사면 주위 의 산란선 증가, 등선량 각도의 불일치, 여과판의 장착 및 취급이 부정확하고 어려우며 입체조형 방사선 치료시 많은 조사면을 입체방향으로 중첩시킴으로서 발생되는 선량의 불균질을 방지하고 동적입체방사선조형치료(dynamic 3D conformal radiotherapy) 및 선량강도조절치료(intensity modulation radiotherapy)를 가능케 하는 동적쐐기여과판을 고안 제작한다. 동적쐐기여과판은 콜리메이터를 움직이면서 선량율을 변화시켜서 최적한 쐐기각의 등량곡선을 얻을 수 있도록 미분치료표(segmented treatment tables: STT) 유도하며 표준형의 STT를 컴퓨터에 입력시킨다. STT에 의하여 생성되는 동적쐐기여과판의 특성과 조직내 선량분포를 쐐기각, 조사변의 크기, 조사선량율둥 여러 조건하에서 측정 분석함으로서 방사선 감수성이 높은 장기 내의 종양과 저항성 이 강한 악성종양치료에 도움을 주며 전반적인 방사선치료 성과를 향상시키고자 한다. 연세암센터에서 가동되는 선형가속기 (Varian Clinac-2100C/D)를 이용하여 6MV 와 10MV 광자선과 쐐기각이 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$이고 정사각형 조사면의 한변이 4cm 부터 20cm 범위를 0.5cm 간격으로 콜리메이터를 움직이면서 선량 변동량을 표시하는 미분치료표 (STT)를 작성하였다. 쐐기투과선량인자 (wedge transmission factor) 는 표준 물팬텀내에 표준전리함을 장치하고 열린조사면과 미분치료표에 의한 쐐기조사면의 선량비료서 결정하였다. 쐐기여과판에 의한 조직내선량분포와 등량곡선 및 프로파일은 필름으로 측정하고 영상선량측정기로 작성하였다. 수식으로 유도한 미분치료표(segmented treatment tables: STT) 은 쐐기여과판의 쐐기각과 일치하였으며 쐐기투과선량인자는 쐬기각이 클수록 감소하였으며 조사변이 클수록 적어졌고 조사면 크기와의 관계는 비선형적이었다. 동적쐐기여과판에 의한 등량곡선의 쐐기 기울기는 고형여과판보다 더욱 일치된 경사각을 유지하였다. 심부선량백율은 열린조사면에 의한 것과 거의 비슷하였으며 고형쐐기여과판의 심부율보다 약간 줄어들었다. 동적쐐기여과판은 고형쐐기여과판보다 사용상, 선량측정 및 선량분포에 서 장점이 많으며 피부와 여과판사이의 길이가 길어서 침대에 부딪치는 일이 없고 피부의 산란선 오염이 감소되어 치료효과를 상승시킬 수 있다. 동적쐐기조사방법을 개발함으로서 지금까지 방사선 후유증과 종양의 불균일한 선량배열로 치료의 어려움이 있었던 분야를 개척할 수 있으며 동적입체 방사선조형치료 (dynamic 3D conformal radiotherapy) 및 선량강도조정치료 (intensity modulation radiotherapy)를 가능하게 함으로서 방사선치료성과를 향상시킬 수 있다.

  • PDF