• Title/Summary/Keyword: Dose-area product

Search Result 94, Processing Time 0.021 seconds

Distribution of Mast cells and Nerves in the Developing Postnatal Submandibular and Sublingual Glands of Rats (생후 발생중인 흰쥐의 턱밑샘 및 혀밑샘에서의 비만세포와 신경의 분포양상)

  • Kim, Jae-Gon;An, Soo-Hyeon;Lee, Young-Su;Baik, Byeong-Ju;Cho, Eui-Sic
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.350-364
    • /
    • 1999
  • The distribution of mast cells and nerves were investigated in the submandibular and sublingual glands of postnatal rats, using morphometric, histochemical and immunohistochemical techniques. Mast cells were observed in the submandibular and sublingual glands of postnatal development. Number of mast cells gradually increased in both glands following development. At birth, mast cells were relatively fewer in submandibular gland than those in sublingual gland, and they were mainly distributed in parenchymal tissues. At $2{\sim}4$ weeks, most of the mast cells were observed in the connective tissues, surrounding neurovascular elements, but some mast cells were closely related with the acini of submandibular gland. PGP 9.5 immunoreactive nerve fibers were found in the submandibular and sublingual glands of all developmental age. The nerve fibers were showed in varicose shape, and mainly located in adjacent area of ducts and vascular components of both glands. The number of nerve fibers were increased rapidly until 8 weeks, but they were not increased any more until 24 weeks. Therefore, it is suggested that mast cells and nerve fibers related with each other, and that their interactions may play roles not only in maturation of secretory units but also growth and differentiation of the tubular structures of the rat submandibular and sublingual glands during postnatal development.

  • PDF

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Optimization of Tube Voltage according to Patient's Body Type during Limb examination in Digital X-ray Equipment (디지털 엑스선 장비의 사지 검사 시 환자 체형에 따른 관전압 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.379-385
    • /
    • 2017
  • This study identifies the optimal tube voltages depending on the changes in the patient's body type for limb tests using a digital radiography (DR) system. For the upper-limp test, the dose area product (DAP) was fixed at $5.06dGy{\ast} cm^2$, and for the lower-limb test, the DAP was fixed at $5.04dGy{\ast} cm^2$. Afterwards, the tube voltage was changed to four different stages and the images were taken three times at each stage. The thickness of the limbs was increased by 10 mm to 30 mm to change in the patient's body type. For a quantitative evaluation, Image J was used to calculate the contrast to noise ratio (CNR) and signal to noise ratio (SNR) among the four groups, according to the tube voltage. For statistical testing, the statistically significant differences were analyzed through the Kruskal-Wallis test at a 95% confidence level. For the qualitative analysis of the images, the pre-determined items were evaluated based on a 5-point Likert scale. In both upper-limb and lower-limb tests, the more the tube voltage increased, the more the CNR and SNR of the images decreased. The test on the changes depending on the patient's body shape showed that the more the thickness increased, the more the CNR and SNR decreased. In the qualitative evaluation on the upper limbs, the more the tube voltage increased, the more score increased to 4.6 at the maximum of 55kV and 3.6 at 40kV, respectively. The mean score for the lower limbs was 4.4, regardless of the tube voltage. The more either the upper or lower limbs got thicker, the more the score generally decreased. The score of the upper limps sharply dropped at 40kV, whereas that of the lower limps sharply dropped at 50kV. For patients with a standard thickness, the optimized images can be obtained when taken at 45kV for the upper limbs, and at 50kV for the lower limbs. However, when the thickness of the patient's limbs increases, it is best to set the tube voltage at 50 kV for the upper limbs and at 55 kV for the lower limbs.