• Title/Summary/Keyword: Dose planning

Search Result 718, Processing Time 0.032 seconds

PET/CT planning during chemoradiotherapy for esophageal cancer

  • Seol, Ki Ho;Lee, Jeong Eun
    • Radiation Oncology Journal
    • /
    • v.32 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: To evaluate the usefulness of positron emission tomography/computed tomography (PET/CT) for field modification during radiotherapy in esophageal cancer. Materials and Methods: We conducted a retrospective study on 33 patients that underwent chemoradiotherapy (CRT). Pathologic findings were squamous cell carcinoma in 32 patients and adenocarcinoma in 1 patient. All patients underwent PET/CT scans before and during CRT (after receiving 40 Gy and before a 20 Gy boost dose). Response evaluation was determined by PET/CT using metabolic tumor volume (MTV), total glycolytic activity (TGA), MTV ratio (rMTV) and TGA ratio (rTGA), or determined by CT. rMTV and rTGA were reduction ratio of MTV and TGA between before and during CRT, respectively. Results: Significant decreases in MTV ($MTV_{2.5}$: mean 70.09%, p < 0.001) and TGA ($TGAV_{2.5}$: mean 79.08%, p < 0.001) were found between before and during CRT. Median $rMTV_{2.5}$ was 0.299 (range, 0 to 0.98) and median $rTGAV_{2.5}$ was 0.209 (range, 0 to 0.92). During CRT, PET/CT detected newly developed distant metastasis in 1 patient, and this resulted in a treatment strategy change. At a median 4 months (range, 0 to 12 months) after completion of CRT, 8 patients (24.2%) achieved clinically complete response, 11 (33.3%) partial response, 5 (15.2%) stable disease, and 9 (27.3%) disease progression. $SUV_{max}$ (p = 0.029), $rMTV_{50%}$ (p = 0.016), $rMTV_{75%}$ (p = 0.023) on intra-treatment PET were found to correlate with complete clinical response. Conclusion: PET/CT during CRT can provide additional information useful for radiotherapy planning and offer the potential for tumor response evaluation during CRT. $rMTV_{50%}$ during CRT was found to be a useful predictor of clinical response.

Impact of Smaller Gantry Arc Increments on Volumetric Modulated Arc Radiation Therapy in the Monaco Treatment Planning System

  • Seonghee Kang;Hyejo Ryu;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Progress in Medical Physics
    • /
    • v.35 no.3
    • /
    • pp.65-72
    • /
    • 2024
  • Purpose: This study aims to evaluate the impact of smaller gantry arc increment (GAI) values on the plan quality and deliverability of volumetric modulated arc therapy (VMAT) for head and neck (HN) and prostate cancer cases using the Monaco treatment planning system. The study investigates whether a smaller GAI can enhance organ at risk (OAR) sparing without compromising target coverage or significantly increasing plan complexity. Methods: VMAT plans were created for 20 patients (10 HN and 10 prostate cancer) using GAI values of 15° and 30°. Dose-volumetric parameters, such as conformity number, homogeneity and gradient indices, were assessed alongside plan complexity metrics like the modulation complexity score for VMAT (MCSv) and monitor unit (MU). Statistical significance was determined using the Wilcoxon signed-rank test. Results: For HN cases, a 15° increment significantly reduced the D0.03cc for the spinal cord and the Dmean for both parotid glands compared to a 30° increment, improving OAR sparing. However, no significant differences were observed in the OAR doses for prostate cases. The 15° increment resulted in higher plan complexity, reflected by a lower MCSv, but the MU difference was not significant. Conclusions: Smaller GAI values, such as 15°, can significantly reduce OAR doses in HN VMAT plans, offering potential clinical benefits despite increased plan complexity. However, no substantial advantages were observed in prostate cases. These findings suggest that smaller GAI values may be particularly beneficial for cases requiring high modulation.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters (선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교)

  • Lee Jeong-Woo;Hong Semie;Choi Kyoung-Sik;Chung Jin-Beom;Choe Bo-Young;Jang Hong Seok;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2005
  • For clinical implementation of Enhanced Dynamic Wedge (EDW), it is necessary to adequately analyze and commission its dosimetric properties in comparison to common physical metal wedge (MTW). This study was implemented with the essential measurements of parameters for clinical application, such as percentage depth dose, peripheral dose, surface dose, effective wedge factor, and wedge profile. In addition, through the comparison study of EDW with open and MTW, the analysis was performed to characterize the EDW. We also compared EDW dose profiles of measured values using chamber array 24 (CA24) with calculated values using radiation treatment planning system. PDDs of EDW showed good agreements between $0.2\~0.5\%$ of open beam, but $2\%$ differences with MTW. In the result of the measurements of peripheral dose, it was shown that MTW was about $1\%$ higher than open field and EDW. The surface doses of $60^{\circ}$ MTW showed 10% lower than the others. We found that effective wedge factor of EDW had linear relationships according to Y jaw sizes and was independent of X jaw sizes and was independent of X jaw sizes and asymmetric Y jaw opening. In comparison with measured values and calculate values from Golden-STT based radiation treatment planning system (RTP system), it showed very good agreement within difference of $1\%$. It could be concluded that EDW is a very reliable and useful tool as a beam modification substitute for conventional MTW.

  • PDF

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Studies on changes in bulks of body per dose and in the positioning of duodenum by respiration when treating pancreatic cancer patients with radiation therapy (췌장암 환자의 방사선 치료 시 호흡에 따른 십이지장의 위치 변화 및 선량 당 체적 변화에 대한 연구)

  • Jang, Hyeong-Jun;Chun, Geum-Seong;Park, Yeong-Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • Purpose : In the case of treating pancreatic cancer, the importance is put on the spread of dose. Changes take place in duodenum in accordance with respiration. Thus, in this paper, I am going to trace the positioning of duodenum and the changes in bulks of body per dose by scanning the patients' Kilovoltage Cone-Beam CT using the hospital equipped CT-on rail System. Materials and Methods : Seeing three patients, I have acquired KVCBCT by using CT-on rail System and spotted the change in positioning at duodenum after comparing with the preliminary image of treatment plan by using SYNGO Software. Then, I followed the change in the bulk of duodenum and analyzed the changes in bulks of body on the same dose by transmitting the acquired KVCBCT into Pinnacle, a treatment plan system. Results : The changes in the positioning shall be as set forth like this: 1.2cm, 1.0cm in Left-Right Direction, 0cm, 0.8cm in Craniocaudal Direction, 0.1cm, and 1.0cm in Anterior-Posterior Direction. Patient number one showed that his bulks in body had increased by maximum 460%, minimum 120%, the bulks in patient number two had increased bymaximum 490%, minimum 160%, and the bulks of patient number three had increased by maximum 150%. But Minimum volume decreased 30%. Patient number one showed only a little bit of change at first when compared with the preliminary treatment plan. However, the dose increased the bulks in the patient's body: $V_{10}$ 118%, $V_{20}$ 117%, $V_{30}$ 400%, and $V_{40}$ 480% Conclusion : In treating patients with radiation therapy using 3D-CRT, the dose amount penetrated into duodenum needs to be minimized by planning appropriate treatment beforehand. In order to establish an appropriate treatment plan it is required to comprehend the changes at positioning of the duodenum by respiration and predict the changes in the bulks of duodenum by setting precise Planning Target Volume.

Comparison of Treatment Plans with Multileaf Collimators of different Leaf Width (Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교)

  • Kim Joo Young;Park Sung Yong;Lee Doo Hyun;Lee Seok Ho;Kim Tae Hyun;Cho Kwan Ho
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.173-178
    • /
    • 2004
  • Purpose: To compare desimetrically intensity-modulated radiotherapy treatment plans with commercially available multileaf collimators (MLCs) of different leaf width for intracranial lesions. Materials and Methods: Twelve patients with intracranial lesions were treated with BrainLAB's micro-MLCs (mMLCs) and performed with the BrainSCAN ver. 5.2 planning software. They were replanned using the Varian 120 and 80 MLCs. These collimators have minimum leaf width of 3 mm, 5 mm and 10 mm at isocenter, respectively. PTV was $3.3~339.2\textrm{cm}^3$ and the number of beams was 3~7. These three plans were compared with respect to the uniformity and the conformity indices, doses to critical organ and normal tissue. Results: For the uniformity index of the planning target volume (PTV), there were no statistically significant differences between mMLCs and 120 MLCs (p=0.057) and between 120 MLCs and 80 MLCs (p=0.388). However, there was a difference between mMLCs and 80 MLCs (p<0.001). Maximum target dose to the PTV showed no dependency with respect to the leaf width. On the contrary, there were statistically significant differences in the conformity indices between mMLCs and 120 MLCs (p=0.003), between mMLCs and 80 MLCs (p=0.003) and between 120 MLCs and 80 MLCs (p=0.003). The volume of brainstem irradiated to $\geq$70% dose and to $\geq$50% dose was increased as the leaf width of MLCs increased. In particular, the volume of normal tissue irradiated is obviously changed for different leaf width. Volumetric increments for MLCs with leaf widths of 5 mm and 10 mm were 6.3% and 23.2% to the normal tissue irradiated to $\geq$50% dose, and 8.7% and 32.7% to the normal tissue irradiated to $\geq$70% dose, respectively, compared to the volume for MLCs with leaf width of 3 mm. Conclusions: The uniformity index and maximum target dose to the PTV showed no dependency with respect to leaf width of MLCs. However, the conformity index was improved as the leaf width decreased. For the sparing of normal brain tissue, treatment plans with MLCs of 3 mm leaf width is more effective, compared to ones with MLCs of 5 mm and 10 mm leaf widths.

  • PDF

Deep inspiration breath-hold (DIBH) 적용한 림프절이 포함된 왼편 유방암의 방사선 치료계획에 따른 주변 장기 선량 평가

  • Jeong, Da-Lee;Gang, Hyo-Seok;Choe, Byeong-Jun;Park, Sang-Jun;Lee, Geon-Ho;Lee, Du-Sang;An, Min-U;Jeon, Myeong-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • Purpose: On the left side, breast cancer patients have more side effects than those on the right side because of unnecessary doses in normal organs such as heart and lung. DIBH is performed to reduce this. To evaluate the dose of peripheral organs in the left breast cancer including supraclavicular lymph nodes and internal mammary lymph nodes according to the treatment planning method of Conventional Radiation Therapy, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy. Materials and Methods: We performed CT-simulation using free breathing and deep inspiration breath-hold technique for 8 patients including left supraclavicular lymph nodes and internal mammary lymph nodes. Based on the acquired CT images, the contour of the body is drawn and the convention is performed so that $95%{\leftarrow}PTV$, $Dmax{\leftarrow}110%$. Conventional Radiation Therapy used a one portal technique on the supraclavicular lymph node and used a field in field technique tangential beam on the breast. Intensity Modulated Radiation Therapy was composed of 7 static fields. Volumetric Modulated Arc Therapy was planned using 2 ARC with a turning radius of $290^{\circ}$ to $179^{\circ}$. The peripheral normal organs dose was analyzed by referring to the dose volume of Eclipse. Results: By applying the deep inspiration breath-hold technique, the mean interval between the heart and chest wall increased $1.6{\pm}0.6cm$. The mean dose of lung was $19.2{\pm}1.0Gy$, which was the smallest value in Intensity Modulated Radiation Therapy. The V30 (%) of the heart was $2.0{\pm}1.9$, which was the smallest value in Intensity Modulated Radiation Therapy. In the left anterior descending coronary artery, the dose was $25.4{\pm}5.4Gy$, which was the smallest in Intensity Modulated Radiation Therapy. The maximum dose value of the Right breast was $29.7{\pm}4.3Gy$ at Intensity Modulated Radiation Therapy. Conclusion: When comparing the values of surrounding normal organs, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy were applicable values for treatment. Among them, Intensity Modulated Radiation Therapy is considered to be a suitable treatment planning method.

  • PDF