• Title/Summary/Keyword: Dose planning

Search Result 718, Processing Time 0.027 seconds

The Study on Applicability of Semi-conductive Compound for Radioactive Source Tracing Dosimeter in NDT Field (비파괴 검사 분야의 방사성 동위원소 위치추적을 위한 반도체 화합물의 적용 가능성 연구)

  • Shin, Yohan;Han, Moojae;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.39-44
    • /
    • 2019
  • Radiation safety management is being considered very important since radioactive isotopes such as Co-60 and Ir-192 are widely used in fields such as non-destructive test(NDT). In this study, the applicability of Mercury(II) Iodide($HgI_2$) source for tracing system was evaluated. To make sure the unit cell sensor's reliability, we evaluated the electrical properties of the sensor made with $HgI_2$, and then position dependence of the sensor was analyzed and compared with the dose distribution from the planning system. As a result of the evaluation, high reliability of the sensor was shown through the linearity of R-sq > 0.990 and reproducibility of CV < 0.015. In the position dependence evaluation, the maximum value was measured at the isocenter of the sensor and gradually decreased according to the distance. However, the dose distribution data from the planning system was turned out that has difference with that of the sensor up to 30%. This seems to come from the difference between single-point measuring based planning system and area measuring based sensor.

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

Dosimetric Effects of Air Pocket during Magnetic Resonance-Guided Adaptive Radiation Therapy for Pancreatic Cancer

  • Jin, Hyeongmin;Kim, Dong-Yun;Park, Jong Min;Kang, Hyun-Cheol;Chie, Eui Kyu;An, Hyun Joon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART), an emerging technique, is used to address the change in anatomical structures, such as treatment target region, during the treatment period. However, the electron density map used for dose calculation differs from that for daily treatment, owing to the variation in organ location and, notably, air pockets. In this study, we evaluate the dosimetric effect of electron density override on air pockets during online ART for pancreatic cancer cases. Methods: Five pancreatic cancer patients, who were treated with MRgART at the Seoul National University Hospital, were enrolled in the study. Intensity modulated radiation therapy plans were generated for each patient with 60Co beams on a ViewrayTM system, with a 45 Gy prescription dose for stereotactic body radiation therapy. During the treatment, the electron density map was modified based on the daily MR image. We recalculated the dose distribution on the plan, and the dosimetric parameters were obtained from the dose volume histograms of the planning target volume (PTV) and organs at risk. Results: The average dose difference in the PTV was 0.86Gy, and the observed difference at the maximum dose was up to 2.07 Gy. The variation in air pockets during treatment resulted in an under- or overdose in the PTV. Conclusions: We recommend the re-contouring of the air pockets to deliver an accurate radiation dose to the target in MRgART, even though it is a time-consuming method.

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy

  • Gayen, Sanjib;Kombathula, Sri Harsha;Manna, Sumanta;Varshney, Sonal;Pareek, Puneet
    • Radiation Oncology Journal
    • /
    • v.38 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • Purpose: To evaluate the dosimetric variations in patients of head and neck cancer treated with definitive or adjuvant radiotherapy using optimized non-coplanar (ncVMAT) beams with coplanar (cVMAT) beams using volumetric arc therapy. Materials and Methods: Twenty-two patients of head and neck cancer that had received radiotherapy using VMAT in our department were retrospectively analyzed. Each of the patients was planned using coplanar and non-coplanar orientations using an optimized couch angle and fluences. We analyzed the Conformity Index (CIRTOG), Dose Homogeneity Index (DHI), Heterogeneity Index (HIRTOG), low dose volume, target and organs-at-risk coverage in both the plans without changing planning optimization parameters. Results: The prescription dose ranged from 60 Gy to 70 Gy. Using ncVMAT, CIRTOG, DHI and HIRTOG, and tumor coverage (ID95%) had improved, low dose spillage volume in the body V5Gy was increased and V10Gy was reduced. Integral dose and intensity-modulated radiation therapy factor had increased in ncVMAT. In the case of non-coplanar beam arrangements, maximum dose (Dmax) of right and left humeral head were reduced significantly whereas apex of the right and left lung mean dose were increased. Conclusion: The use of ncVMAT produced better target coverage and sparing of the shoulder and soft tissue of the neck as well as the critical organ compared with the cVMAT in patients of head and neck malignancy.

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas (뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.354-359
    • /
    • 2010
  • The purpose of this study is to verify the dosimetric effect on real PTV (planning target volume) coverage and safety of OARs (organs at risk) at various image fusion protocol-based radiosurgery plan for pituitary adenomas. Real PTV coverage and its variation was acquired and maximum dose and the volume absorbing above threshold dose were also measured for verifying the safety of optic pathway and brainstem. The protocol that can reduce superior-inferior uncertainty by using both axial and coronal MR (magnetic resonance) image sets shows relatively lower values than that of case using only axial image sets. As a result, the image fusion protocol with both axial and coronal image sets can be beneficial to generate OAR-weighted radiosurgery plan.

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.

Dosimetric Evaluations of HyperArc and RapidArc in Stereotactic Radiosurgery for a Single Brain Metastasis

  • So-Yeon Park;Noorie Choi;Na Young Jang
    • Progress in Medical Physics
    • /
    • v.35 no.2
    • /
    • pp.36-44
    • /
    • 2024
  • Purpose: This study assessed and compared the dosimetric performance of HyperArc and RapidArc in stereotactic radiosurgery (SRS) for a single brain metastasis. Methods: Twenty patients with intracranial brain metastases, each presenting a distinct target volume, were retrospectively selected. Subsequently, volumetric modulated arc therapy (VMAT) plans were designed using RapidArc (VMATRA) and HyperArc (VMATHA) for each patient. For planning comparisons, dose-volumetric histogram (DVH) parameters for planning target volumes (PTVs) and normal brain regions were computed across all VMAT plans. Subsequently, their total monitor units (MUs), total beam-on times, and modulation complexity scores for the VMAT (MCSv) were compared. A statistical test was used to evaluate the dosimetric disparities in the DVH parameters, total MUs, total beam-on times, and MCSv between the VMATHA and VMATRA plans. Results: For the PTVs, VMATHA presented a higher homogeneity index (HI) than VMATRA. Moreover, VMATHA presented significantly smaller gradient index (GI) values (P<0.001) than VMATRA. Thus, VMATHA demonstrated better performance in the DVH parameters for the PTV than VMATRA. For normal brain tissues, VMATHA presented lower volume receiving 50% of the prescription dose and V2Gy to the normal brain tissues than VMATRA (P<0.0001). While the total MUs required for VMATHA was significantly higher than those for VMATRA, the total beam-on time for VMATHA was superior to that for VMATRA. Conclusions: Thus, VMATHA exhibited superior performance in achieving rapid dose fall-offs (as indicated by the GI) and a higher HI at the PTV compared to VMATRA in brain SRS. This advancement positions HyperArc as a significant development in the field of radiation therapy, offering optimized treatment outcomes for brain SRS.

Efficacy of CT-aided Radiotherapy Planning of Head and Neck Tumor (두경부악성종양(頭頸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관(關)한 연구(硏究))

  • Cho, Chul Koo;Koh, Kyoung Hwan;Chang, Kee Hyun;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1983
  • CT scans obtained on 15 patients of head and neck malignant tumors were evaluated for their utility in ratiotherapy treatment planning. To evaluate the advantage of incorporating CT scans in radiotherapy treatment planning of head and neck malignant tumors, the dose distributions of treatment plan with and without CT scan were compared in 15 patients. And then the dose distributions of the first and second treatment plan were compared. 1. Tumor extend and localization were clearly delineated on CT scan in 12 of 15 cases (80%), suggestive in 2 (13.3%), and not seen in only one (6.7%) which had been in the postoperative state. 2. Tumor coverage after CT scan was adequate in 14 of 15 cases (93.3%) and not in only one. In one case of inadequate tumor coverage the target volume lay inside the field but reached within 0.5cm of the field margin (marginal miss). 3. The volume of normal tissue irradiated was reduced after CT scan in 12 of 15 cases (80%), increased in 1 (6.7%) and not changed in 2 (13.3%). 4. We could maximize the local control of disease and minimize unnecessary morbidity by delineating the location and extent of tumor and normal tissue with CT for treatment plannings.

  • PDF