• 제목/요약/키워드: Dose mapping

검색결과 20건 처리시간 0.026초

Gaussian process approach for dose mapping in radiation fields

  • Khuwaileh, Bassam A.;Metwally, Walid A.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1807-1816
    • /
    • 2020
  • In this work, a Gaussian Process (Kriging) approach is proposed to provide efficient dose mapping for complex radiation fields using limited number of responses. Given a few response measurements (or simulation data points), the proposed approach can help the analyst in completing a map of the radiation dose field with a 95% confidence interval, efficiently. Two case studies are used to validate the proposed approach. The First case study is based on experimental dose measurements to build the dose map in a radiation field induced by a D-D neutron generator. The second, is a simulation case study where the proposed approach is used to mimic Monte Carlo dose predictions in the radiation field using a limited number of MCNP simulations. Given the low computational cost of constructing Gaussian Process (GP) models, results indicate that the GP model can reasonably map the dose in the radiation field given a limited number of data measurements. Both case studies are performed on the nuclear engineering radiation laboratories at the University of Sharjah.

Development of a One-step Two-site Enzyme Immunoassay for Measuring Human Alpha-fetoprotein by Eliminating Hook-effect

  • Kim, Se-Ho
    • BMB Reports
    • /
    • 제34권1호
    • /
    • pp.47-50
    • /
    • 2001
  • A one-step, two-site enzyme immunoassay was developed for measuring human alpha-fetoprotein (AFP) in serum and amniotic fluid using monoclonal antibodies (McAb) by eliminating the high-dose hook effect. Three McAbs that recognize different epitopes were selected among 16 different clones on the basis of epitope mapping, two for immobilization and one for horseradish peroxidase conjugation. This one-step immunoassay system is more convenient and rapid compared to a conventional two-step sandwich immunoassay system. It did not exhibit the hook effect to around 2.7 mg/ml of AFP, which is probably one of the highest concentrations of AFP in the serum. The dose-response curve of the system was linear to 500 mg/ml of AFP and the system could differentiate as low as 1 mg/ml of AFP The intra- and inter-assay variations were in an acceptable range; 95~104% and 97~105% respectively Its correlation with other commercial systems was around 95%.

  • PDF

히스토그램 변형을 이용한 HDR 영상 렌더링을 위한 인지기반 톤 맵핑 기법 (Perception-Based Tone Mapping Technique for Rendering HDR Image Using Histogram Modification)

  • 김원균;하창우;정제창
    • 한국통신학회논문지
    • /
    • 제38A권11호
    • /
    • pp.919-927
    • /
    • 2013
  • 본 논문에서는 HDR (high dynamic range) 영상 렌더링을 위한 히스토그램 변형 기법을 이용한 인지기반 톤 맵핑(tone mapping) 기법을 제안한다. HDR 톤 맵핑 알고리듬은 넓은 동적 영역을 갖는 영상을 LDR (low dynamic range) 영상 장치에 표현하기 위해 사용된다. 인간의 시각특성을 이용한 톤 맵핑 알고리듬은 상당히 효과적이지만 고정된 형태의 맵핑 함수를 사용하기 때문에 모든 영상에서 동일한 성능을 얻지 못한다. 제안하는 방법은 인지기반 톤 맵핑 함수와 히스토그램 변형기법을 적용하여 HDR 영상의 동적 영역을 압축한다. 인지기반 톤 맵핑 함수를 이용해서 원 영상의 히스토그램을 제한하고 보상과정을 통해서 적응적인 톤 맵핑 함수를 얻을 수 있다. 이는 화소값에 따라 서로 다른 제약조건들을 사용함으로써 contrast를 향상시킬 뿐만 아니라 원 영상의 디테일도 보존한다. 또한, 히스토그램 변형기법을 사용함으로써 과도한 히스토그램 평활화로 인한 왜곡을 개선할 수 있고, 더욱이 제어파라미터를 이용하여 영상의 contrast를 조정할 수 있다. 시뮬레이션 및 실험을 통해 주관적 및 객관적 성능을 비교하고 기존 방법에 비해 제안한 방법이 우수함을 입증한다.

측량 및 매핑 방법의 비용 대 효과 분석 (The Benefit-Cost Evaluation of the Surveying and Mapping Methods)

  • 박홍기
    • 한국측량학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2001
  • 기술적인 프로젝트를 수행하는 기관들은 전문가들의 도움을 받는 것이 보편화되어가고 있다. 프로젝트를 사전 검토하는 전문가들은 정보화 기술과 측량 및 매핑의 변화된 기술과 함께 경제적인 방법에 대한 분야에 대한 전문적인 지식이 있어야 한다. 토털스테이션, GPS, 정사사진, 수치지도 및 위성 리모트센싱과 같은 새로운 측량 및 매핑 방법은 과거의 측량 개념을 송두리째 바꾸어버렸다. 또한 매핑에 대한 기술은 지난 50년 동안 기계식에서 해석적 그리고 수치적으로 크게 변화되었다. 이제 측량 및 매핑 방법들의 적절한 선택은 특정한 기술의 사용보다는 비용과 효과 측면에서의 결정사항이 되고 있다. 예를 들어 GPS측량기는 종래의 측량기기보다 더 비싸지만 비용효율적인 측면에서 장점을 제공하고 있다. 본 연구에서는 측량 및 매핑 프로젝트에서의 비용인자와 효과인자를 독립적으로 평가하였고, 비용/효과 비(B/C비)를 평가모델에 사용하여 각 측량방법의 비용 효과를 비교하였다. 측량 및 매핑 방법들의 비용 대 효과 모델은 전체 프로젝트에서 경제적인 결과를 얻을 수 있을 것이다.

  • PDF

ANALYSIS BY SYNTHESIS FOR ESTIMATION OF DOSE CALCULATION WITH gMOCREN AND GEANT4 IN MEDICAL IMAGE

  • Lee, Jeong-Ok;Kang, Jeong-Ku;Kim, Jhin-Kee;Kim, Bu-Gil;Jeong, Dong-Hyeok
    • Journal of Radiation Protection and Research
    • /
    • 제37권3호
    • /
    • pp.146-148
    • /
    • 2012
  • The use of GEANT4 simulation toolkit has increased in the radiation medical field for the design of treatment system and the calibration or validation of treatment plans. Moreover, it is used especially on calculating dose simulation using medical data for radiation therapy. However, using internal visualization tool of GEANT4 detector constructions on expressing dose result has deficiencies because it cannot display isodose line. No one has attempted to use this code to a real patient's data. Therefore, to complement this problem, using the result of gMocren that is a three-dimensional volume-visualizing tool, we tried to display a simulated dose distribution and isodose line on medical image. In addition, we have compared cross-validation on the result of gMocren and GEANT4 simulation with commercial radiation treatment planning system. We have extracted the analyzed data of dose distribution, using real patient's medical image data with a program based on Monte Carlo simulation and visualization tool for radiation isodose mapping.

Estimation of natural radionuclide and exhalation rates of environmental radioactive pollutants from the soil of northern India

  • Devi, Vandana;Chauhan, Rishi Pal
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1289-1296
    • /
    • 2020
  • The estimation of radioactivity level is vital for population health risk assessment and geological point of view and can be evaluated as rate of exhalation and source concentration (226Ra, 232Th and 40K). The present study deals with the soil samples for investigation of radionuclides content and exhalation rates of radon -thoron gas from different sites in northern Haryana, India. Absorbed dose and associated index estimated in the present study are the measures of environmental radioactivity to inhalation dose. Effective doses received by different tissues and organs by considering different occupancy and conditions are also measured. Exhalation rates of radon and thoron are measured with active scintillation monitors based on alpha spectroscopy namely scintillation radon (SRM) and thoron (STM) monitors respectively. Sample height was optimized before measurement of thoron exhalation rate using STM. Average values of radon and thoron exhalation are found 16.6 ± 0.7 mBqkg-1h-1 and 132.1 ± 2.6 mBqm-2s-1 respectively. Also, a simple approach was also adopted, to evaluate the thoron exhalation which accomplished a lot of challenges, the results are compared with the data obtained experimentally. The study is useful in the nationwide mapping of radon and thoron exhalation rates for understanding the environmental radioactivity status.

Intent to Use a Smartphone Application for Radiation Monitoring in Correlation with Anxiety about Exposure to Radiation, Recognition of Risks, and Attitudes toward the Use of Radiation

  • Han, Eunkyoung;Rott, Carsten;Hong, Seung-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.205-211
    • /
    • 2017
  • Background: Radiation is used in a variety of areas, but it also poses potential risks. Although radiation is often used with great effectiveness in many applications, people perceive potential risks associated with radiation and feel anxious about the possibility of radiation exposure. Various methods of measuring radiation doses have been developed, but there is no way for the general public to measure their doses with ease. Currently, many people use smartphones, which provide information about the location of an individual phone through network connections. If a smartphone application could be developed for measuring radiation dosage, it would be a very effective way to measure individuals' radiation doses. Thus, we conducted a survey study to assess the social acceptance of such a technology by the general public and their intent to use that technology to measure radiation doses, as well as to investigate whether such an intention is correlated with anxiety and attitudes toward the use of radiation. Materials and Methods: A nationwide online survey was conducted among 355 Koreans who were 20 years old or older. Results and Discussion: Significant differences were found between the genders in attitudes, perceptions of radiation risk, and fears of exposure to radiation. However, a significant difference according to age was observed only in the intent to use a smartphone dose measurement application. Attitudes towards the use of radiation exerted a negative effect on radiation risk perception and exposure anxiety, whereas attitudes towards the use of radiation, risk perception, and anxiety about exposure were found to have a positive impact on the intent to use a smartphone application for dose measurements. Conclusion: A survey-based study was conducted to investigate how the general public perceives radiation and to examine the acceptability of a smartphone application as a personal dose monitoring device. If such an application is developed, it could be used not only to monitor an individual's dose, but also to contribute to radiation safety information infrastructure by mapping radiation in different areas, which could be utilized as a useful basis for radiation research.

소형 반도체 센서모듈 기반 방사선정보 원격 가시화기술 연구 (Remote Visualization of Radiation Information based on small Semiconductor Sensor Modules)

  • 이남호;황영관;허용석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.876-879
    • /
    • 2012
  • 본 논문에서는 고준위 방사선구역의 방사능준위 분포를 원격에서 안전하게 측정할 수 있는 방사선량 측정기술의 구현에 관해 논하였다. 설계된 방사선량 매핑장치는 고준위 방사선환경에 위치하는 방사선 노드와 원격 전송된 방사선 정보를 그래픽화된 공간위치상에 가시화하는 방사선 스테이션으로 구성된다. 다수의 방사선 노드는 사고환경의 방사선량 정보를 pMOSFET 센서로 센싱하여 무선정보로 송신하는 기능을 수행하고 방사선 스테이션에서는 방사선 노드로 부터 수신된 방사선량 정보와 위치정보를 결합하여 현장을 모사한 그래픽 공간상에 실측 방사선분포 정보 가시화하게 된다. 제작된 방사선 노드를 실험실 공간에 부착하고 원격 방사선 정보가시화 프로그램을 통하여 방사선정보 매핑하는 실험을 통하여 원격방사선가시화 장치의 기능을 검증하였다.

  • PDF

Image Encryption Using Phase-Based Virtual Image and Interferometer

  • Seo, Dong-Hoan;Kim, Soo-Joong
    • Journal of the Optical Society of Korea
    • /
    • 제6권4호
    • /
    • pp.156-160
    • /
    • 2002
  • In this paper, we propose an improved optical security system using three phase-encoded images and the principle of interference. This optical system based on a Mach-Zehnder interferometer consists of one phase-encoded virtual image to be encrypted and two phase-encoded images, en-crypting image and decrypting image, where every pixel in the three images has a phase value of '0'and'$\pi$'. The proposed encryption is performed by the multiplication of an encrypting image and a phase-encoded virtual image which dose not contain any information from the decrypted im-age. Therefore, even if the unauthorized users steal and analyze the encrypted image, they cannot reconstruct the required image. This virtual image protects the original image from counterfeiting and unauthorized access. The decryption of the original image is simply performed by interfering between a reference wave and a direct pixel-to-pixel mapping image of the en crypted image with a decrypting image. Computer simulations confirmed the effectiveness of the proposed optical technique for optical security applications.