• Title/Summary/Keyword: Dose coefficient

Search Result 267, Processing Time 0.023 seconds

Development of a novel in vitro SPF evaluation method (새로운 in vitro SPF측정법 개발)

  • 오선진;김진준
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.2
    • /
    • pp.57-72
    • /
    • 1995
  • We have recently developed a novel in vitro SPF evaluation method with a high correlation coefficient (r=0.93) to in vivo SPF values(test sunscreen formulas : cress m, foundation). In this method, the in vitro SPF value was determined by the ratio of the time taken to achieve the minimal erythema dose with and without the sunscreens applied. We also reviewed the dilution and thin-layer methods for in vitro SPF evaluation, and investigated the relationship between irradiance(3$\times$10-3 2.5x 10-5W/cm2) and the degree of erythema. The degree of erythema was similar if t he radiation exposure(40mJ/cm2) was kept constant. It was obtained more than 0.90 correlation coefficient when it was compared the results by our new method with those from SPF-290 analyzer (Optometries, U.S.A.).

  • PDF

Comparison of the effects of irradiation on iso-molded, fine grain nuclear graphites: ETU-10, IG-110 and NBG-25

  • Chi, Se-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2359-2366
    • /
    • 2022
  • Selecting graphite grades with superior irradiation characteristics is important task for designers of graphite moderation reactors. To provide reference information and data for graphite selection, the effects of irradiation on three fine-grained, iso-molded nuclear grade graphites, ETU-10, IG-110, and NBG-25, were compared based on irradiation-induced changes in volume, thermal conductivity, dynamic Young's modulus, and coefficient of thermal expansion. Data employed in this study were obtained from reported irradiation test results in the high flux isotope reactor (HFIR)(ORNL) (ETU-10, IG-110) and high flux reactor (HFR)(NRL) (IG-110, NBG-25). Comparisons were made based on the irradiation dose and irradiation temperature. Overall, the three grades showed similar irradiation-induced property change behaviors, which followed the historic data. More or less grade-sensitive behaviors were observed for the changes in volume and thermal conductivity, and, in contrast, grade-insensitive behaviors were observed for dynamic Young's modulus and coefficient of thermal expansion changes. The ETU-10 of the smallest grain size appeared to show a relatively smaller VC to IG-110 and NBG-25. Drastic decrease in the difference in thermal conductivity was observed for ETU-10 and IG-110 after irradiation. The similar irradiation-induced properties changing behaviors observed in this study especially in the DYM and CTE may be attributed to the assumed similar microstructures that evolved from the similar size coke particles and the same forming method.

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Characterization and Comparison of Doping Concentration in Field Ring Area for Commercial Vertical MOSFET on 8" Si Wafer (8인치 Si Power MOSFET Field Ring 영역의 도핑농도 변화에 따른 전기적 특성 비교에 관한 연구)

  • Kim, Gwon Je;Kang, Ye Hwan;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.271-274
    • /
    • 2013
  • Power Metal Oxide Semiconductor Field Effect Transistor's (MOSFETs) are well known for superior switching speed, and they require very little gate drive power because of the insulated gate. In these respects, power MOSFETs approach the characteristics of an "ideal switch". The main drawback is on-resistance RDS(on) and its strong positive temperature coefficient. While this process has been driven by market place competition with operating parameters determined by products, manufacturing technology innovations that have not necessarily followed such a consistent path have enabled it. This treatise briefly examines metal oxide semiconductor (MOS) device characteristics and elucidates important future issues which semiconductor technologists face as they attempt to continue the rate of progress to the identified terminus of the technology shrink path in about 2020. We could find at the electrical property as variation p base dose. Ultimately, its ON state voltage drop was enhanced also shrink chip size. To obtain an optimized parameter and design, we have simulated over 500 V Field ring using 8 Field rings. Field ring width was $3{\mu}m$ and P base dose was $1e15cm^2$. Also the numerical multiple $2.52cm^2$ was obtained which indicates the doping limit of the original device. We have simulated diffusion condition was split from $1,150^{\circ}C$ to $1,200^{\circ}C$. And then $1,150^{\circ}C$ diffusion time was best condition for break down voltage.

Dose coefficients of mesh-type ICRP reference computational phantoms for external exposures of neutrons, protons, and helium ions

  • Yeom, Yeon Soo;Choi, Chansoo;Han, Haegin;Shin, Bangho;Nguyen, Thang Tat;Han, Min Cheol;Kim, Chan Hyeong;Lee, Choonsik
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1545-1556
    • /
    • 2020
  • Recently, the International Commission on Radiological Protection (ICRP) has developed the Mesh-type Reference Computational Phantoms (MRCPs) for adult male and female to overcome the limitations of the current Voxel-type Reference Computational Phantoms (VRCPs) described in ICRP Publication 110 due to the limited voxel resolutions and the nature of voxel geometry. In our previous study, the MRCPs were used to calculate the dose coefficients (DCs) for idealized external exposures of photons and electrons. The present study is an extension of the previous study to include three additional particles (i.e., neutrons, protons, and helium ions) into the DC library by conducting Monte Carlo radiation transport simulations with the Geant4 code. The calculated MRCP DCs were compared with the reference DCs of ICRP Publication 116 which are based on the VRCPs, to appreciate the impact of the new reference phantoms on the DC values. We found that the MRCP DCs of organ/tissue doses and effective doses were generally similar to the ICRP-116 DCs for neutrons, whereas there were significant DC differences up to several orders of magnitude for protons and helium ions due mainly to the improved representation of the detailed anatomical structures in the MRCPs over the VRCPs.

Synthesis and In Vitro Properties of Prednisolone 21-Sulfate Sodium as a Colon-Specific Prodrug of Prednisolone

  • Doh, Min-Ju;Jung, Yun-Jin;Kim, In-ho;Kong, Hye-Sik;Kim, Young-Mi
    • Archives of Pharmacal Research
    • /
    • v.26 no.4
    • /
    • pp.258-263
    • /
    • 2003
  • Colon-specific delivery of glucocorticoids is highly desirable for the efficient treatment of inflammatory bowel disease. We synthesized prednisolone 21-sulfate sodium (PDS) as a colon-specific prodrug of prednisolone (PD) and investigated its properties using rats as test animals. We expected that introduction of sulfate ester as a sodium salt might increase the hydrophilicity and restrict the absorption in the GI tract. If PDS is stable and nonabsorbable in the upper intestine, it will be delivered to the colon as an intact form, where it hydrolyze by the sulfatase to release PD. Compared with PD, the solubility of PDS increased and the apparent partition coefficient decreased greatly. PDS was stable on incubation with pH 1.2 and 6.8 buffer solutions and with the contents of the stomach and small intestine. On incubation with the cecal contents, PDS decreased to 9.6% of the dose in 10 h producing PD. The amount of PD increased to give a maximum 54% of the dose and decreased. As a control, when PD was incubated with the cecal contents, it decreased to 29% of the dose in 8 h, which implied that reduction of PD proceeded under such conditions. These results suggested that hydrolysis of PDS took place to produce and accumulate PD, which decreased by reduction as the incubation period extended. Our results suggested that PDS can be a promising colon-specific prodrug of PD, and sulfate ester group might serve as a potential colon-specific promoiety, especially for the drugs which are resistant to reduction in the colon.

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

Modelling and packed bed column studies on adsorptive removal of phosphate from aqueous solutions by a mixture of ground burnt patties and red soil

  • Rout, Prangya R.;Dash, Rajesh R.;Bhunia, Puspendu
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.231-251
    • /
    • 2014
  • The present study examines the phosphate adsorption potential and behavior of mixture of Ground Burnt Patties (GBP), a solid waste generated from cooking fuel used in earthen stoves and Red Soil (RS), a natural substance in fixed bed column mode operation. The characterization of adsorbent was done by Proton Induced X-ray Emission (PIXE), and Proton Induced ${\gamma}$-ray Emission (PIGE) methods. The FTIR spectroscopy of spent adsorbent reveals the presence of absorbance peak at $1127cm^{-1}$ which appears due to P = O stretching, thus confirming phosphate adsorption. The effects of bed height (10, 15 and 20 cm), flow rate (2.5, 5 and 7.5 mL/min) and initial phosphate concentration (5 and 15 mg/L) on breakthrough curves were explored. Both the breakthrough and exhaustion time increased with increase in bed depth, decrease in flow rate and influent concentration. Thomas model, Yoon-Nelson model and Modified Dose Response model were used to fit the column adsorption data using nonlinear regression analysis while Bed Depth Service Time model followed linear regression analysis under different experimental condition to evaluate model parameters that are useful in scale up of the process. The values of correlation coefficient ($R^2$) and the Sum of Square Error (SSE) revealed the Modified Dose Response model as the best fitted model to the experimental data. The adsorbent mixture responded effectively to the desorption and reusability experiment. The results of this finding advocated that mixture of GBP and RS can be used as a low cost, highly efficient adsorbent for phosphate removal from aqueous solution.

The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT (두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향)

  • Ki-Cheon Um;Gha-Jung Kim;Geum-Mun Back
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

Evaluation of RPL Glass Dosimeter Characteristics and Uncertainty Evaluation of Reading Correction Factors (유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가)

  • Seong-Yun Mok;Yeong-Rok Kang;Hyo-Jin Kim;Yong-Uk Kye;Hyun An
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2023
  • In this study, basic characteristics such as reproducibility, linearity, and directionality of RPL glass dosimeters were evaluated to improve the reliability of dose evaluation through RPL glass dosimeters, and uncertainty elements such as sensitivity by glass element and magazine slot sensitivity were evaluated. Using a mathematical model to calibrate the measured values of the RPL glass dosimeter, the measurement uncertainty was calculated assuming an example. As a result of the characteristic evaluation, the RPL glass dosimeter showed excellent performance with a standard deviation of ±1% (1 SD) for the reproducibility of the reading process, a coefficient of determination for linearity of 0.99997. And the read-out of the RPL glass dosimeter are affected by the circular rotation direction of the glass dosimeter during irradiation, fading according to the period after irradiation, the number of laser pulses of the reader, and response degradation due to repeated reading, it is judged that measurement uncertainty can be reduced by irradiation and reading in consideration of these factors. In addition, it was confirmed that the dose should be determined by calculating the correction factors for the sensitivity of each element and, the sensitivity of each reading magazine slot. It is believed that the reliability of dosimetry using glass dosimeters can be improved by using a mathematical model for correction of glass dosimeter readings and calculating measurement uncertainty.