• Title/Summary/Keyword: Doppler flow velocity

Search Result 329, Processing Time 0.021 seconds

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

An Experimental Study on the Effect of a Hydraulic Structure on the Three-dimensional Flow in a Meandering Channel (만곡수로 내 수리구조물 설치에 따른 3차원 흐름 특성변화 실험 연구)

  • Lee, Dong Hun;Kim, Su Jin;Kang, Seokkoo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.635-645
    • /
    • 2015
  • The objective of this study is to examine the three-dimensional turbulent flows occurring in the meandering channel with presence of a groyne. A series of laboratory experiments are carried out in a meandering channel with trapezoidal cross sections. The channel is a 24.4 m long, 1.5 m wide, and the bottom slope in the longitudinal direction is 0.02. Two cases with and without the groyne are considered in the experiment. Three-dimensional velocity fields are measured using an acoustic Doppler velocimetry (ADV) at approximately sixty locations in each cross section. The measured velocity fields are averaged in time, and the time-averaged flow revealed that the mean velocity magnitude along the outer bank of the channel was reduced significantly and the direction of the primary flow was directed toward the center of the channel due to the presence of the groyne.

Changes in Posterior Cerebral Artery Blood flow Velocity Following Head rotation and body Positioning (머리회전과 측정자세에 따른 뒤대뇌동맥의 혈류속도 변화)

  • Park, Min-Chull;Kim, Jong-Soon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 2015
  • PURPOSE: Vertebrobasilar insufficiency (VBI) should be carefully assessed in patient for whom manipulation of the cervical spine is to be undertaken. The purpose of this study was to investigate the changes in posterior cerebral artery blood flow velocity following head and body positioning by transcranial doppler ultrasonography (TCD) in healthy subjects. METHODS: Twenty two healthy female (mean age $20.77{\pm}1.30yrs.$) participants volunteered to participate in the study. None of the participants had a history of neck pain or headache within the last 6 months. To evaluate the cerebral blood flow, we measured the mean flow velocity of the posterior cerebral artery unilaterally (right side). The blood flow velocity was measured under 3 different head positions (in a neutral head position, ipsilateral head rotation and contralateral head rotation position) and 2 different body conditions (supine position and sitting position). RESULTS: The mean blood flow velocity of posterior cerebral artery was decreased in body positioning from supine to sitting (p<.05), but the decreased rate of blood flow velocity in posterior cerebral artery did not change significantly between ipsilateral head rotation and contralateral head rotation (p>.05). CONCLUSION: These result of our study show that body positioning (sitting and supine) affect the blood flow velocity in posterior cerebral artery.

Velocity and Spray Characteristics under Swirl Flows in a Model Combustor (모델연소기 선회유동장에서의 속도 및 분무특성)

  • Bae, C.S.;Lee, D.H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.2
    • /
    • pp.42-50
    • /
    • 1998
  • The effect of swirl flows un the fuel spray characteristics were investigated for various swillers in a model combustor. The interaction between the flow field and fuel spray in the main combustion tone made by frontal devices including fuel injection nozzles and swirlers. which were characterized by flow velocities, fuel droplet sizes and their distributions which were measured by APV(Adaptive Phase/Doppler Velocimetry) under atmospheric condition at 320cc/min kerosine fuel flow and 0.04kg/sec air supply. A dual swirler with circumferential two-stage swirl vanes of $40^{\circ}\;and\;45^{\circ}$ vanes in different directions and two single-stage swillers of $40^{\circ}$ vanes with 12 and 16 vanes were tested. It was found that the dual swirler has the largest recirculating zone with highest reverse flow velocity. The strongest swirl flow was found at the boundary of recirculation zone. Small fuel droplets were observed in the main axial stream and inside the recirculation zone when swirling flow field were generated by the frontal devices. These findings could give the tips on the optimal design of frontal devices to realize low emissions in gas turbine combustion.

  • PDF

Study on the Effect of Swirl Flow on Spray Characteristics (스월유동이 분무특성에 미치는 영향에 관한 연구)

  • Choi, S.H.;Jeon, C.H.;Chang, Y.J.
    • Journal of ILASS-Korea
    • /
    • v.7 no.1
    • /
    • pp.14-20
    • /
    • 2002
  • It is well known that the flow and spray characteristics is critical factor on the performance and emission of a direct injection diesel engine. So this study aims to investigate the interaction of flow and spray characteristics. At first, in cylinder flow distributions in swirl adaptor for 4-valve cylinder head of DI Diesel engine were investigated under steady conditions for different SCV angles mounted on the cylinder head with steady rig test and 2-D LDV. And the in-cylinder flow was quantified in terms of mean flow coefficient and swirl ratio/tumble ratio. It was found that the swirl ratio is controlled between 2.3 and 3.8. Then spray characteristics of the intermittent injection were investigated. PDA system was utilized for measurement of a droplet size and velocity. The analyses of the PDA results are carried out with Time Dividing Method. It was found that there is a correlation between the swirl flow and SMD. The droplet size and the velocity were nearly constant value with each SCV angle. And the swirl ratio is higher, SMD smaller. The swirl ratio was helpful factor to the atomization of droplet.

  • PDF

The Measurement of Blood Flow of Anterior Cerebral Artery in Premature Newborns Using Duplex Doppler Ultrasonography (이중 초음파 검사를 이용한 미숙아의 전 뇌동맥 혈류 측정)

  • Hwang, Mi-Soo;Bae, Kyeung-Kug;Lee, Jae-Kyo
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.77-84
    • /
    • 1997
  • We measured the blood flow velocity of the anterior cerebral artery via anterior fontanelle approach of fifty five preterm neonates with duplex Doppler sonography and analyzed the waveform and calculated pulsatility index, resistive index. Intracranial velocities and pulsatility indexes were increased with increasing gestational age, birth weight, and age of the neonate, but resistive indices decreased. In sick babies, characteristic resistive index increment were seen in patients with intraventricular hemorrhage, but no statistical difference was seen in patients with respiratory distress syndrome. Our results suggest that duplex Doppler sonography is a useful noninvasive means of monitoring cerebrohemodynamics in normal preterm neonates and flow change of sick babies.

  • PDF

Effect of Paekoe(GV20) Acupuncture on Cerebral Blood Flow (백회혈 자침이 뇌혈류에 미치는 영향)

  • Lee Hong-Min;Cheong Byung-Shik;Yun Hyoung-Seok;Cho Seong-Gyu;Lee Sang-Hoon;Jun Hyung-Joon;Nam Sang-Soo;Kim Yong-Suk;Lee Joo-Hyung
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.105-113
    • /
    • 2001
  • Objective : This study was performed to evaluate the effect of acupuncture on cerebral blood flow by Transcranial Doppler Ultrasonography(TCD) Method : Monitoring of TCD was examined in 11 healthy women volunteer(mean $age:\;24.5{\pm}2.9\;\;years$) before, during and after acupuncture on Paekoe(GV20). Mean velocity, pulsatility index, systolic velocity and diastolic velocity values are analyzed from DWL. MDX4 at different depths of both middle cerebral artery. Results : The results showed a significant(p<0.05; Friedman test & Wilcoxon signed ranks test) increase in mean velocity, systolic velocity and diastolic velocity decrease in pulsatility index, which was measured at different depths of both middle cerebral artery. Conclusion : These results suggest that acupuncture could have a specific effect on cerebral blood flow.

  • PDF

A study on the pulsatile flow characteristics of Newtonian and non-Newtonian fluids in the bifurcated tubes (분기관내 뉴턴유체와 혈액의 맥동유동특성에 관한 연구)

  • Seo, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3607-3619
    • /
    • 1996
  • Experimental and numerical studies for three-dimensional pulsatile flows are conducted to investigate the flow characteristics in the bifurcated tubes. Velocity measurements in experimental study were made by both Pulsed Doppler Ultrasound(PDU) machine and Laser Doppler Anemometer(LDA) system. Glycerin is used for experimental study. Experimental results are used to verify the results of the numerical simulation. Flow characteristics of Newtonian fluid and blood in the bifurcated tubes under the steady and pulsatlie flows are numerically investigated. Finite volume method is employed for three-dimensional numerical simulations. Blood is considered as a non-Newtonian fluid and the constitutive equation of blood is used for the numerical analysis. Numerical analyses are focused on the flow patterns for various branch angles ranging from 30.deg. to 90.deg. and diameter ratios such as 1.0, 0.8, and 0.6. Pulsatile flow characteristics of blood are compared with those of Newtonian fluid. Parameter effects on axial velocity, pressure and wall shear stress distribution along the bifurcated tubes are discussed in terms of the branch angle, diameter ratio, and Reynolds number.

An Experimental Study of Flow Fields in an Optical Disc Drive (광 디스크 드라이브 내부 유동장에 관한 실험적 연구)

  • Jung, Ji-Won;Cho, Hyung-Hee;Choi, Myung-Ryul;Seong, Pyoung-Yong;Lee, Kyoung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1789-1794
    • /
    • 2004
  • The present study investigates flow characteristics in an optical disc drive. Detailed knowledge of the flow characteristics is essential to analyze flow-induced noise and vibration, forced convection and flow friction loss. The ODD used in the personal computer is used for the experiment and rotating velocity of disc is under the 4500 rpm. Time-resolved velocity components and velocity spectrum are obtained using the laser Doppler anemometry (LDA). The results show that the front holes reduce now-induced noise and the position of pickup body affects flow near the window. In addition, il is possible for cooling of heat sources in an optical disc drive through measuring the flow fields under the tray.

  • PDF

Effects of Stenting Shapes on the Wall Shear Stress in the Angulated Coronary Stenosis (협착된 관상동맥에 시술된 스텐트형상이 벽면 전단응력에 미치는 영향)

  • Cho, Min-Tae;Suh, Sang-Ho;Yoo, Sang-Sin;Keun, Huk-Moon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.219-222
    • /
    • 2001
  • The objective of the present study is to evaluate the effects of the stenting shapes on flow velocity and wall shear stress in angulated coronary stenosis by computer simulation. Coronary angiogram and Doppler ultrasound measurement in the patients with angulated coronary stenosis were obtained. Inlet wave velocity distribution obtained from in vivo intracoronary Doppler data was used for the numerical simulation. Spatial pattern of blood flow velocity and recirculation area were drawn through out the selected segment of coronary models. Wall shear stresses in the intracoronary stent models were calculated from three-dimensional computer simulation. A negative shear stress region, which is consistent with re-circulation area on flow pattern, was noted on the inner wall of post-stenotic area of pre-stenting model. The negative shear stress was disappeared after stenting. Shear stress in the post-stenting model was markedly reduced up to about two orders of magnitude compared to that of the pre-stenting model.

  • PDF