• Title/Summary/Keyword: Door Module

Search Result 57, Processing Time 0.03 seconds

Design and Implementation of a Sensor Node for Out-Door Environmental Monitoring (옥외 환경 모니터링을 위한 센서노드 설계 및 구현)

  • Son, Jae-Hyun;Cho, Yang-Haeng;Kim, Je-Hong;Joo, Young-Suk;So, Sun-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • In this paper, we described a design and implementation of a sensor node for environmental monitoring. The main focus of design for sensor nodes is to isolate MCU for treating sensors from the RF module for considering various communication environment. The second is to make the interface between MCU and varity of sensor. In addition, we choose a narrow band communication module, cc1020, for the admittance of Korea government communication law. We also use a uC/OS-II as an operating system which is famous for 8bit MCUs. We showed that the communication performance is sufficient to use the communication module in a out-door environment through several experiments in that it is possible to transmit between 100m distance through experiments in a mountain.

Autonomous mobile robot yamabico and its ultrasonic range finding module

  • Song, Minho;Yuta, Shinichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.711-714
    • /
    • 1989
  • Autonomous mobile robot Yamabico and his newly developed ultrasonic range finding module(URF) are described. Yamabico is a self-contained autonomous robot for in-door environment. It has a modularized architecture, which consists of master module, ultrasonic range finding module, locomotion module, voice synthesizer module and console. Newly developed ultrasonic range finding module has a 68000 processor and Dual-port memory for communication. It controls the ultrasonic transmitters and receivers and calculate the range distances for 12-direction, simultaneously within every 60 milliseconds.

  • PDF

Design and Implementation of a sensor node for out-door environmental monitoring (옥외 환경 모니터링을 위한 센서노드 설계 및 구현)

  • Son, Jae-Hyun;Cho, Yang-Haeng;Kim, Je-Hong;Joo, Young-Suk;So, Sun-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.77-82
    • /
    • 2007
  • In this paper, we described a design and implementation of a sensor node for environmental monitoring. The main focus of design for sensor nodes is to isolate MCU for treating sensors from the RF module for considering various communication environment. The second is to make the interface between MCU and varity of sensor. In addition, we choose a narrow band communication module, cc1020, for the admittance of Korea government comminication law. We also use a uC/OS-II as an operating system which is famous for 8bit MCUs. We showed that the communication performance is sufficient to use the communication module in a out-door environment through several experiments in that it is possible to transmit between loom distance through experiments in a mountain.

  • PDF

Optimum Design for Shock Absorber of Gullwing Door (걸윙도어 쇽업쇼버의 최적설계)

  • Jang, Y.J.;Lee, S.B.;Yim, H.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.188-191
    • /
    • 2005
  • In this paper, a design optimization technique is presented for determining the stiffness and the damping coefficient of the shock absorber that is used in the Gullwing door system of passenger car. The contact force between the shock absorber and stopper link, when the door is opened, is set up as objective function, and the stiffness and the damping coefficient are set up as design variables. ADAMS optimization module (SQP method) is applied in the design optimization process. This study shows that the stiffness and the damping coefficient of the shock absorber can be effectively determined in initial design stage of the Gullwing door.

  • PDF

Door-Lock System to Detect and Transmit in Real Time according to External Shock Sensitivity (외부 충격 감도에 따른 실시간으로 탐지하고 전송하는 Door-Lock 시스템)

  • Jeon, Byung-Jin;Han, Kun-Hee;Shin, Seung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.9-16
    • /
    • 2018
  • The purpose of this study is to prevent the malicious user from breaking the door-lock due to physical impact. If it matches the analog displacement value set in the door-lock system, it protects the body and property by transmitting damage information in real time to the manager smart phone. The research suggests a system that transmits damage information in real time to registered users when door-lock is damaged by physical impact. Then compare the impact information sensed by the door lock with the data of the sensitivity control unit. In the web server of the proposed system, after impact information transmitted from Door-Lock is stored in the DB, if the impact information is larger than the shock detection transmission reference value stored in the DB, it is transmitted to the administrator in real time by SMS module so that illegal access information.

Improvement Research of BLE-based System for Monitoring the cause of Breakdown of Automatic Doors (자동문의 고장원인을 모니터링하기 위한 BLE 기반의 시스템 개선연구)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.93-102
    • /
    • 2017
  • Recently increasing usage of smartphones makes the Internet of Things (IoT) a leading technology that can collect and share data through sensor networks and wireless communication such as low-power Bluetooth (BLE). BLE-based application can provide operators more precise information on Automatic Door system by remotely diagnosing the system faults through wireless sensor networks and sensors around the Automatic Door. In this paper, a smart device with extended BLE module is implemented which can monitor and Control the system states and faults remotely without on-site diagnostic. while maintaining system integrity so that increase efficiency of time and costs for system management. We can use the results of this research as a basis in evaluating reliability of data between devices, extending communication module in Controller of obsolete Door systems, and establishing centralized monitoring systems in near future with multi-channel Door Controls.

System Design for Access to Subway Vent based Bluetooth Smart Door-Lock (지하철 환기구 출입관리를 위한 블루투스 스마트 도어락 시스템)

  • Kim, Tae-Yong;Lee, Dae-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.63-65
    • /
    • 2016
  • In this paper, smart door-lock system to access public facilities will be proposed. An existed door-lock system using physical door-lock, NFC Tag, and RFID could be replaced by our proposed system. Automatic access control management system with security authentication module enables the worker to access public facilities efficiently.

  • PDF

Design of Heavy Weight Door Hinge for Built-in Appliances (빌트인 가전기기용 고 중량 도어힌지의 설계에 관한 연구)

  • Choi, Seong-Dae;Byn, Yong-Kun;Kim, Gi-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.41-47
    • /
    • 2021
  • In this study, the hinges of heavy weight doors were designed and analyzed in line with the trend that built-in appliances are becoming larger and the weight of doors is also increasing. The main specification of the heavy weight door hinge is to allow the deflection at the end of the door to be less than 2 mm when opening and closing, including the automatic closing, slow closing, and closing force control functions. The structural analysis of the design mechanism, component design, and methods for improving the deflection are as follows: 1) Mechanism of the automatic closing function should sense automatically using the spring compression force at a specific angle by the contact between the cam and the cam module roller. 2) Through structural analysis, the maximum stress of the door was found in the link pin hole connected to the pin at each link. 3) Consequently, the pin holder was designed and applied, with little variance, but up to 93% of the specification limit.

Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate (스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구)

  • Kim, Min-Jae;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.59-64
    • /
    • 2016
  • The PSD (Platform Screen Door System) has been installed to enhance the passengers' safety. A total of 592 stations operate the PSD system, which is almost 71.8% of all stations in South Korea. This study compared the opening rate between the PSD and train door, and calculated the exact amount of passengers at peak time. In addition, the evacuation time was simulated by Pathfinder 2015 with the exact input data. Some of the high density stations have extremely high dangerous points about the passengers' evacuation at some situations by the PSD door opening rate. In particular, due to the interference of a fixed door, when it stops at 7 m less than the regular position, its opening rate becomes less than half of the normal state. To solve this problem, it should be made possible to open the fixed door by changing it to an emergency door or improving the PSD module system.

Visible Light Identification System for Smart Door Lock Application with Small Area Outdoor Interface

  • Song, Seok-Jeong;Nam, Hyoungsik
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.90-94
    • /
    • 2017
  • Visible light identification (VLID) is a user identification system for a door lock application using smartphone that adopts visible light communication (VLC) technology with the objective of high security, small form factor, and cost effectiveness. The user is verified by the identification application program of a smartphone via fingerprint recognition or password entry. If the authentication succeeds, the corresponding encoded visible light signals are transmitted by a light emitting diode (LED) camera flash. Then, only a small size and low cost photodiode as an outdoor interface converts the light signal to the digital data along with a comparator, and runs the authentication process, and releases the lock. VLID can utilize powerful state-of-the-art hardware and software of smartphones. Furthermore, the door lock system is allowed to be easily upgraded with advanced technologies without its modification and replacement. It can be upgraded by just update the software of smartphone application or replacing the smartphone with the latest one. Additionally, wireless connection between a smartphone and a smart home hub is established automatically via Bluetooth for updating the password and controlling the home devices. In this paper, we demonstrate a prototype VLID door lock system that is built up with LEGO blocks, a photodiode, a comparator circuit, Bluetooth module, and FPGA board.