• 제목/요약/키워드: Domestic Refrigerator

검색결과 54건 처리시간 0.019초

Cervus nippon yesoensis (Japanese Yeso Deer) 사슴육에서의 색소 및 색소 안정성 (Color and Its Stability in Venison from Cervus nippon yesoensis(Japanese Yeso Deer))

  • M. Sekikawa;K. H. Han;K. Shimada;M. Fukushima;T. Ishikawa;C. H. Lee;M. Mikami
    • 한국축산식품학회지
    • /
    • 제23권4호
    • /
    • pp.309-314
    • /
    • 2003
  • Color and its stability in venison, longissumus dorsi (LD) and quadriceps femoris (QF) muscles, from 8 wild Cervus nippon yesoensis (Japanese Yeso Deer) were investigated by means of the CIE L$^{*}a{*}b{*}$ measurement and autoxidation rate recorded using partially purified myoglobin. It was observed a common feature of the change of three mean values($L^{*}$, $a^{*}$ and $b^{*}$) in both LD and QF that mean value increased at 1 or 2 day post-mortem and then decreased during storage. The differences between 1 and 7 days was the largest in $a^{*}$ value than those in $L^{*}$ and $b^{*}$ values. The mean differences among storage days were only significant in $a^{*}$ except for $b^{*}$ of LD. It was same tendency that the mean difference of CIE $L^{*}$, $a^{*}$ and $b^{*}$ values during refrigerator storage was larger in $a^{*}$ than both in $L^{*}$ and $b^{*}$ reported in beef(Sekikawa et al., 1995) and venison(Stevenson et al., 1989) during storage. The smaller $a^{*}$ value was indicated that bright red of meat changed to dull red, brown red causing met-Mb formation. To compare of color stability with respects to the Mb autoxidation rate, we measured this rate of deer and horse muscles, because horse Mb was considered to have the fastest autoxidation rate among domestic animals, and we used crude Mb and pH 6.0, which might be reflected to the intact meat. Mean value of the autoxidation rate measured in this study in deer was 0.037 and that was 0.026 in horse(sigma). Although there was no significant mean difference and were different Mb purity between deer(A409/A 280 nm = 4.0) and horse(5.6), in generally Mb purity was the higher and the faster autoxidation rate, but this rate in deer was faster than in horse. These results might indicate that venison meat discolors at faster rate compared with beef.

국내 전기전자 제품에 함유된 신규 RoHS II 물질 검출 사례 연구 (Case Study on Determination of the Level of New RoHS II Substances in Domestic Electronic and Electrical Equipments)

  • 송문환;손승환;조영달;최은경
    • 청정기술
    • /
    • 제17권2호
    • /
    • pp.124-133
    • /
    • 2011
  • 2006년 시행되어 온 RoHS 규제에 유해물질을 추가하여 더 강화된 RoHS II의 공표에 대비하여 본 연구에서는 RoHS II의 최우선 규제 물질이면서 2010년 발표된 REACH SVHC 후보목록에도 포함된 물질인 Hexabromocyclododecane (HBCDD) 및 3종 프탈레이트, Dibutyl phthalate (DBP), Butyl benzyl phthalate (BBP), Diethylhexyl phthalate (DEHP)의 국내 전기 전자제품내의 함유 여부를 사전 검토해보려는 목적으로 사례 연구를 진행하였다. 이에 고분자 소재로 구성된 세탁기, 냉장고, 혹은 전자렌지의 부품 20개를 12개 전기전자 부품 생산회사로부터 수거하여 4종 규제 물질을 기체크로마토그래피 질량분석법으로 분석하여 그 함유량을 측정한 결과 Nitrile Butadine Rubber (NBR), Polypropylene (PP), Polybutylene Terephthalate (PBT), Ethylene Propylene Rubber (EPDM), Polyvinyl Chloride (PVC) 등의 소재로 된 부품 중 HBCDD는 NBR 소재로 된 3종 부품에서 42~381 mg/kg 범위로 검출되어 규제값 0.1 wt% (1,000 mg/kg)보다는 적지만 주의를 요한다. DBP 및 BBP는 20개 부품모두에서 검출되지 않고 있어 이 두 물질은 전지전자 제품용 플라스틱 소재에서 넓게 사용되지 않고 있을 가능성을 시사하고 있다. 그러나 DEHP는 40~59,400 mg/kg 범위로 NBR, PP, PBT, EPDM 및 PVC로 이루어진 부품에서 모두 검출되어 광범위하게 사용되고 있음을 알 수 있었고 특히 NBR 및 PVC로 이루어진 8개 부품에서 예상 규제치인 0.1 wt% (1,000 mg/kg)을 훨씬 능가한 0.45~5.94 w%로 검출되고 있어 이에 대한 대비가 필요함을 알 수 있었다. 추가로 REACH SVHC (고위험성 물질)에 속하는 Diarsenic pentaoxide, Diarsenic trioxide, Lead hydrogen arsenate, Triethyl arsenate의 4종 물질의 함유 여부를 ICP에 의한 비소(Arsenic) 분석으로 스크리닝해 본 결과 NBR, PBT 소재의 4개 부품에서 15~700 mg/kg으로 검출되었고 이 중 PBT소재의 부품인 Thermistor에서는 규제되는 비소화합물이 규제값(0.1 wt%, 1,000 mg/kg)을 초과할 가능성이 매우 높다.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

국내 주요 5성급 호텔의 위생실태 조사와 ATP 결과의 상관분석 평가 연구 (Correlation Analysis of Inspection Results and ATP Bioluminescence Assay for Verification of Hygiene Status at 5 Star Hotels in Korea)

  • 김보람;이정아;하상도
    • 한국식품위생안전성학회지
    • /
    • 제36권1호
    • /
    • pp.42-50
    • /
    • 2021
  • 외식산업의 급속한 성장과 함께 호텔을 비롯한 외식업체에서는 식품안전 요구 및 위생에 대한 중요성 이 증가하고 있다. 이에 현장에서 위생상태를 판단할 수 있는 신속하고 실용적인 모니터링기법이 요구된다. 본 연구는 국내5성급 호텔 5군데를 대상으로 개인위생(작업자의 손), 조리기구(칼, 도마, 식품보관용기, 슬라이스 머신 칼날, 제빙기 스쿱), 시설·설비(냉장고 손잡이, 작업대, 싱크대), 고객 접점항목(뷔페용 집게)에 대한 위생관리 실태를 조사하였고 그에 대한 검증법인 ATP 값의 상관관계를 도출하고자 하였다. 5개 호텔의 위생관리 실태조사 결과, 다른 검사 항목보다 상대적으로 조리기구 및 개인위생 결과가 비교적 위생적으로 관리되고 있었으며(조리기구 92.2%, 개인위생 91.4%, 시설·설비 76.19%, 고객 접점항목 88.6%)으로 시설·설비는 비교적 미흡한 것으로 나타났다. ATP검사 결과, 조리 기구(51±45 RLU/25 ㎠)는 시설·설비(167±123 RLU/25 ㎠)보다 비교적 위생적으로 잘 관리되었다. 위생실태 조사 결과 점수와 ATP 값의 상관성 분석을 실시한 결과, 각 호텔 별 작업자 손, 조리기구, 시설·설비의 대부분 음의 상관관계를 가지며 높은 상관성(-0.64 - -0.89)을 보였다. 또한 이번 연구에서 각 검사 항목의 평소 상태의 ATP 값(1020±1254 RLU/25 ㎠)에 비해 세척 후 ATP 값(92±67 RLU/25 ㎠)이 현저히 감소되어 세척의 유효성을 확인하는 도구로 적합성을 확인할 수 있었다. 호텔을 비롯한 외식업체에서 수행하는 주관적인 위생실태조사와 ATP 검사법을 병행한다면, 실시간으로 보이지 않는 오염물질의 객관적인 수치화를 통해 식품사고 발생을 예방하기 위한 효과적인 모니터링 방법이 될 것으로 사료된다.