• 제목/요약/키워드: Domain wall

검색결과 387건 처리시간 0.033초

시간-주파수 기법을 이용한 배관 감육 감시 방법 (Monitoring Pipe Thinning Using Time-frequency Analysis)

  • 손창호;박진호;윤두병;정의필;최영철
    • 한국소음진동공학회논문집
    • /
    • 제16권12호
    • /
    • pp.1224-1230
    • /
    • 2006
  • Pipe thinning is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. In this paper, we proposed the method for monitoring pipe thinning. Our basic idea come from that a group velocity of impact wave is different as wall thickness. If the group velocity is measured, wall thickness can be estimated. To obtain the group velocity, time -frequency analysis is used. This is because an arrival time difference can be measured easily in time-frequency domain rather than time domain. To test the performance of this technique, experiments have been performed for a plate and U type pipe. Results show that the proposed technique is quite powerful in the monitoring pipe thinning.

3차 B-spline 함수를 이용한 열전도 및 유체문제의 해석 (Analysis for computing heat conduction and fluid problems using cubic B-spline function)

  • 김은필
    • 한국전산유체공학회지
    • /
    • 제3권2호
    • /
    • pp.1-8
    • /
    • 1998
  • We make use of cubic B-spline interpolation function in two cases: heat conduction and fluid flow problems. Cubic B-spline test function is employed because it is superior to approximation of linear and non-linear problems. We investigated the accuracy of the numerical formulation and focused on the position of the breakpoints within the computational domain. When the domain is divided by partitions of equal space, the results show poor accuracy. For the case of a heat conduction problem this partition can not reflect the temperature gradient which is rapidly changed near the wall. To correct the problem, we have more grid points near the wall or the region which has a rapid change of variables. When we applied the unequally spaced breakpoints, the results show high accuracy. Based on the comparison of the linear problem, we extended to the highly non-linear fluid flow problems.

  • PDF

스파터법에 의한 Co-계 비정질박막의 제작과 자기특성 (Preparation and Magnetic Properties of Co-system Amorphous Thin Film by the Sputter method)

  • 임재근;문현욱;서강수;신용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.190-191
    • /
    • 1994
  • In this paper, We study on the fabrication of amorphous this film of zeromagnetostriction material and the magnetic properties. This films are fabricated by using sputtering method with input power of 400∼607[W], Ar gas pressure of 3∼ 9[mTorr] and target composition of Fe$\sub$4.7/ Co$\sub$74.3/Si$_2$B$\sub$19/. Sample this films with diameter of 14[mm ] and thickness of 27-30[$\mu\textrm{m}$] were obtained through experiments. When we analyzed the magnetic properties before and after annealing with sample thin films, we confirmed that magnetic domain wall amorphous thin films consisted for Neel magnetic domain wall with the width of about 1[$\mu\textrm{m}$].

Current-Driven Domain-Wall Depinning in Pt/CoFe/Pt Nanowires with Perpendicular Magnetic Anisotropy

  • Kim, Kab-Jin;Lee, Jae-Chul;Choe, Sug-Bong
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.101-103
    • /
    • 2009
  • The spin transfer torque efficiency was determined experimentally by observing the current-driven domainwall depinning of Pt/CoFe/Pt nanowires with perpendicular magnetic anisotropy. The depinning time was exponentially proportional to the applied magnetic field, and was well explained by the Neel-Brown formula. The depinning time and threshold magnetic field were varied considerably by injecting current into the nanowire. The spin transfer torque efficiency was estimated to be $(7.2{\pm}0.9){\times}10^{-15}Tm^2$/A from the linear dependence of the threshold current density with respect to the applied magnetic field.

CHARACTERIZATION OF MAGNETIZATION BEHAVIOR IN Co/Pd PERPENDICULAR ANISOTROPIC MULTILAYERS

  • Oh, Hoon-Sang;Joo, Seung-Ki
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.655-658
    • /
    • 1995
  • Magnetization behavior of sputter-deposited Co/Pd multilayers were characterized, and it has been found that even when the multilayers are sputtered at low pressure (10 mTorr), the coercivity of the multilayers can be increased to large extent without noticeable change of saturation magnetization by increasing the deposition pressure of Pd underlayer. It turned out that the surface topology of Pd underlayer gets rough as deposition pressure increases, which consequently affects the magnetization reversal mode of Co/Pd multilayers from domain wall motion to magnetic spin rotation. The enhancement of coercivity is attributed to the domain wall pinning effect which is comected with the surface roughness of Pd underlayer on which Co/Pd multilayers grow.

  • PDF

조화용융성조성을 가진 $LiNbO_3$ 단결성의 미소결함 (Micro-defects in $LiNbO_3$ single crystals with congruent melting composition)

  • 김현기;권달회;이선우;심광보;오근호
    • 한국결정성장학회지
    • /
    • 제9권3호
    • /
    • pp.267-272
    • /
    • 1999
  • Czochralski법으로 성장시킨 조화용융조성(48.6 mol%$LiNbO_3$)의 undoped 및 MgO-doped $LiNbO_3$ 단결정 내의 미소결함을 광학현미경 및 주사/투과 전자현미경을 이용하여 정밀분석하였다. Dopant 첨가 및 성장된 부위(g)에 따른 분역구조의 변화와 결함밀도를 측정함으로써 결함양상을 분석하고 최적 결정성장조건과의 상관관계를 고찰하였다. 강자성 분역벽 주변의 높은 결함밀도는 이 근처가 응력이 집중된 영역임을 반영하고, 특히 한쪽 방향의 분역벽에만 결함이 밀집된 결함구조를 가지고 있음을 확인하였다.

  • PDF

한국 현대건축의 기술역사에 관한 연구 (A Study on the History of Technology in Korean Modern Architecture)

  • 정인하;김진
    • 건축역사연구
    • /
    • 제9권3호
    • /
    • pp.51-69
    • /
    • 2000
  • This study tries to analyze the development of architectural technologies appeared in several tall buildings and large spatial structures from 1955 to 1999 in Korea. We suppose that these buildings represent the development of technology in Korean modern architecture. By the detailed analysis of these buildings, we can arrive at a conclusion as such; During the years 1955-1999, there existed a great changement in the eighties. We can find this fact very well in the domain of structural system and curtain wall system. In large spatial structures, the structural-system of shell and steel truss dome was replaced by that of space frame, space truss and cable truss with membrane. In tall building, the structural system of rigid frame and shear wall was replaced by tubular system, core and outrigger system. Korean architects introduced the aluminum curtain wall in the sixties, but its low technological level caused many problems in reality. Therefore, precast concrete curtain wall appeared from seventies as the main method for an outer wall in tall building. With the augmentation of height after 1980, PC curtain wall was replaced by the aluminum curtain wall of unit type and structural glass wall system. These systems help to stress the transparency in a tall building.

  • PDF

자기광학현미경으로부터 관찰한 자구모양의 픽셀값 연산을 이용한 자벽선 결정방법 (Decision Method of Magnetic Domain Walls Using Pixel Value Operation in the Magnetic Domain Image Observed by Kerr Microscopy)

  • 김영학
    • 한국자기학회지
    • /
    • 제27권1호
    • /
    • pp.35-40
    • /
    • 2017
  • 기존의 광학현미경을 분해 하여 Kerr 현미경을 구성한 다음, 180도 자벽을 가지는 극박 3 %Si-Fe에 대해 자구모양을 관찰하였다. CCD 카메라로 취득한 한 단 한 장의 디지털 자구모양으로부터 자구영역의 경계선을 고가의 고속 영상처리장치 없이 결정하였다. 자구모양의 경계선 결정 방법은 디지털 자구모양의 픽셀값을 감산, 적분, 최소자승법의 연산을 이용하는 것이다. 이 방법은 많은 디지털 이미지를 연속적으로 취득하여 다중 합산하는 종래의 방식보다는 비용이 적게 든다. 이 연구 결과로부터 3개의 경계선과 0.085[T]의 자속밀도가 구해져 시편의 중심부와 같이 $180^{\circ}$ 자벽 만이 형성되는 영역이라면 이 방법을 적용할 수 있다.

Expression and Biochemical Characterization of the Periplasmic Domain of Bacterial Outer Membrane Porin TdeA

  • Kim, Seul-Ki;Yum, Soo-Hwan;Jo, Wol-Soon;Lee, Bok-Luel;Jeong, Min-Ho;Ha, Nam-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권5호
    • /
    • pp.845-851
    • /
    • 2008
  • TolC is an outer membrane porin protein and an essential component of drug efflux and type-I secretion systems in Gram-negative bacteria. TolC comprises a periplasmic $\alpha$-helical barrel domain and a membrane-embedded $\beta$-barrel domain. TdeA, a functional and structural homolog of TolC, is required for toxin and drug export in the pathogenic oral bacterium Actinobacillus actinomycetemcomitans. Here, we report the expression of the periplasmic domain of TdeA as a soluble protein by substitution of the membrane-embedded domain with short linkers, which enabled us to purify the protein in the absence of detergent. We confirmed the structural integrity of the TdeA periplasmic domain by size-exclusion chromatography, circular dichroism spectroscopy, and electron microscopy, which together showed that the periplasmic domain of the TolC protein family fold correctly on its own. We further demonstrated that the periplasmic domain of TdeA interacts with peptidoglycans of the bacterial cell wall, which supports the idea that completely folded TolC family proteins traverse the peptidoglycan layer to interact with inner membrane transporters.