Dog bone shaped specimen testing method to evaluate tensile strength of rock materials

  • Komurlu, Eren;Kesimal, Ayhan;Demir, Aysegul Durmus
    • Geomechanics and Engineering
    • /
    • 제12권6호
    • /
    • pp.883-898
    • /
    • 2017
  • To eliminate the holding and gluing problems making the direct tensile strength test hard to be applied, a new method of testing specimens prepared using lathe machine to make the dog bone shape is assessed whether it could be applied to determine accurate direct tensile strength values of rock materials. A series of numerical modelling analyses was performed using finite element method to investigate the effect of different specimen and steel holder geometries. In addition to numerical modelling study, a series of direct tensile strength tests was performed on three different groups of rock materials and a rock-like cemented material to compare the results with those obtained from the finite element analyses. A proper physical property of the lathed specimens was suggested and ideal failure of the dog bone shaped specimens was determined according to the results obtained from this study.

열간압연시 폭퍼짐 보상을 통한 폭정밀도 개선연구 (Precise width control through the width spread compensation in hot strip mill)

  • 천명식;이준정;문영훈
    • 소성∙가공
    • /
    • 제8권2호
    • /
    • pp.200-207
    • /
    • 1999
  • To increase dimensional accuracy of strip width, model to compensate width spread during roughing mill has been developed. To measure the amount of width spread during the production rolling more precisely, special roughing rolling procedures for the horizontal rolling and dog-bone rolling were designed in the actual production mill. From the operational data analysis, it is known that the prime factors influencing on the width spread were strip width, strip thickness, edging amount, number of pass and type of edger roll etc., Based upon the statistical analysis of rolling data, new models which can predict width spread during horizontal rolling and dog-bone rolling were developed and tested on the actual processing conditions for the reliability. The application test showed that newly developed model gave fairly accurate predictions on the width spread during roughing passes.

  • PDF

조압연 공정의 판 폭 퍼짐 예측 모델 - Part I : 도그 본 형상에 적용 (A New Model for Predicting Width Spread in a Roughing Mill - Part I: Application to Dog-bone Shaped Inlet Cross)

  • 이동훈;이경보;황상무
    • 소성∙가공
    • /
    • 제23권3호
    • /
    • pp.139-144
    • /
    • 2014
  • In the current study, we present a new model for predicting width spread of a slab with a dog-bone shaped cross section during rolling in the roughing train of a hot strip mill. The approach is based on the extremum principle for a rigid plastic material and a three dimensional admissible velocity field. The upper bound theorem is used for calculating the width spread of the slab. The prediction accuracy of the proposed model is examined through comparison with the predictions from 3-D finite element (FE) process simulations.

Hemisection and Endodontic Treatment of First Molar Tooth and Mandibular Fracture Repair in a Dog

  • Kim, Gyu-min;Kim, Jury;Bae, Hyeon-a;Kim, Nam-soo;Ji, Dong-Beom
    • 한국임상수의학회지
    • /
    • 제36권2호
    • /
    • pp.106-108
    • /
    • 2019
  • This clinical report describes hemisection and endodontic treatment of first molar tooth and mandible fracture repair in a dog. A 10 years old spayed female shih-tzu was diagnosed as left mandibular fracture by oral examination and dental radiography. First, partial odontectomy of mesial root of mandibular first molar placed in fracture line was performed, and then endodontic treatment of distal root and bone graft in extraction site was performed. Thereafter the fracture region was fixed with interdental wiring and acryl resin splint. Mandibular fracture site was healed without any complications, observed for 19 weeks follow-up period. Upon this result, this case is proving that fractured mandible can be treated successfully with hemisection followed by bone graft, interdental wiring and acryl resin splint to preserve the remaining tooth for mastication rather than tooth extraction.

말티즈 견의 두개골에서 발생한 다엽성 종양 (Multilobular Tumor of Skull in a Maltese Dog)

  • 양철호;강민희;김승곤
    • 한국임상수의학회지
    • /
    • 제33권1호
    • /
    • pp.48-50
    • /
    • 2016
  • A 10-year-old spayed female Maltese dog weighting 3.4 kg was referred with growing firm mass at the parietal bone region from 2 weeks ago. A firm, partially calcified mass ($1.9cm{\times}4.4cm$) was palpated in the region of the frontal and parietal skulls but had no neurologic signs. Computed tomography (CT) characteristics of mass were round to oval shape, fine granular appearance, and well defined margins. Mass involving the calvarial bones had invasion into the cranial vault with a significant intracranial portion. Histologically, the tumor was characterized by the presence of multiple lobules containing osteoid or cartilage in the center that were separated by anastomosing fibrous septae. This is case report described the clinical and histopathological features of multilobular tumor of skull in a Maltese dog.

교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구 (The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant)

  • 정규림;이성자
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.173-185
    • /
    • 2001
  • 본 연구는 경희대학교 치과대학 교정과와 Biosstech$^{\circledR)$이 개발한 교정용 골유착성 티타니움 임프란트를 이용하여 임프란트 매식 후 가해지는 교정력이 임프란트의 골유착에 미치는 영향과 임프란트 제거 후 손상된 치조골의 치유를 알아보기 위해 시행되었다. acid-etched type, sand-blasted type, sand-blasted & acid-etched type, 3종류의 교정용 임프란트 24개를 2마리 실험 동물의 구강 내에 식립하였다. dog1의 상하악 좌측에 식립한 6개 임프란트에는 식립 후 교정력을 주지 않았고, 우측에 식립한 6개 임프란트에는 식립 즉시 200-300gm의 교정력을 가하였다. dog2에서는 임프란트 식립후 4주의 치유기간을 기다린 후, 골 내에 고정되어 있는 모든 임프란트에 4주 동안 200-300gm의 교정력을 가하였다. 4주, 8주의 관찰 기간이 지난 후 실험 동물을 각각 희생시켜 임프란트와 주위 조직을 포함하는 비탈회 표본을 제작하여 광학 현미경하에서 검경하였다. 이 실험을 통해 다음과 같은 결과를 얻었다. 1. 골내 고정에 성공한 임프란트들의 식립 4주 후 조직 소견에서, 식립 즉시 교정력을 가한 임프란트와 교정력을 가하지 않은 임프란트 사이에 조직학적 차이가 없었다. 두 군 모두에서 미성숙 소주골이 임프란트 식립시 손상된 부위로 생성되고 있었으며 부분적인 골유착이 보였다. 2. 임프란트 식립 부위의 골손상이 완전히 치유되기 전에 가해진 교정력은 골유착의 진행을 방해하지 않았다. 4주의 치유기간 후 4주간 교정력을 가한 임프란트의 조직소견에서 골조직과 임프란트 계면 사이의 접촉은 더 넓은 부위로 진행되었고 나사골을 채우고 있는 신생골은 기저골의 구조와 형태를 닮은 층판골로 성숙되어 있었다. 3. 식립 후 임프란트 주위 연조직 염증이 심했던 임프란트는 대부분 탈락되거나 동요가 있었으며, 실험 동물 희생시 동요가 있었던 임프란트의 조직 소견에서 임프란트 주위는 연조직으로 둘러 쌓여 골조직과 분리되어 있었다. 4. 골내 고정에 실패한 임프란트의 식립 부위에서는 임프란트 제거 2주 후 염증 소견없이 왕성한 골형성을 나타내는 조직학적 소견이 관찰되었다.

  • PDF

개에서 3단계 골스캔을 이용한 골병변의 진단 (Detection of Orthopedic Disease Using Three Phase Radionuclide Bone Scan in the Dog)

  • 강성수;최석화
    • 한국임상수의학회지
    • /
    • 제19권1호
    • /
    • pp.103-106
    • /
    • 2002
  • Specific diagnosis of orthopedic disease can be diffcult in canine practice. Failure to detect the clinical signs of a disorder during physical examination of dogs with acute or chronic lameness is the most common reason for failure to make specific diagnosis. A 6-month-old, female doberman with history of swelling and non-weight-bearing lameness in the left forelimb was referred to Beterinary Teaching Hospital of Chungbuk National University. Physical examination, plain radiography, and conventional three-phase radionuclide bone scan were performed in the patient. Based on the physical exam and radiography, this case was diagnosed as elbow strain and subluxation. Conventional three-phase bone scan detected soft tissue inflammation and osteochondral lesions of elbow joint, and revealed good agreement with clinical findings. Therefore, conventional three-phase bone scan was able to provide the precise information about inflammation of soft tissue and osteochondral lesions of joint.

즉시형과 지연형 치아 임플란트에서 Tc-99m-MDP의 Bone Uptake 평가 (Evaluation of Bone Uptake on Tc-99m-MDP in Immediate and Delayed Dental Implants)

  • 김중현;김명환;이원국;이재영;강성수;최석화
    • 한국임상수의학회지
    • /
    • 제20권2호
    • /
    • pp.207-211
    • /
    • 2003
  • This investigation aimed to determine the relative merit of osseointegration in immediate and delayed implantation in the dog mandible using radiography and bone scintigraphy. five adult mongrel dogs with a mean weight of 8.5 kg were used in this investigation. During the entire study period. all dogs were fed with a soft commercial diet and water ad libitum to minimize functional loading of the implant. Twenty titanium alloy systems 4 mm in diameter and 10 mm in length blasted with calcium phosphate were prepared for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, radiography and bone scintigraphy were conducted. Bone scans were obtained using a large field of view gamma camera equipped with a collimator about 3 hours after intravenous injection of Tc-99m-MDP to the dogs. All the dogs were evaluated weekly for inflammation, necrosis, and other of the bone or sort tissue. Significant macroscopic lesions were not detected. Radioisotope scintigraphy with Tc-99m-MDP hat proved to be a reliable method for measuring increased bone activity at specific skeleton tissue sites. In conclusion, osseointegration in peri-implant bone did not differ significantly between the immediate and delayed implant procedures during the experimental period. The immediate implant may be an alternative treatment of implant insertion in animals.

치조골신장 부위에 식립된 임프란트 주위의 골형성에 관한 연구 (A HISTOMORPHOMETRIC STUDY OF BONE FORMATION AROUND IMPLANTS PLACED AFTER VERTICAL ALVEOLAR DISTRACTION IN THE DOG MEDEL)

  • 박종오;류동목
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.312-321
    • /
    • 2007
  • Purpose: Distraction osteogenesis has been applied to the maxillofacial implantology and good experimental and clinical results have been reported. However, histologic studies of implants placement on distraction osteogenesis of atrophic alveolar ridges are scarce. In this study, we compare the bone formation between in the transport part and in the distraction part by histomorphometric analysis. Materials & methods: Three adult beagle dogs were served as experimental subjects. The 2 premolars and 1st molar were extracted on the Lt. side of mandible in each beagle dog. After one month later, osteotomy was performed and distraction device was adapted. Distraction was performed with gradual incremental separation of two bone pieces at a rate of 1.0mm per day for 5 days. During consolidation phase, new bone was formed in the distraction zone between the separated bone pieces. 5 weeks after distraction phase, 3 implants were placed in each beagle dog. The implants were inserted through transport part and distraction part and inferior basal bone. The animals were sacrificed at 2 weeks, 4 weeks, and 12 weeks after implant placement. BIC and BA of implants on distraction part and transport part were measured histomorphometrically. Results: BIC, BA increased after implant placement as time goes by passes and new bone formation was slightly higher in transport part than in distraction part at 2 weeks, 4 weeks after implant placement. At 12 weeks after implant placement, BIC, BA of were 74%, 61% in transport part and 77%, 59% in distraction part, therefore there were no difference in BIC and BA between transport part and distraction part at 12 weeks after implant placement.

3D-printing Bone Model for Surgical Planning of Corrective Osteotomy for Treatment of Medial Patellar Luxation in a Dog

  • Jeong, Bumsoo;Jung, Jaemin;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.385-388
    • /
    • 2016
  • A 2-year-old, castrated male Chihuahua dog was referred for revision surgery for reluxation of the patella following surgery for medial patellar luxation (MPL) of the left stifle joint. On general inspection, the patient showed bilateral hindlimb weight-bearing lameness. On physical examination, bilateral non-reducible MPL was detected through palpation. Radiographs revealed bone deformities of both hindlimbs. Computed tomography (CT) was applied for a three-dimensional (3D) printing bone model to establish an accurate surgical plan. The bone plate was pre-contoured over the 3D-printing bone model after execution of corrective osteotomy and sterilized prior to use in surgery. Corrective osteotomy was performed through a staged, bilateral procedure. The patient showed improvement of limb function following surgery without reluxation of the patella. The use of 3D-printing bone model for accurate surgical planning of corrective osteotomy appears to be effective in increasing the accuracy of surgery. That may lead to successful surgical outcomes.