Heat Flow Characteristics of Traditional Ondol (Gudle) by Numerical Analysis (수치해석을 통한 구들의 열 흐름 특성 연구)

  • Rhee, Shin-Ho;Rhee, Gwang-Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.1
    • /
    • pp.17-22
    • /
    • 2007
  • The heat flow characteristics of the Gudle (traditional Ondol) used a lot at farm houses have been performed with variations of Bunengki (Fireridge) by numerical analysis and field experiment. The Doedon-Gorae (Return-Firetunnel) Gudle is analyzed among the structure of Gudle. The distribution of heat flow in Gorse (Firetunnel) and the temperature distribution in floor of 3 Buneomgi (Fire ridge) was more uniform than that of 1 Buneomgi. The heat efficiency of 3 Buneomgi was higher than that of 1 Bunengki. That is, the 3 Bunengk is more efficient and more uniform temperature.