• Title/Summary/Keyword: Dl Water

Search Result 148, Processing Time 0.021 seconds

A Study on the Quality Control of the Radioimmunoassay Serum $T_3$(triiodothyronine) (혈청(血淸)$T_3$의 방사면역측정시(放射免疫測定時) 정도관리(精度管理)에 관(關)한 검토(檢討))

  • Kyong, Kwang-Hyon;Choi, Young-Sook
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.55-62
    • /
    • 1982
  • Measurement of triiodothyronine($T_3$) concentration is useful for the diagnosic and treatment of thyroid gland diseases. Fundermental studies of measurement of $T_3$ concentration by radioimmunoassay were performed and values determined by commercially available kit, Coat-A-Count, Diagnostic Products Corporation. The optimal utilization of the radioimmunoassay in measuring $T_3$ concentrations is dependant not only on high quality performance of the assay, but also on their appropriate application to the clinical situation. These are several aspects that must be considered in every individual case. These include factors such as accurate pippeting in reagent preparation in the assay and through decanting to remove all visible moisture after incubation steps and so forth. In attempt to assess quality control of the radioimmunoassay of serum $T_3$, serum pools with high, medium, low $T_3$ concentrations were assayed for each of 5 samples. The results obtained with this study were as follow: 1. The coefficient of variation(C. V.) for the standard curve ranged between $0.2{\sim}3.5%$. 2. It was necessary that both incubation time and temperature should correctly be maintained all the in the assay performance. 3. The precison with the $T_3$ RIA procedure was good. 4. The measured values of serially diluted serum $T_3$ concentration with Ong/dl standard solution was proportional to the predicted values. However dilution curve of distilled water was not strait. 5. Calculated $T_3$ values of patient serum in normal group was $107.8{\pm}25.90ng/dl$ in male patient and $127.29{\pm}24.08ng/dl$ in female patient.

  • PDF

Effect of the Plants Mixture and Garlic Composition on Serum Lipid Level of Hypercholesterolemic Rats (식물류 혼합물과 마늘의 복합 조성이 고콜레스테롤혈증 흰쥐의 혈청 지질에 미치는 영향)

  • Shin, Jung-Hye;Lee, Soo-Jung;Jung, Woo-Jae;Seo, Jong-Kwon;Sung, Nak-Ju
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.396-402
    • /
    • 2010
  • This study was designed to investigate the effects of 4 kinds of plant water extract mixture and garlic extract (PMC) administration on serum lipid metabolism in hypercholestrolemic rats. The normal group was administered a cholesterol free diet, the control group a 1% cholesterol diet, and each experimental group was given a diet of 1% cholesterol, 1% plant mixture and 0.3, 0.5, 0.7% garlic extract (PMC-I, PMC-II, PMC-III), respectively. Each diet was administered orally to SD-male rats for 4 weeks. Total cholesterol content decreased by about 20% with administration of PMC. Triglyceride content also decreased from 9.3 to 15.0% compared to the control group, and phospholipid was similar to triglyceride. There was no significant difference in HDL-cholesterol content between the control and experimental groups. LDL-cholesterol content of the normal group was 9.4 times lower than the control group and its content was significantly lower in the PMC-II ($68.45{\pm}12.83\;mg/dl$) and PMC-III ($66.35{\pm}5.18\;mg/dl$) groups than the PMC-I group. VLDL-cholesterol content of the PMC-II and III groups were similar to the normal group. Atherogenic index (AI) and cardiac risk factor (CRF) were significantly lower in the PMC group. Blood glucose content was the lowest in the PMC-II ($189.37{\pm}12.02\;mg/dl$) group among all groups tested. Total protein content was $9.56{\pm}0.87{\sim}10.05{\pm}2.69\;mg/dl$ in the PMC-I~III groups and was significantly higher than the normal group. CPT activity did not show a significant difference among the experimental groups, while COT activity was effective only in the PMC-I group. Serum TBARS content in the PMC-III group was lower than in the normal group. Serum antioxidant activity by DPPH radical scavenging was $83.75{\pm}2.32%$ in the PMC-III group, which was significantly higher than the control group.

Introduction of the Best Practices in the Pakistan Gulpur HEPP (파키스탄 Gulpur 수력발전 현장의 Best Practices 소개)

  • JANG, Ock Jae;HONG, Won Pyo;CHAE, Hee Moon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.216-217
    • /
    • 2022
  • Gulpur 수력발전 프로젝트는 전력난을 겪고 있는 파키스탄에 102 MW 규모의 수력발전소를 건설하여 30년 동안 운영 관리한 후 파키스탄 정부로 양도하는 IPP(Independent Power Producing) 형식의 투자사업이다. 남동발전과 DL E&C, 롯데건설이 Sponsor로서 출자한 자본금과, ADB, IFC, K-EXIM 등의 대주단로부터의 차입금을 재원으로 하여 소요 사업비를 조달하고 사업을 개발하였다. DL E&C와 롯데건설이 EPC(Engineering, Procurement, Construction)를 수행하였고, 이산이 Design consultant의 역할을 수행하였다. Gulpur 수력발전 프로젝트의 발전형식은 수로식(run-of-river)으로 201 m3/s의 발전유량과 102 MW의 발전 시설용량을 이용하여 연평균예상발전량은 398 GWh이다. 주요 구조물로는 설계 재현빈도 1년의 유수전환시설(가물막이댐 & 가배수터널)과 콘크리트 중력식댐(H 67 m, L 205 m), 도수터널(D 6.7 m, L 215 m, 2기), 옥외형 발전소 (H 51 m, W 60 m, L 38 m, Kaplan 2기)가 있으며, 2015년 10월 착공하여 2020년 3월 상업발전을 시작하였다. 본 프로젝트는 DL E&C의 첫 번째 EPC 해외수력발전 프로젝트이다. 따라서 프로젝트의 성공적 수행을 위한 경제적 설계, 시공의 효율성 및 안정성 확보 등을 위하여 많은 연구를 수행하는 과정에서 다양한 기술 개선을 이룰 수 있었다. 본고에서는 Gulpur 프로젝트를 통하여 도출된 성공 사례들을 소개 및 공유하고자 한다. 첫 번째로 콘크리트 중력식댐 시공을 위한 유수전환시설의 최적 설계빈도를 산정하였다. 일반적으로 유수전환시설의 규모는 설계기준에 제시된 설계 재현빈도를 이용하는데, 해외 설계기준에서는 10년, 국내 설계기준에서는 1~2년으로 다르게 제시되어 있는 문제점이 있다. 유수전환시설의 규모는 프로젝트의 경제성에 큰 영향을 미치기 때문에 최적 설계빈도의 결정이 필요하며, 위험도분석기법(Risk Analysis)과 기대화폐가치법(Expected Monetary Value)을 이용하여 유수전환시설의 최적 설계 재현빈도와 이에 영향을 미치는 인자를 분석하였다. 위험도는 몬테카를로 시뮬레이션으로 산정된 가물막이댐 파괴확률과 재현빈도를 이용하여 산정된 가물막이댐 월류확률을 고려하였으며, 비용 및 피해액으로는 유수전환시설의 공사비, 가물막이댐 파괴시의 재건설비용과 지체보상금, 가물막이댐 월류시의 복구비용을 고려하였다. 이에 대한 연구결과로, 유수전환시설의 사용기간과 월류시의 복구비용이 유수전환시설의 설계 재현기간 결정에 가장 큰 영향을 미치는 것으로 나타났고, 특히 월류시의 복구비용이 작을수록 낮은 설계 재현빈도를 선택하는 것이 타당한 것으로 나타났다. 예를 들어, 유수전환시설의 사용기간이 3 ~ 5년, 복구비용이 0.5 ~ 1.0 mil USD 이하인 조건에서 가물막이시설의 최적 설계빈도는 1년 ~ 2년인 것으로 나타났다. 또한, 유수전환시설의 사용기간은 본댐의 규모와 시공기간 등을 고려하여 결정되는 사항으로 설계자가 임의 조정할 수 없지만, 복구비용은 시공 관리자에 따라 결정되는 부분으로, 적극적 홍수 피해 저감 및 복구방안을 마련하는 것이 프로젝트의 경제성을 향상시킬 수 있다는 것을 알 수 있었다. 두 번째로 프로젝트의 경제성 향상, 홍수기 댐 시공시의 안전성 확보를 위하여 홍수 조기경보시스템(Early Warning System)을 개발 및 활용하였다. 수로식(Run-of-river) 수력발전댐은 대부분 산악지역에 위치하기 때문에 국지성 강우 및 급한 지형 경사로 인하여 돌발홍수(flash flood)의 발생 가능성이 높다. 따라서 시공 중 홍수(월류) 발생을 미리 감지하고 현장에 전파할 수 있는, 수로식(Run-of-river) 수력발전댐 현장을 위한 홍수 조기경보시스템이 필요하며, 이를 리스크 인식, 모니터링 및 경보, 전파 및 연락, 반응 능력 향상의 4가지 부분으로 나누어 구축하였다. 리스크 인식 부분에서는 가물막이댐 월류 발생 상황에 대한 위험도, 취약성, 리스크를 제시하였으며, 모니터링 및 경보 부분에서는 상류 측정수위에서 유도된 현장 예상수위와 실제 현장 측정 수위를 대상으로 경보홍수위와 위험홍수위로 나누어 관리하였다. 전파 및 연락 부분에서는 현장 시공 조직을 활용하여 홍수시를 대비한 비상연락체계도(Emergency communication flow chart)를 운영하였으며, 반응 능력 향상을 위해 비상연락체계도의 팀별 Action plan을 상세화 하였다. 세 번째로 현장의 지질특성과 50여 차례 발파시험으로 현장 고유의 발파진동감쇄곡선을 도출하였으며, 이를 통해 현장의 시공성과 콘크리트 품질 확보를 동시에 달성할 수 있는 방안을 제시하였다. 콘크리트댐 공사에서는 제한된 공기 내에 공사를 완료하기 위해 사면부 굴착과 콘크리트 타설이 동시에 수행될 수밖에 없는 문제점을 가지고 있다. 그러나 신규 콘크리트 타설면 근처에서 발파를 수행하는 경우 발파로 발생되는 탄성파가 일정 수준을 초과하게 되면, 콘크리트 양생에 영향을 주게 된다. 따라서 다수의 현장 발파시험을 통해 발파거리와 최대진동속도의 상관관계 즉, 발파진동감쇄곡선을 도출함으로써 현장의 발파진동특성을 도출할 수 있었다. 또한, 기존 연구 논문들을 통해 콘크리트 재령기간 별 안전진동속도를 선정하고, 해당 안전진동속도를 초과하지 않는 범위에서 콘크리트 타설면과 발파위치의 거리에 따라 1회 발파 가능한 장약량을 산정하여 적용하였다. 이와 같은 체계적인 접근을 통해 콘크리트 타설과 발파 작업 동시 수행에 대한 논란을 해소할 수 있었다.

  • PDF

Spray Charaeteristics and Exhaust Emission Tests far a Diesel Engine Using Emulsified Fuels (에멀젼 연료를 이용한 디젤엔진의 분무 및 배기특성 연구)

  • 서희준;오승묵;허환일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.60-68
    • /
    • 2002
  • Experiments have been conducted to investigate the effects of emulsified fuels on the spray characteristics and exhaust emissions in a diesel engine. Four different fuels were examined : diesel, emulsified fuels with water contents which were varied with 13, 15, and l7wt%. Characteristics of fuel spray were measured by an optical method, PLLIF(planar liquid laser induced fluorescence). Compared to diesel fuel, emulsified fuels which had relatively high kinematic viscosity showed smaller spray angle and longer spray tip penetration. The qualitative droplet distributions of emulsified fuels showed worse atomization process than that of diesel fuel. As the water contents were increased, PM and NOx could be reduced simultaneously. It was specially noted that the emulsified fuel with l7wt% water content was found to be the best in reducing rates, NOx 30% and PM 40%.

A Study on the Characteristics of NOx and another Emisson by Water Injection System for a Light-Duty Diesel Engine (물 분사 시스템에 의한 소형 디젤엔진의 NOx 및 그 외 배출물의 특성에 관한 연구)

  • Choi Jae-Sung;Nam Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.628-636
    • /
    • 2005
  • In this paper. the effects of a WI(Water Injection) in the intake pipe for a 4-cylinder Dl(Direct Injection) diesel engine are investigated experimentally, The WI system was controlled by the duty cycle from the intake manifold's temperature and MAF(Manifold Air Flow) First. effect of EGR on NOx reduction was investigated. Then WI system was applied to reduce NOx As the results. we can make the NOx map and visualize the NOx results by variation of engine speed and engine load It was known that effect of WI system on NOx reduction without the EGR was better than the with EGR base engine except of low load and speed condition.

The Nutritional Physiology of Red Rotting of Ginseng cause by Erwinia carotovora (인삼적부병원균의 영양생리학적 연구)

  • 유병서;이민웅;이지열;최혜정
    • Korean Journal of Microbiology
    • /
    • v.20 no.3
    • /
    • pp.119-124
    • /
    • 1982
  • As a basic study to elucidate nutritional physiology and composition of synthetic medium of red rotting bacteria, Erwinia carotovora, of ginseng, the effects of hydrogen ion concentration, various kinds of carbon sources, nitrogen source, micrometallic salts and it's concentration on the gorwth of the bacteria were investigated and the results were as follows. Optimal pH in the basal medium for the growth of the bacteria was 6.5. After incubation the pH in culture media was neutralized. Among the various kinds of carbon sources, sucrose, glucose mannitol, but organic acids were not utilized effectively as nutrients. After incubation the pH turned acidic. Alanine as organic nitrogen sources nad ammonium sulfate as inorganic nitrogen promoted the growth, but L-valine and sodium nitrite were the least effective. Ferric chloride 1.0mg/dl and ferrous sulfate 100mg/dl were the most effective as micrometallic sources. Control and boric acid were the least effective. New synthetic medium based on the above results was follows ; Alanine 1.0g, $KH_2PO_4\;1.0g, \;sucrose\;30.0g, \;MgSo_4{\cdot}7H_2O\;0.5g, \;FeCl_3{\cdot}6H_2O\;1.0mg\;thiamine\;200{\gamma}g$, and distilled water 1000ml, pH6.5.

  • PDF

LARGE EDDY SIMULATION OF VORTEXING FLOW IN THE MOLD WITH DC MAGNETIC FIELD

  • Zhongdong Qian;Yulin Wu
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.56-62
    • /
    • 2005
  • Large eddy simulation of vortexing flow of molten steel in the continuous casting mold with and without DC magnetic field was conducted. The influence of the position of magnetic field to the residence time and depth of the vortex was analyzed. The mechanism of the influence of magnetic field to the vortexing flow was found. The computational results show that the vortexing flow is the result of shearing of the two un-symmetric surface flows from the mold narrow faces when they meet adjacent to the SEN; the un-symmetric flow for turbulent vortex is caused by turbulent energy of the fluid and that for biased vortex is caused by biased flow and the turbulent energy of fluid; with the moving of the magnetic field from the centerline of the outlet of the SEN to the free surface, the surface velocity is decreased gradually and the depth of the turbulent vortex and the biased vortex is decreased, the residence time is increased with the magnetic field moves from DL=120mm to DL=60mm and then decreased; the turbulent vortex and the biased vortex can be eliminated when the magnetic field is located at the free surface.

Application of Radio Frequency Microwave Technique for Glucose Detection (포도당 검출을 위한 라디오 주파수 마이크로파의 적용)

  • Kim Tae-Woo;Park Byoung-Soo;Cho Dong-Uk;Han Khil-Sung;Cho Tae-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.4
    • /
    • pp.171-178
    • /
    • 2004
  • Radio frequency (RF) microwave can be used to predict glucose concentration in a sample. This paper presents preliminary results in determining the concentration by measuring relative permittivity in the solutions of distilled water, saline, human serum, and human blood containing glucose. It was shown that the microwave method has larger penetration depth of about 100times of NIR, than NIR technique in measuring glucose concentration for the tissue like a human muscle. The larger penetration depth of the method has advantages because it is more useful to detect glucose in a human body non-invasively. In the experiments, sensitivity for detecting glucose concentration in blood solutions was almost 57mg/dl at the frequency of approximately 5.8GHz.

  • PDF

Rust Fungus Diferentiation on Host Leaves (기주식물엽에 있어서 녹병균의 분화)

  • ;Rohringer R.
    • Korean Journal of Microbiology
    • /
    • v.13 no.1
    • /
    • pp.37-44
    • /
    • 1975
  • As a basic study to elucidate nutritional physiology and composition of synthetic medium of red rotting bacteria, Erwinia carotovora, of ginseng, the effects of hydrogen ion concentration, various kinds of carbon sources, nitrogen source, micrometallic salts and it's concentration on the gorwth of the bacteria were investigated and the results were as follows. Optimal pH in the basal medium for the growth of the bacteria was 6.5. After incubation the pH in culture media was neutralized. Among the various kinds of carbon sources, sucrose, glucose mannitol, but organic acids were not utilized effectively as nutrients. After incubation the pH turned acidic. Alanine as organic nitrogen sources nad ammonium sulfate as inorganic nitrogen promoted the growth, but L-valine and sodium nitrite were the least effective. Ferric chloride 1.0mg/dl and ferrous sulfate 100mg/dl were the most effective as micrometallic sources. Control and boric acid were the least effective. New synthetic medium based on the above results was follows ; Alanine 1.0g, $KH_2PO_4$ 1.0g, sucrose 30.0g, $MgSo_4$ $7H_2$O 0.5g, $FeCl_36H_2$O 1.0mg thiamine 200.gamma.g, and distilled water 1000ml, pH6.5.

  • PDF

The Effects of Fructose Polymer Levan on the Body Fat Accumulation and Serum Lipid Profiles of Korean Women (레반 Diet 섭취에 의한 한국 여성의 체지방 축적 억제와 혈중 지질의 개선 효과)

  • 강순아;장기효;이재철;장병일;임영애;송병춘
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.6
    • /
    • pp.986-992
    • /
    • 2003
  • This study was performed to investigate the effects of a levan diet on the body fat accumulation and serum lipid composition of 29 Korean women over a period of up to 12 weeks (n=13 for the control group, n=16 for the levan group). The subjects ate an uncooked diet (6 g) with 400$m\ell$ of tap water twice a day. The mean body weight and height measurements of the subjects (levan group) at the outset were 66.0$\pm$8.8kg and 156.7$\pm$5.3cm, respectively. The subjects showed a significant reduction in weight, body fat mass, anthropometric measurements and skinfold thickness during the experimental period. The waist hip ratio (WHR) was 0.88$\pm$0.03 at the outset, and fell to 0.82$\pm$0.05 after 4 weeks. The intake of levan was also influenced on the levels of serum Fe, leptin, lipoprotein lipase, HDL-cholesterol, LDL-cholesterol, and triglyceride. The serum glucose levels were within the normal range during the experimental period. The initial serum triglyceride level was 121mg/dl, but fell to 103mg/dl after 4 weeks of levan supplementation. The current study demonstrates that a levan diet is effective in controlling weight, body fat, HDL-cholesterol, LDL-cholesterol, and triglyceride levels.