• Title/Summary/Keyword: Division coefficient

Search Result 1,927, Processing Time 0.028 seconds

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

Development on the Questionnaire of Cold-Heat Pattern Identification Based on Usual Symptoms: Reliability and validation Study (평소 증상 기반 한열변증 설문지의 신뢰도 및 타당도 연구)

  • Bae, Kwang Ho;Jang, Eun Su;Park, Kihyun;Lee, Youngseop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.5
    • /
    • pp.341-346
    • /
    • 2018
  • The aims of this study were to evaluate the reliability and validity of the cold and heat pattern identification questionnaire (CHPIQ). From July 2015 to December 2015, 120 participants, university faculties, filled out CHPIQ by the way of self-reporting. Then two Korean medical doctors independently diagnosed them whether they belonged to cold pattern (CP) or not, and heat pattern (HP) or not. We evaluated the internal consistency using Cronbach's alpha coefficient, and the validity using the sensitivity and specificity through receiver operating characteristic-curve. The internal consistency (Cronbach's alpha coefficient) showed 0.754 (CP) and 0.753 (HP). The area under the curve was recorded with 0.884 (CP) and 0.786 (HP). The agreements between CHPIQ and experts were 82.8% (CP) and 72.9% (HP). The sensitivities showed 0.707 (CP) and 0.719 (HP), and the specificities were 0.935 (CP) and 0.736 (HP). This study suggests that CHPIQ is a reliable and valid instrument for estimating cold-heat pattern identification.

Calling song and phonotactic selectivity in the field cricket Teleogryllus emma (Orthoptera: Gryllidae)

  • Jang, Soo-Jin;An, Hyon-Gyong;Jang, Yi-Kweon
    • Journal of Ecology and Environment
    • /
    • v.33 no.4
    • /
    • pp.307-315
    • /
    • 2010
  • Males of the field cricket Teleogryllus emma produce calling songs that are attractive to receptive females. The calling songs of T. emma consist of two components, the long chirp that is composed of up to 12 single pulses, followed by a variable number of short chirps. Based on the analysis of coefficient of variation (CV), temporal characters of the long chirp were less variable than those of the short chirps in male calling songs. To test for phonotactic selectivity of females, we conducted a single-stimulus playback experiment in which five stimuli (standard, long chirp only, long chirp augmented, short chirps only, and short chirps augmented) were used. The standard stimulus included both long and short chirps whose characteristics were derived from the calling songs of field populations. Results of the playback experiment showed that female crickets oriented more frequently toward the stimuli that included the long chirp (standard, long chirp only, and long chirp augmented stimuli) than toward the stimuli lacking the long chirp (short chirps only and short chirps augmented stimuli), indicating that the long chirp in the calling songs was required to elicit positive phonotaxis in the female crickets. The result of CV analysis of the male calling songs and the findings of the female phonotaxis experiment suggested that the long chirp of calling songs may play a role in species recognition in T. emma.

A 4th order SC Bandpass ${\sigma}-{\Delta}$ Modulator of Novel Architecture with Control of the Intermediate Frequency (중간주파수 조절이 가능한 새로운 구조의 4차 SC Bandpass ${\sigma}-{\Delta}$ Modulator)

  • Kim, Jae-Bung;Kim, Kang-Jik;Cho, Seong-Ik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.31-35
    • /
    • 2009
  • In this paper, tunable 4th order SC(switched capacitor) bandpass ${\sigma}-{\Delta}$(Sigma-Delta) modulator with advanced architecture that can adjust the IF by two coefficient values is proposed for data conversion in the wireless communication. Its architecture can optionally adjust all the 4th order noise transfer function in comparison with the conventional architecture. In order to adjust the IF, the conventional architecture needs the four variable coefficients values, basic clocks and eight clocks. On the other hand, the proposed architecture can adjust the IF by two variable coefficient values and basic clocks only.

The Theoretical Study of the Measuring Thermal Diffusivity of Semi-Infinite Solid Using the Photothermal Displacement

  • Jeon, PiIsoo;Lee, Kwangjai;Yoo, Jaisuk;Park, Youngmoo;Lee, Jonghwa
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1712-1721
    • /
    • 2004
  • A method of measuring the thermal diffusivity of semi-infinite solid material at room temperature using photothermal displacement is proposed. In previous works, within the constant thickness of material, the thermal diffusivity was determined by the magnitude and phase of deformation gradient as the relative position between the pump and probe beams. In this study, however, a complete theoretical treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in semi-infinite solid materials. The influence of parameters, such as, radius and modulation frequency of the pump beam and the thermal diffusivity, was studied. We propose a simple analysis method based on the zero -crossing position of real part of deformation gradient and the minimum position of phase as the relative position between two beams. It is independent of parameters such as power of pump beam, absorption coefficient, reflectivity, Poisson's ratio, and thermal expansion coefficient.

The Sliding Wear Behavior of Inconel 600 Mated with SUS 304 (SUS 304에 대한 Inconel 600의 Sliding 마모거동)

  • Kim, Hun;Choi, Jong-Hyun;Kim, Jun-Ki;Park, Ki-Sung;Kim, Seung-Tae;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.841-845
    • /
    • 2001
  • The steam generator tubes of power plant damaged by sliding wear due to flow-induced motion of foreign object. Amount of wear have been predicted by Achard's wear equation until now. However, there are large error and low reliability, because this equation regards wear coefficient(k) as constant. The sliding wears tests have been performed at room temperature to examine parameters of wear (wear distance, contact stress). The steam generator tube material for wear test is used Inconel 600 and foreign object material is used 304 austenite stainless steel. The sliding wear tests show that the amount of wear is not linearly proportional to the wear distance(for 374 austenite stainless steel). According to experimental result, wear coefficient is not constant k but function k(s) of wear distance. The newly modified wear predictive equation V=k(s)F have small error and high reliability.

  • PDF

Morphometric Variation in Pine Wood Nematodes, Bursaphelenchus xylophilus and B. mucronatus, Isolated from Multiple Locations in South Korea

  • Moon, Yil-Sung;Son, Joung A;Jung, Chan Sik
    • The Plant Pathology Journal
    • /
    • v.29 no.3
    • /
    • pp.344-349
    • /
    • 2013
  • Intraspecific variation in morphometry of pine wood nematodes Bursaphelenchus xylophilus and B. mucronatus in relation to geographical locations in South Korea was investigated using morphometric characters (body length, a, b and c ratio, stylet length, and spicule length for a male nematode and V (%) value for a female nematode). B. xylophilus was isolated from Pinus thunbergii in Jinju (1998), Ulsan (2000), Yangsan (2000), Mokpo (2001) and Jeju (2004), and from P. densiflora in Gumi (2001). B. mucronatus was isolated from P. thunbergii in Jinju (1991) and from P. densiflora in Milyang (2001). The body length of male and female B. xylophilus had the highest coefficient of variability and showed significant differences among geographical locations. The V (%) value for female B. xylophilus showed the lowest coefficient of variability, changing little with geographical area and host plant. All morphometric characters in B. mucronatus except for stylet length and female body length showed no significant differences between locations or hosts, suggesting they may not be affected by geographical area or host plant.

An Experimental Study on Heat Transfer Performance of Fluidized Bed Heat Exchanger for Heat Recovery from Multi-Heat Sources (다중열원 열회수형 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2017
  • The heat transfer performance of a multi-heat-source fluidized bed heat exchanger was analyzed. The fluidized bed heat exchanger examined in this study can simultaneously recover the waste heat from gas, water vapor, and hot water. The effects of waste water flow rate, gas flow rate, and cooling water flow rate were examined to find their experimental correlations with the heat transfer coefficient. A computer program using the correlations was developed in this study to predict the thermal performance of the fluidized bed heat exchanger. The calculated heat transfer rates of gas, water vapor, waste water, and cooling water were compared with the measured values. It was found that the error of the calculated values was less than 12%.

Tribological Properties of Carbon Layers Produced by High Temperature Chlorination in Comparison with DLC Coating (DLC 코팅과 비교된 고온 염소처리에 의한 탄소 막의 Tribological 특성)

  • Choi, Hyun-Ju;Bae, Heung-Taek;Na, Byung-Chul;Lee, Jeon-Kook;Lim, Dae-Soon
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.7
    • /
    • pp.375-380
    • /
    • 2007
  • Tribological properties of carbon layers produced by high temperature chlorination of SiC ceramic and DLC (diamond-like carbon) coatings produced by ion plating method were investigated and compared. Carbon coatings were produced by exposure of ball and disc type SiC in chlorine and hydrogen gas mixtures at $1200^{\circ}C$. After treatment for 10 h, dense carbon films up to $180{\mu}m$ in thickness were formed. Tribological behavior of newly developed carbon films were compared with that of DLC films. Wear resistance and frictional coefficient of the surface modified ball and disc type SiC were significantly improved compared to an untreated SiC specimen, and also the modified carbon layer had better performance than DLC coatings. Therefore, in this study, the newly developed carbon films have several advantages over existing carbon coatings such as DLC coatings and showed superior tribological performances.

The Changes of Transfer film and friction Characteristics with the Relative Amounts of Raw Materials (자동차용 마찰재에서 각 원료의 상대량에 따른 전이막 형성 및 마찰특성의 변화)

  • Cho, Min-Hyung;Lee, Jae-Young;Kim, Dae-Hwan;Cheong, Geun-Joong;Choi, Chun-Rak;Jang, Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.271-280
    • /
    • 2001
  • An NAO friction material (low-steel type) containing 15 ingredients was investigated to study the role of transfer film on the friction characteristics. The friction material specimens with extra 100% of each ingredient were tested using a pad-on-disk type tribotester. A non-destructive method of measuring the transfer film was developed by considering the electric resistance of the transfer film. Results showed that solid lubricants and iron powder assisted transfer film formation on the rotor surface. Average friction coefficient was independent of transfer film thickness in this experiment. On the other hand, the thick transfer film on the rotor surface reduced the amplitude of friction oscillation under temperature conditions ( 250$^{\circ}C$) that transfer film forms.

  • PDF