• Title/Summary/Keyword: Diverging collimator

Search Result 4, Processing Time 0.014 seconds

Development of a diverging collimator for environmental radiation monitoring in the industrial fields

  • Dong-Hee Han;Seung-Jae Lee;Jang-Oh Kim ;Da-Eun Kwon;Hak-Jae Lee ;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4679-4683
    • /
    • 2022
  • Environmental radiation monitoring is required to protect from the effects of radiation in industrial fields such as nuclear power plant (NPP) monitoring, and various gamma camera systems are being developed. The purpose of this study is to optimize parameters of a diverging collimator composed of pure tungsten for compactness and lightness through Monte Carlo simulation. We conducted the performance evaluation based on spatial resolution and signal-to-noise ratio for point source and obtained gamma images and profiles. As a result, optimization was determined at a collimator height of 60.0 mm, a hole size of 1.5 mm, and a septal thickness of 1.0 mm. Also, the full-width-at-half-maximum was 3.5 mm and the signal-to-noise ratio was 53.5. This study proposes a compact 45° diverging collimator structure that can quickly and accurately identify the location of the source for radiation monitoring.

Design of Gamma Camera with Diverging Collimator for Spatial Resolution Improvement (공간분해능 향상을 위한 확산형 콜리메이터 기반의 감마카메라 설계)

  • Lee, Seung-Jae;Jang, Yeongill;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.661-666
    • /
    • 2019
  • Diverging collimators is used to obtain reduced images of an object, or to detect a wide filed-of-view (FOV) using a small gamma camera. In the gamma camera using the diverging collimators, the block scintillator, and the pixel scintillator array, gamma rays are obliquely incident on the scintillator surface when the source is located the periphery of the FOV. Therefore, the spatial resolution is reduced because it is obliquely detected in depth direction. In this study, we designed a novel system to improve the spatial resolution in the periphery of the FOV. Using a tapered crystal array to configure the scintillation pixels to coincide with the angle of the collimator's hole allows imaging to one scintillation pixel location, even if events occur to different depths. That is, even if is detected at various points in the diagonal direction, the gamma rays interact with one crystal pixel, so resolution does not degrade. The resolution of the block scintillator and the tapered crystal array was compared and evaluated through Geant4 Application for Tomographic Emission (GATE) simulation. The spatial resolution of the obtained image was 4.05 mm in the block scintillator and 2.97 mm in the tapered crystal array. There was a 26.67% spatial resolution improvement in the tapered crystal array compared to the block scintillation.

Effect of Scatter Media on Small Gamma Camera Imaging Characteristics (방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구)

  • Seo, Hyun-Kwan;Choi, Yong;Im, Ki-Chun; Woo, Sang-Geun;Lee, Jun-Soo;Song, Tae-Yong;Choi, Yeon-Sung;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Young-Il
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2002
  • Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(T1) crystal(60$\times$60$\times$6 ㎣), PSPMT(position sensitive photomultimplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness(0~8 cm) and materials(air and acrylic) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10%(air) and 54%(acryl) with the parallel hole collimator and by 35%(air) and 63%(acryl) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera.

  • PDF

Development and evaluation of a compact gamma camera for radiation monitoring

  • Dong-Hee Han;Seung-Jae Lee;Hak-Jae Lee;Jang-Oh Kim;Kyung-Hwan Jung;Da-Eun Kwon;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2873-2878
    • /
    • 2023
  • The purpose of this study is to perform radiation monitoring by acquiring gamma images and real-time optical images for 99mTc vial source using charge couple device (CCD) cameras equipped with the proposed compact gamma camera. The compact gamma camera measures 86×65×78.5 mm3 and weighs 934 g. It is equipped with a metal 3D printed diverging collimator manufactured in a 45 field of view (FOV) to detect the location of the source. The circuit's system uses system-on-chip (SoC) and field-programmable-gate-array (FPGA) to establish a good connection between hardware and software. In detection modules, the photodetector (multi-pixel photon counters) is tiled at 8×8 to expand the activation area and improve sensitivity. The gadolinium aluminium gallium garnet (GAGG) measuring 0.5×0.5×3.5 mm3 was arranged in 38×38 arrays. Intrinsic and extrinsic performance tests such as energy spectrum, uniformity, and system sensitivity for other radioisotopes, and sensitivity evaluation at edges within FOV were conducted. The compact gamma camera can be mounted on unmanned equipment such as drones and robots that require miniaturization and light weight, so a wide range of applications in various fields are possible.