• 제목/요약/키워드: District Heat

검색결과 239건 처리시간 0.027초

Small Nuclear Units에 의한 분산전원으로서의 전망(1) (Small Nuclear Units and Distributed Resource Prospects(1))

  • 이상성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.223-225
    • /
    • 2005
  • This paper will be introduce a new paradigm and prospects for energy supply system in near future which produces electric and district heat cogeneration with dispersed power grid with small nuclear power units. Recently, in nuclear field, a lot of effort has been done in nuclear major countries to develop small and medium reactor for enhancement of nuclear peaceful use as like in district heating, electric power generation, seawater desalination or hydrogen generation. This paper presents a new way and prospects for power source in distribution system by using the distributed & remote cogeneration system using small reactor.

  • PDF

지역냉방 열원의 수요모형에 관한 연구 (A Study on the Demand Modelling for District Cooling Energy Source)

  • 김진형;최병렬
    • 자원ㆍ환경경제연구
    • /
    • 제11권4호
    • /
    • pp.633-657
    • /
    • 2002
  • This study presents a demand modelling for landfill gas, which is used as alternative energy source for district cooling business. By analyzing the cost minimizing behavior of producer facing with three alternative energy sources such as electricity, cooling heat water, and gas, a demand function for landfill gas is derived from the optimal operating time of gas fired production facility, and estimated using unpublished data, which are associated with Seoul city's development plan for Sang-am area. The estimation results repeals that Seoul City could supply the land-fill gas of 13.76 million cubic meters each year at the price of about 16 won per cubic meters. However, if the investment costs associated with installation of gas collecting facilities are treated as sunk costs, annual amount of gas supplied is expected to increase to 14.22 million cubic meters at a lower unit price of 14.76 won.

  • PDF

실내화재진압로봇의 현장운용성 향상을 위한 실용성 평가 (Evaluation of Field working Improvement for an Indoor Fire-fighting Robot)

  • 곽지현;이우준;김종권
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.126-131
    • /
    • 2008
  • Fire-fighters have been struggling against heat and dense smoke caused by fire when it occurs especially at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been recently developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to promote field working ability of the fire-fighting robot. As a result, heat resistance, water discharge and field working appeared satisfactory.

  • PDF

지중송전 케이블 되메움 콘크리트의 열 저항 특성에 관한 연구 (A Study on the Thermal Resistance Characteristics of Backfill Concrete for Underground Power Cables)

  • 정원섭;권기주;김대홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.397-402
    • /
    • 2001
  • Due to the recent economic growth and the subsequent increase in demand of electricity, the construction of underground transmission line is also on the rise. Especially, in the metropolitan area, we have much obstruction in laying the line to the central district because of difficulties in procurement of construction land and the increase in the construction cost. Therefore, the necessity of increasing the capacity of transmission line has been suggested. In order to increase the capacity, the electric voltage and current intensity in size-limited lines should be also increased. But, eventually, it leads to the generation of unnecessary heat and the heat radiates through insulation cables and backfill concrete. So we need to develop the material that has good heat radiation characteristics. In this study, we developed and tested backfill concrete that can be a substitute for previously used backfill sand.

  • PDF

습식온돌시스템과 전기온돌시스템의 열성능 평가 (Thermal Performance Assessment of Wet Ondol and Electric Ondol System)

  • 한병조;구경완
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

Monitoring and spatio-temporal analysis of UHI effect for Mansa district of Punjab, India

  • Kaur, Rajveer;Pandey, Puneeta
    • Advances in environmental research
    • /
    • 제9권1호
    • /
    • pp.19-39
    • /
    • 2020
  • Urban heat island (UHI) is one of the most important climatic implications of urbanization and thus a matter of key concern for environmentalists of the world in the twenty-first century. The relationship between climate and urbanization has been better understood with the introduction of thermal remote sensing. So, this study is an attempt to understand the influence of urbanization on local temperature for a small developing city. The study focuses on the investigation of intensity of atmospheric and surface urban heat island for a small urbanizing district of Punjab, India. Landsat 8 OLI/TIRS satellite data and field observations were used to examine the spatial pattern of surface and atmospheric UHI effect respectively, for the month of April, 2018. The satellite data has been used to cover the larger geographical area while field observations were taken for simultaneous and daily temperature measurements for different land use types. The significant influence of land use/land cover (LULC) patterns on UHI effect was analyzed using normalized built-up and vegetation indices (NDBI, NDVI) that were derived from remote sensing satellite data. The statistical analysis carried out for land surface temperature (LST) and LULC indicators displayed negative correlation for LST and NDVI while NDBI and LST exhibited positive correlation depicting attenuation in UHI effect by abundant vegetation. The comparison of remote sensing and in-situ observations were also carried out in the study. The research concluded in finding both nocturnal and daytime UHI effect based on diurnal air temperature observations. The study recommends the urgent need to explore and impose effective UHI mitigation measures for the sustainable urban growth.

배열회수보일러 고압 슈퍼히터 튜브 열화도 평가 (Degradation Evaluation of High-Pressure Superheater Tube in Heat Recovery Steam Generator)

  • 송민지;최가현;채호병;김우철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.130-137
    • /
    • 2022
  • In this work, the degradation of high-pressure superheater tubes exposed to the flame of a duct burner in a heat recovery steam generator of a district heating system was evaluated. To assess the deterioration of the used superheater tube, the microstructure, microhardness, and tensile properties were investigated by comparison to an unused tube. The study found that a fin bound at the outer surface of the used tube became fragile only in the location facing the flame. This indicates that the tube was directly exposed to the flame from the duct burner or underwent abnormal overheating. While the unused tube showed a uniform value in hardness and equiaxial grain structure, the used tube revealed a decrease in hardness up to 105 HV and an increase in grain size with a plate-like morphology in the location facing the flame. The coarsening of the grain structure by the flame weakened the mechanical properties of yield strength, tensile strength, and elongation.

EnetPLAN을 이용한 지역난방시스템 가상 운전 분석 (Virtual Analysis of District Heating System Using ENetPLAN)

  • 안정진;이민경;김래현
    • 에너지공학
    • /
    • 제28권3호
    • /
    • pp.18-25
    • /
    • 2019
  • 본 연구에서는 발전사에서 숙련된 사용자가 코드를 입력하여 계산하는 프로그램의 문제점을 해소하고자 광역에너지네트워크 연구단은 확장성을 포함한 누구나 손쉽게 사용할 수 있는 지역난방 운전해석 프로그램 EnetPLAN을 국내 기술로 개발하였다. 이에 EnetPLAN과 시중에서 사용 중인 A프로그램과의 시뮬레이션을 통해 에너지네트워크상의 열원, 열수요 및 CHP(Combined Heat Plant:열병합발전) 운전 결과에 대해 비교하고자 하였다. 그 결과 EnetPLAN과 A프로그램의 에너지네트워크 상의 열 및 전력생산량은 열공급량과 축열조 운영방식의 시뮬레이션 결과에서 대부분 유사한 패턴으로 나타났다. 이는 EnetPLAN이 에너지네트워크 상에 존재하는 열병합발전시설의 다양한 운전모드에 따른 시뮬레이션 적용이 가능함을 확인할 수 있었다. 국내 기술로 개발된 EnetPLAN이 향후 현장에서 쉽게 적용할 수 있으며, 효율적인 운전 시뮬레이션 결과를 제시할 것으로 기대한다.

신재생에너지 기기로서 히트펌프의 신재생에너지 생산량 (Renewable Energy Production by Heat Pump as Renewable Energy Equipment)

  • 홍희기;최준영;임신영
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.551-557
    • /
    • 2017
  • Most European economies, Japan, and many governments have made it a major policy to expand the green business by disseminating heat pump technology, which has a large $CO_2$ reduction effect. The heat pump of all heat sources has been recognized as renewable energy and the policy to encourage has been implemented. In the recently revised Renewable Energy Law, the hydrothermal source (surface sea water) heat pump was newly included in renewable energy. In addition, the scope of application of heat pumps has expanded in the mandatory installation of renewable energy for new buildings, remodeling buildings, and reconstructed buildings based on this law. However application to heat pumps using all natural energy as heat source has been put off. In this revision, the ratio of renewable energy to the total energy produced by the heat pump was fixed at 73%, which depends on coefficient of performance of heat pump. The ratio of renewable energy is $1-1.8/COP_H$, and should be calculated including the coefficient of performance of the heat pump. Using a high efficiency heat pump or a high-temperature heat source increases the coefficient of performance and also reduces $CO_2$ emissions. It is necessary to expand the application of heat pumps as renewable energy equipment and to improve the correct calculation of renewable energy production.

LNG 냉열이용 지역집단 냉방시스템에 대한 연구 (A Study on the District Community Cooling System using LNG Cold Energy)

  • 김청균;김승철
    • 한국가스학회지
    • /
    • 제14권6호
    • /
    • pp.27-30
    • /
    • 2010
  • 본 논문은 LNG 냉열에너지를 이용한 지역집단 냉방에너지 시스템을 공급하기 위한 시스템 공정설계에 관한 연구이다. 새로이 개발한 LNG 냉방시스템은 여러 개의 열교환기, LNG 저장탱크, 열매체 저장탱크, 여러 개의 냉열에너지 저장탱크, 가스냉방기, 압축기, 정압기, 저온 및 고온에너지 공급배관 등으로 구성되도록 설계하였다. 또한, 가스냉방기는 여름철에 도시가스 소모량에 의해 충분하지 못한 LNG 냉열에너지를 안정적으로 공급하기 위해 설치되었다. 냉방에너지 공급시스템은 공기라는 열매체와 200kcal/kg의 냉열에너지를 가진 LNG 사이의 열교환 작용에 의해 냉방에너지를 공급하는 효율성과 안전성을 함께 갖추고 있다. 또한, LNG 냉열에너지를 이용한 지역집단 냉방에너지 공급시스템은 공기중으로 CO2나 프레온 가스를 방출하기 않는다는 장점을 간고 있다.