전지전력저장시스템의 국내적용을 위한 경계성 검토에 관한 연구 (Economic Evaluation for the Domestic Application of the Battery Energy Storage System(BESS))

  • 김응상;김호용;김재철;임성정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.610-612
    • /
    • 1995
  • This paper presents the economic evaluation of battery energy storage system(BESS). Application target of the BESS was decided to both the distribution substation and single customer. 1MW/4MWh BESS under research and development in KERI was used for example. We analyzed and compared BESS with conventional combind cycle. The result shows that BESS is more economic than conventional combind cycle.

  • PDF

ANSI/IEEE를 적용한 초고압 차단기의 차단시험 (Breaking test of UHV circuit breaker by ANSI/IEEE standard)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

고압 커패시터 투입시 수용가측 엘리베이터 정지사례 분석 (Case Study of Power Factor Correction Capacitors On Upseting Elevator)

  • 조남훈;전영재;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.33-35
    • /
    • 2003
  • Capacitor switching is essential for the economic operation, and proper voltage control of KOREA electric utility distribution system. Voltage transients produced by capacitor switching (around 2.0 per unit at substation and 2.5 or less per unit at customer site, and lasting less then 1ms) do not have the magnitude or duration to interfere with the operation of computers, but they do disrupt the operation of adjustable speed drivers. The result of our research, ASD manufacturers should team from the computer industry and design products that will operate satisfactory in the electrical envelopment in which they will be placed. In this case history, the inductors on the input to ADSs in order to prevent nuisance tripping from capacitor switching(and other causes within the apartment) proved to be an effective, low-cost solution.

  • PDF

무효전력 보상여유를 고려한 SVC와 ULTC의 협조제어 (Coordinated Control of SVC and ULTC Considering Reactive Power Compensation Margin)

  • 문경섭;손광명;이태기;이송근;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.351-357
    • /
    • 1999
  • This paper proposes the coordinated control of SVC and UTLC at the distribution substation to get larger operating margin of SVC for the voltage stability control by reactive power compensation. In the conventional method, ULTC doesn't respond to the variation of source voltage, so SVC has the entire responsibility for it. It could cause the lack of operating margin of SVC in some condition. It, however, is important to secure an operating margin for the dynamic stability control in emergancy. This paper proposes the coordinated control method that SVC controls the supply voltage and ULTC respond to the SVC compensation valve based on the relation between SVC compensation and ULTC tap position. The numerical simulation verifies that the proposed system could increase the operating margin of SVC compared with the conventional system.

  • PDF

재폐로방식이 전력용 변압기에 미치는 영향 평가 (Evaluation of Damage from Reclosing Scheme for Power Transfromer)

  • 오정환;윤상윤;임성정;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.177-183
    • /
    • 1999
  • This paper presents how to evaluate the transformer damage caused by reclosing scheme at the distribution substation. We describe a quantitative relationship between the reclosing scheme and the number of fault current flowing through transformer wsing the probability of a reclosing success/failure. The transformer damage from reclosing scheme is presented using a weight function and a damage function. A weight function is associated with the number of reclosing attempts and the reclosing deadtime to consider cumulative stress caused by reclosing scheme. A damage function is associated with a transformer impact ratio and a transformer functional life. In the case study, the transformer damage is simulated for the probability of a reclosing success. And the evaluation of transformer damage using KEPCO's operation data is performed.

  • PDF

변전소 자동화를 위한 위상구조 처리에 관한 연구 (A Study on Topology Processor for Substation Automation)

  • 이흥재;왕인수;강현재;이수길;홍준호;김도진;강민찬;임찬호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.21-22
    • /
    • 2007
  • Topology processing is indispensable basic function as it generate a real-time BUS-BRANCH model in Energy Management Systems because most application softwares such as state estimation, power flow, etc., require BUS-BRANCH circuit data. This paper propose an expert system to generate BUS-BRANCH circuit model using Artificial Intelligence technology and it is applied to 154kV distribution substations.

  • PDF

Steiner Tree 이론을 이용한 우편물 교환센터인 최적 워치선정 (Optimal Location of Mail Distribution Center using Steiner Tree)

  • 양성덕;유웅규;이상중
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.82-87
    • /
    • 2008
  • 국내 택배시장은 과거 몇 개의 업체에서 독점해왔으나 현재는 대기업들과 수많은 중소기업들이 참여하고 있어 경쟁이 심화되고 있다. 우편물의 신속한 배송과 운송비용의 최소화는 매우 중요하며 이를 위하여 운송거리의 최단 거리화가 우선 필요하다. 본 논문은 전국의 주요 도시에 배치된 우편집중국을 기하적으로 가장 짧게 연결하는 교환 센터의 최적 위치를 찾는 방법을 제시한다. 송전계통의 routing, 배전선로망의 최적화 등에 이용되고 있는 Steiner Tree이론을 최단거리 우편물 운송망 구축에 적용하였다. Steiner Tree이론으로부터 선정된 위치에 교환센터를 설치할 경우, 운송비를 절감하여 경영수지를 개선할 뿐 아니라 신속한 배달을 최우선으로 하는 택배 시장에서 우위를 점할 수 있을 것으로 기대된다. Steiner Tree 이론은 차기 초고압 선로를 최단거리로 연결하는 전력소의 위치선정 등에도 활용될 수 있을 것으로 사료된다.

전자기 반발 구동장치를 사용한 고속 차단기 개발 (Development of High Speed Circuit Breaker using Electromagnetic Repulsion Actuator)

  • 황광수;김영일;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.441-448
    • /
    • 2022
  • 배전분야 전력계통에 적용되는 보호기기류는 변전소 차단기, 배전선로의 리클로저, 최소 전류 용량 회로, 고장구간 차단기 등이 있다. 이들은 부분 정전이나 대규모 사고를 방지하고 선로의 순간고장 또는 영구고장 발생 시 정상 계통이 건전성을 유지할 수 있도록 광역 정전 파급을 방지한다. 그러나 사고가 발생할 경우 변전소 차단기와 배전선로 보호기기 간의 보호협조 미비로 인하여 광역 정전을 초래할 수 있다. 더 좋은 전력시스템의 건전성을 확보하기 위하여 1주기(16ms) 이내로 동작하는 차단기를 개발할 필요성이 요구된다. 본 연구에서는 친환경 가스절연 방식의 고속도 차단기를 개발하였으며, IEC 62271-111 표준에 기반한 시험에서 우수한 결과를 얻었다. 이 기기는 고장구간을 정확하고 빠르고 신속하게 분리하여 광역 정전 예방에 기여할 것으로 기대된다.

고성토 암버력 동다짐 지반에 시공된 PHC 말뚝의 거동특성 사례연구 (A Case Study of PHC Pile Behavior Characteristics on Dynamic Compacted High Rock Embankment)

  • 유남재;윤동균;배경태;김형석;이달호;박용만
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.519-526
    • /
    • 2010
  • The construction site for $\bigcirc\bigcirc$ transformer substation was located at a mountain valley. In order to prepare the site, the valley was first filled with crushed rock debris up to 63m. Since the main concern of this project is to minimize differential settlement of the foundation of transformer facilities, dynamic compaction was performed every 7m followed by reinforcement with EMP(Ez-Mud Piling). The EMP is one of bored piling methods, in which a hole is bored by means of air percussion and maintain by injecting Ez-Mud. Then a PHC pile (Pretensioned spun High strength Concrete pile) is embedded and finalized with a hammer. In this study, bearing capacities and long term behavior of a pile installed by EMP were investigated. To achieve these objectives, a series of tests such as static and dynamic load tests were conducted. In addition, a construction quality control standard was proposed based on the test results.

  • PDF

3선-단접지배전선로의 신뢰도개선을 위한 BEF 검출 알고리즘 (BEF Detection Algorithm to Improve Reliability of Three-Wire-Unigrounded Distribution Line)

  • Wan-Ki Min;Myeong-Ho Yoo;Seong-Hwa Kang
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.166-172
    • /
    • 1997
  • 배전선로에서 지락사고가 발생할 경우 신속한 검출은 감전사고 예방, 전기화재 방지 및 전력설비의 최적 운용에 있어서 중요하다. BEF(Back-fed Earth Fault)는 일종의 배전선로 지락사고로 부하측이 지락되는 경우이며 지락전류가 매우 작기 때문에 전류 검출에 의하여 배전 계통을 보호하기는 어려우나 배전 자동화 지역에서는 UVR(Under Voltage Relay)을 이용하여 보호한다. 그러나 배전 자동화가 되지 않은 지역에서는 UVR에 의해 보호가 불가능하므로 BEF의 특성을 해석하여 경제적으로 BEF를 방지하여야 한다. 본 논문에서는 RTDS, EMTP 시뮬레이션, ETSA의 실증 시험 데이터를 비교, 검토하여 기준 영상전류치를 설정하고, 이를 적용하여 측정된 영상 전류와 설정된 기준치를 비교하여 3상-단일 접지 배전 시스템의 정상 상태와 BEF의 구분이 가능한 BEF검출 알고리즘을 제안하였다. 다양한 조건에서 ETSA의 현장 시험에 적용하여 검토한 결과 3상-단일 접지 배전 시스템에서 제안된 BEF 검출 알고리즘의 타당성이 입증되었다. 따라서 본 알고리즘을 적용하여 배전선로를 운용하면 BEF에 의한 재해의 예방이 가능하리라 사료된다.

  • PDF