• Title/Summary/Keyword: Distribution requirement

Search Result 401, Processing Time 0.027 seconds

Integrated Order Scheduling with Limited Production Capacity of Multiple Producers in Distribution Requirement Planning Systems ( DRPs ) (DRP 시스템에서 생산지의 생산능력을 고려한 통합발주계획)

  • Yoo, Yeong-Joon;Rhee, Jong-Tae
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.17-26
    • /
    • 2000
  • This paper presents an integrated order scheduling method with the improved DRP concept for multi-echelon distribution system that has the constraint of limited production capacity of producers. The proposed method reflects the dynamic characteristics of inventory level changes in the regional and central distribution center. The simulation is done with two models : the traditional DRP method and the proposed method presented in this paper. From the results, the latter is more efficient than the former in cost, customer's service level as well as balanced production load on each producer.

  • PDF

Viscosity Study to Optimize a Slurry of Alumina Mixed with Hollow Microspheres

  • Bukhari, Syed Zaighum Abbas;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.403-409
    • /
    • 2015
  • Porous alumina ceramics are involved in many industrial applications due to the exceptional properties of these products. This study addresses the preparation of porous alumina ceramics using hollow microspheres as a pore-forming agent and slip casting as a green-body-forming technique. A uniform distribution of pores is a basic requirement of a porous material. This study investigates three different slurry systems, i.e., as-prepared alumina slurry, alumina slurry electrostatically dispersed by hydrochloric acid (HCl), and slurry dispersed by the commercial dispersant 'Darvan C-N'. At a low viscosity, the hollow microspheres in the slurry tend to float, which causes a non-uniform pore distribution. To avoid this phenomenon, the viscosity of the slurry was increased to the extent that the movement of hollow microspheres ceased in the slurry. As a result, a uniform pore distribution was achieved.

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

Application of Fluorescence/Scattering Technique to the Measurement of Spray Droplet Size in GDI Injector (직접 분사식 가솔린 인젝터 분무의 입경 측정에 형광/산란광법의 적용)

  • Kwak, Soo-Min;Ryu, Kyeong-Hun;Choi, Bong-Seok;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.353-358
    • /
    • 2000
  • To achieve the requirement for high fuel economy and low emissions, the research for GDI engines is recently very brisk in the whole world. This study was performed to measure distribution of average particle size in non-evaporating spray. The 2-D fluorescence/scattering images of fuel spray were captured simultaneously by visualization system composed of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the two light intensities, particle size distribution was obtained. The SMD measured by fluorescence/scattering technique was compared with it obtained by PDA. The experimental results show that the spray structure of GDI injector and temporal SMD distribution.

  • PDF

The Comparative Study of Software Optimal Release Time of Finite NHPP Model Considering Half-Logistic and Log-logistic Distribution Property (반-로지스틱과 로그로지스틱 NHPP 분포 특성을 이용한 소프트웨어 최적방출시기 비교 연구)

  • Kim, Hee Cheul
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • In this paper, make a study decision problem called an optimal release policies after testing a software system in development phase and transfer it to the user. In the course of correcting or modifying the software, finite failure non-homogeneous Poisson process model, presented and was proposed release policies of the life distribution, half-logistic and log-logistic distributions model which used to an area of reliability because of various shape and scale parameter. In this paper, discuss optimal software release policies which minimize a total average software cost of development and maintenance under the constraint of satisfying a software reliability requirement. In a numerical example, the parameter estimation using maximum likelihood estimation of failure time data make out, and software optimal release time was estimated.

Limiting Current Characteristics using Superconducting Fault Current Limiter in Power System (배전계통에 초전도 한류기 적용시 전류제한특성)

  • Kim, Jin-Seok;Lim, Sung-Hun;Ahn, Jae-Min;Moon, Jong-Fil;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.21-22
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) have proposed one of several countermeasures. Therefore, to introduce SFCL into power distribution system, the position of SFCL in power distribution system is selected among some cases. Each position changes fault current limiting characteristics and SFCL's requirement. In this paper, the characteristics of limiting fault current according to installed SFCL's location in power distribution system.

  • PDF

Application of Weibull Distribution Function to Analysis of Breakthrough Curves from Push Pull Tracer Test

  • Hyun-Tae, Hwang;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.217-220
    • /
    • 2003
  • In the case of the remediation studies, push pull test is a more time and cost effective mettled than multi-well tracer test. It also gives Just as much or more information than the traditionally used methods. But the data analysis for the hydraulic parameters, there have been some defections such as underestimation of dispersivity, requirement for effective porosity, and calculation of recovery of center of mass to estimate linear velocity. In this research, Weibull distribution function is proposed to estimate the center of mass of breakthrough curve for Push pull test. The hydraulic parameter estimation using Weibull function showed more exact values of center of mass than those of exponential regression for field test data.

  • PDF

The Study of Software Optimal Release Using Sensitivity Analysis (민감도 분석을 이용한 소프트웨어 최적방출시기에 관한 연구)

  • Shin, Hyun-Cheul
    • Convergence Security Journal
    • /
    • v.8 no.4
    • /
    • pp.121-126
    • /
    • 2008
  • It is of great practical interest to decide when to stop testing a software system in development phase and transfer it to the user. This decision problem called an optimal release policies. In this paper discussed to specify an optimal release policies. In this paper, propose an optimal release policies of the life distribution applied Erlang distribution of special pattern of Gamma distribution. In this paper, discuss optimal software release policies which minimize a total average software cost of development and maintenance under the constraint of satisfying a software reliability requirement. From Sensitivity Analysis, make out estimating software optimal release time.

  • PDF

Implementation of Simulated Annealing for Distribution System Loss Minimum Reconfiguration (배전 계토의 손실 최소 재구성을 위한 시뮬레이티드 어닐링의 구현)

  • Jeon, Young-Jae;Choi, Seung-Kyo;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.371-378
    • /
    • 1999
  • This paper presents an efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in large scale distribution systems of radial type. Simulated Annealing algorithm among optimization techniques can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing algorithm, we may use advanced Simulated Annealing algorithm. All constaints are divided into two constraint group by using perturbation mechanism and penalty factor, so all trail solutions are feasible. The polynomial-time cooling schedule is used which is based on the statistics calculation during the search. This approaches results in saving CPU time. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF

Application of Simulated Annealing for Loss Reduction in Distribution System (배전 계통에서 손실 감소를 위한 시뮬레이티드 어닐링의 적용)

  • Jeon, Young-Jae;Choi, Seung-Kyoo;Kim, Hun;Lee, Seung-Youn;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.335-337
    • /
    • 1998
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. Simulated Annealing can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing Algorithm, we may use advanced Simulated Annealing Algorithm. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF