• 제목/요약/키워드: Distribution of refrigerant flow

검색결과 51건 처리시간 0.022초

왕복동형 압축기의 경사진 원판형 밸브리드에 대한 압력분포 측정 및 유동해석 (Flow Analysis and Measurement of Pressure Distribution along Inclined Circular Valve Reeds of Reciprocating Compressor)

  • 윤정;박종호;김태민;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1942-1947
    • /
    • 2003
  • The valve is the key part which governs the efficiency, noise and reliability of the compressor, so the development of analytical model about valve performance is necessary. As the valve leed is opened and closed by pressure pulsation, the flow characteristic of the refrigerant passing the valve is very important. In the present study, a circular disk with inclination is assumed to be the valve reed of a reciprocating compressor and numerical analysis of three dimensional velocity fields are perfomed for the radial flow through the valve model. The effective flow and force area which are required to predict the efficiency of the valve are measured and compared with the numerical analysis in this research.

  • PDF

핀의 전도 열전달 및 과열도 변화에 따른 증발기 성능 특성에 관한 연구 (Effects of Fin Conduction and Superheat Unbalance on the Performance of an Evaporator)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.216-222
    • /
    • 2005
  • An experimental investigation was executed to determine the capacity degradation due to fin conduction and non-uniform refrigerant distribution in a multi-path evaporator with cross-counter flow. The finned-tube evaporator, which had a three-path and three-depth-row, was tested by controlling inlet quality, exit pressure, and exit superheat for each refrigerant path. The capacity reduction due to superheat unbalance between each path was as much as $25\%$ for non-cutting evaporator, even when the overall evaporator superheat was kept at a target value of $5.6^{\circ}C$. It indicates that the internal heat transfer within the evaporator assembly causes the partial capacity drop. The capacity of cutting-evaporator with respect to non-cutting evaporator was enhanced according to the increment of air flow rate when superheat or superheat unbalance increased.

CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가 (Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant)

  • 김은영;박동삼
    • 한국재난정보학회 논문집
    • /
    • 제18권3호
    • /
    • pp.550-559
    • /
    • 2022
  • 연구목적: 파이프는 기계, 전자, 전기, 플랜트 등 많은 산업 분야에서 응용기기로 널리 사용되고 있으며, 소방, 화학 등 안전 관련 분야에서도 널리 사용되고 있습니다. 제품의 다양화에 따라 배관 분야에서도 기술의 중요성이 높아지고 있습니다. 특히 기존 동관을 스테인리스강으로 변경하는 경우 구조해석이나 유동 해석을 통해 안전성과 유동특성을 평가할 필요가 있다. 연구방법: 자체 개발한 일체형 인서트형 커넥터인 6.35 소켓 모델의 유동 안전성은 CFD 해석을 이용하여 유동유발진동(FIV) 평가 과정의 4단계를 통해 진행하였다. 연구결과: 배관계 벽면에 작용하는 압력변동의 진폭은 3,780Pa이하의 수준으로 형성되며, 이는 냉매 배관의 운전압력이나 설계응력과 비교했을 때 매우 작은 수준의 압력으로, 난류에 의한 진동이 배관의 구조안전성에 미치는 영향은 미미한 수준인 것으로 나타났다. 결론: 유동 해석을 통하여 후크조인트 체결 시 발생하는 압력 및 진동 등을 검토한 결과 일반적인 배관계의 고유진동수가 50Hz 이하에서 형성되는 것을 고려했을 때, 난류유동에 의해 유발되는 진동이 배관계의 공진을 발생시킬 가능성은 희박한 것으로 판단된다.

압축기 밸브의 동적 특성에 대한 연구 (A Study on Dynamic Characteristics of Reed Valve in Hermetic Compressor)

  • 조성욱;박성근;김형석;임종윤
    • 소음진동
    • /
    • 제3권2호
    • /
    • pp.163-167
    • /
    • 1993
  • Suction and discharge valves of special type refrigerant compressor are designed by finite element method for effective valve design development procedure. It is well known that valve dynamic characteristics, for example, the natural frequencies and vibration modes, are necessary for the computer simulation of compressor valve dynamics, the analysis of flow patterns, noise, impact stresses and their propagation phenomena. This paper has analysed the natural frequencies and vibration modes for the first three orders under the given special boundary conditions and the experiments are conducted by laser holography. And also stress distribution is analysed and experiment by strain gage is followed.

  • PDF

이론적 열유동 및 랜덤 진동 해석을 적용한 EPS 보냉용기의 포장설계 (Packaging Design of EPS Cooling Box by Theoretical Heat Flow and Random Vibration Analysis)

  • 김수현;박상훈;이민아;정현모
    • 한국포장학회지
    • /
    • 제27권3호
    • /
    • pp.175-180
    • /
    • 2021
  • Although it has recently been regulated for use as an eco-friendly policy in Korea, the use of EPS (Expanded Polystyrene) cooling boxes, which are used as cold chain delivery insulation boxes for fresh agricultural and livestock products, is also increasing rapidly as e-commerce logistics such as delivery have increased rapidly due to COVID-19. Studies were conducted to optimize the EPS cooling container through internal air heat flow of CFD (Computational Fluid Dynamics) analysis and FEM (Finite Element Method) random vibration analysis using domestic PSD (Power Spectral Density) profile of the EPS cooling box to which the refrigerant is applied in this study. In the analysis of the internal air heat flow by the refrigerant in the EPS cooling box, the application of vertical protrusions inside was excellent in volume heat flow and internal air temperature distribution. In addition, as a result of random vibration analysis, the internal vertical protrusion gives the rigid effect of the cooling box, so that displacement and stress generation due to vibration during transport are smaller than that of a general cooling container without protrusion. By utilizing the resonance point (frequency) of the EPS cooling box derived by the Model analysis of ANSYS Software, it can be applied to the insulation and cushion packaging design of the EPS product line, which is widely used as insulation and cushion materials.

유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성 (Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction)

  • 권경민;정시영;김병주;정은수
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

왕복동형 압축기의 경사진 원판형 밸브리드와 밸브 시트의 기하학적 파라미터에 대한 압력분포 측정 및 유동해석 (Flow Analysis and Measurement of Pressure Distribution along Inclinde Circular Valve Reeds and Valve Seat Geometric Parameters of Reciprocating Compressor)

  • 박종호;윤정;김태민;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.828-833
    • /
    • 2003
  • This work analyzes the effects of the independent variation of different geometric dimensions of compressor valves on the effective flow and force areas using a circular valve plate, such as different geometry of the valve seat, and the valve reed is opened and closed by pressure pulsation, the flow characteristic of the refrigerant passing the valve is very important. In the present study, a circular disk with inclination is assumed to be the valve reed of a reciprocating compressor and numerical analysis of three dimensional velocity fields are performed for theradial flow through the valve model. The effective flow and force area which are required to predict the efficiency of the valve are required to predict the efficiency of the valve are measured and compared with the numerical analysis in this research.

  • PDF

난류 유동을 갖는 가스 포일 스러스트 베어링의 성능 예측 (Performance Predictions of Gas Foil Thrust Bearings with Turbulent Flow)

  • 문진혁;김태호
    • Tribology and Lubricants
    • /
    • 제35권5호
    • /
    • pp.300-309
    • /
    • 2019
  • Gas foil thrust bearings (GFTBs) support axial loads in oil-free, high speed rotating machinery using air or gas as a lubricant. Due to the inherent low viscosity of the lubricant, GFTBs often have super-laminar flows in the film region at operating conditions with high Reynolds numbers. This paper develops a mathematical model of a GFTB with turbulent flows and validates the model predictions against those from the literature. The pressure distribution, film thickness distribution, load carrying capacity, and power loss are predicted for both laminar and turbulent flow models and compared with each other. Predictions for an air lubricant show that the GFTB has high Reynolds numbers at the leading edge where the film thickness is large and relatively low Reynolds numbers at the trailing edge. The predicted load capacity and power loss for the turbulent flow model show little difference from those for the laminar flow model even at the highest speed of 100 krpm, because the Reynolds numbers are smaller than the critical Reynolds number. On the other hand, refrigerant (R-134a) lubricant, which has a higher density than air, had significant differences due to high Reynolds numbers in the film region, in particular, near the leading and outer edges. The predicted load capacity and power loss for the turbulent flow model are 2.1 and 2.3 times larger, respectively, than those for the laminar flow model, thus implying that the turbulent flow greatly affects the performance of the GFTB.

하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션 (Simulation of a two-stage absorption heat pump cycle using treated sewage)

  • 이용화;신현준;최국광
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF