• Title/Summary/Keyword: Distribution of body heat

Search Result 100, Processing Time 0.031 seconds

A literatual studies on the yupung(油風). (油風의 病因, 病機 및 治療藥物에 關한 文獻的 考察)

  • Kim, Nam-uk;Roh, Sek-seon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.162-179
    • /
    • 1998
  • In the literatual studies on the yupung(油風), the results were as follows. 1. Yupung(油風) was called 'Quijidu(鬼지頭)', 'Quichedu(鬼剃頭)', 'Ballak(髮落)' etc. It was a localized loss of hair in round or oval ares without any subjective symptom 2. The etiology and pathogenesis of Yupung were disorder of vital energy& blood circulation caused by deficiency of blood and wind-dryness syndrome, energy-stagnation and blood stasis, impairment of the liver & kidney. The treatments of Yupung were invigorating the liver & kidney, clearing away heat-evil and cooling blood, nourishing the liver & kidney, activating blood circulation to dissipate blood stasis etc, 3. In the frequency of prescription, the most numerous prescription is Shineuingyangjindan(神應養眞丹) and the next are Tonggyuhwalhyultang(通竅活血湯) & Chilbomiyumdan(七寶美髥丹), 4. In the frequency of medicine, the most numerous medicine is Radix Angelicae Sinensis(當歸) and the next are Rhizoma Rehmanniae Praeparatae(熟地黃) & Rhizoma Ligusiici Chuanxiong(川芎). 5. In classification of drug action, medicines of clearing away wind-heat evil and invigorating yin used to be very busy. 6. In classification of four characters, the most parts are warm medicine. 7. In classification of five tastes, the most numerous tastes are sweet and bitter tastes. 8. In classification of toxicity, the most is non-toxic medicines. 9. In classification of the channel distribution, the most is the medicine that belongs to liver channel. 10. In acupuncture theraphy, it was used 'GV20(百會)', 'G20(風池)', 'GV16(風府)', 'GV14(大椎)', 'LI4(合谷)' etc. in body acupuncture, was used 'S25(天樞)', 'GV14(大椎)', 'B13(肺兪)', 'LI11(曲池)' etc. in moxibustion.

  • PDF

Exact solution of a thick walled functionally graded piezoelectric cylinder under mechanical, thermal and electrical loads in the magnetic field

  • Arefi, M.;Rahimi, G.H.;Khoshgoftar, M.J.
    • Smart Structures and Systems
    • /
    • v.9 no.5
    • /
    • pp.427-439
    • /
    • 2012
  • The present paper deals with the analytical solution of a functionally graded piezoelectric (FGP) cylinder in the magnetic field under mechanical, thermal and electrical loads. All mechanical, thermal and electrical properties except Poisson ratio can be varied continuously and gradually along the thickness direction of the cylinder based on a power function. The cylinder is assumed to be axisymmetric. Steady state heat transfer equation is solved by considering the appropriate boundary conditions. Using Maxwell electro dynamic equation and assumed magnetic field along the axis of the cylinder, Lorentz's force due to magnetic field is evaluated for non homogenous state. This force can be employed as a body force in the equilibrium equation. Equilibrium and Maxwell equations are two fundamental equations for analysis of the problem. Comprehensive solution of Maxwell equation is considered in the present paper for general states of non homogeneity. Solution of governing equations may be obtained using solution of the characteristic equation of the system. Achieved results indicate that with increasing the non homogenous index, different mechanical and electrical components present different behaviors along the thickness direction. FGP can control the distribution of the mechanical and electrical components in various structures with good precision. For intelligent properties of functionally graded piezoelectric materials, these materials can be used as an actuator, sensor or a component of piezo motor in electromechanical systems.

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.28-37
    • /
    • 2001
  • The water quality in Yongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex. The study aims to simulate the current system that is necessary to build ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D model baroclinic model which considers tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most applicable on appearing the current system of the stratificated Yongil Bay difference of density. Form the results of simulation considered tidal current only, it can be clarified that the water body flows in the inner bay through the bottom layer and flows out the outer bay through the surface layer in Yongil Bay. And the fresh water from the Hyongsan river and the thermal discharge form POSCO have a little effect on the current system in Yongil Bay, but the diffusion of heat and salt has an important effect upon the formation of the density stratification of the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system in Yongil Bay.

  • PDF

Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions (냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계)

  • Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.

Thermal Flow Analysis and Design of KSTAR Thermal Shield Panel by Numerical Method (수치해석을 통한 KSTAR 주장치 열차폐 패널 열.유동 특성해석)

  • 김동락;김광선;노영미;조승연;김승현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.73-77
    • /
    • 2002
  • In order to derive the detailed design of Thermal Shield Cryopanel. which plays a role to make the Tokamak Nuclear Fusion Equipment work at both static and efficient conditions the commercially available software package FLUENT Version 5.3, was utilized. This study investigated the effects of thermal sources and distributions on the temperatures of Lid. Body. Base. and EH-Port Cryopanel by the numerical technique whose grid generations cover the solid and 9as region of the panel. The physical model of the Thermal Shield Cryopanel is that the 10mm diameter of the pipe with 1mm thickness is soldered on the Stainless steel Panel with 4mm thickness. The heat fluxes to the panel are assumed to be by thermal radiation in the vacuum space and by conduction through the supporters. The inlet conditions of Helium gas are 20 atmospheric Pressures and 60K temperature. The panel shapes with cooling Pipes and the operational conditions to keep appropriate temperature distribution of Thermal Shield Cryopanel Have been found and suggested.

A Survey on the Actual Wearing Conditions of Fire Fighter's Uniform (한국 소방복의 착용만족도 및 착용자 의견에 관한 조사연구)

  • 정정숙;이연순
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.11
    • /
    • pp.75-83
    • /
    • 1999
  • To develope an efficient fire fighter’s uniform for the fire fighting work and body protection, this study examined the regulations of fire lighter’s uniform and surveyed the actual wearing conditions, satisfaction degree, preferred color and design others. The results are as follows; 1. As for the satisfaction degree, the degree was normal in ordinary, low in working uniform and heat-proof uniform and very low in water-proof uniform about its design, size, color and materials. 2. As for the color, red was preferred for the working uniform and water-proof uniform. Blue, yellow and green was preferred next for corking uniform and yellow and blue for water-proof uniform. 3. As for the design, fire fighters wanted partial revision of the present uniform. They preferred stretchy training wear style and overact style in order. For the water-proof uniform, they preferred hip-length suit and pants and next to it they liked flee-length suit, waist belt and overact in order. 4. As for the regulations of the uniform, they wanted some addition in casual uniform, water-proof pants and water-proof gloves, and some deletion in the thermal barrier of water-proof uniform and ordinary uniform. 5. As for the distribution of the uniforms, the use of coupons was highly preferred.

  • PDF

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

Physiological Responses of Wearing Industrial Gaiters in a Hot Environment (더운 환경에서 산업용 각반 착용 시 인체생리반응)

  • Choi, Jeong-Wha;Park, Joon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.7
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

A Study on the Improvement of Manual Rice Cutters (인력대취검 개량제작시험연구)

  • 이철주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1580-1597
    • /
    • 1969
  • 1. The field test of our experiment comparing the traditional syckle and the new manually pulled cutter showed that the working efficiency of the manually pulled cutter is about two times higher than that of the syckle. The operator can standerect while using the manually pulled cutter, thus reducing fatigue. Because of the reduction in body fatigue, the operator is able to work more total hours, making the manually pulled harvester three times more efficient than the syckle. 2. The optimum angle for the V-shaped cutter blade varies according to the number of the hiller, but in manufacturing the cutter, the range must be controlled between $35^{\circ}{\sim}45^{\circ}$. 3. The radius of curvature of the V-shaped blade is closely related to the blade angle. The best results were obtained when the radii of curvature were r=32cm with $35^{\circ}$ angle, r=153mm with $45^{\circ}$ angle, and r=220mm with $40^{\circ}$ angle. 4. The hardness distribution test of the blade showed great differences between foreign made and domestic made blades. The heat treatment method must be greatly improved for superior hardness distribution. 5. Although the efficiency of the manually pushed cutter is equal to that of the manually pulled cutter, the manually pushed cutter is not only more expensive to produce but also has a much more complicated structure than the manually pulled cutter. Because of our rural economic conditions, the power harvester which is utilized in foreign countries can not yet be introduced here. Thus, the manually pulled cutter should be popularized in our rural areas until economic conditions will allow us to introduce power harvesters. 6. The use of the manually pulled cutter will make it possible for an operator to harvest an area in only one-third of the time that it would take to harvest the same area with a traditional syckle, and it will make it possible for an operator to earn about 8,000 won for harvesting 10 Jung-bo: such benefits will help in increasing farm income and will contribute to farm modernization.

  • PDF

Validation of a CFD Analysis Model for the Calculation of CANDU6 Moderator Temperature Distribution (CANDU6 감속재 온도분포 계산을 위한 CFD 해석모델의 타당성 검토)

  • Yoon, Churl;Rhee, Bo-Wook;Min, Byung-Joo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.499-504
    • /
    • 2001
  • A validation of a 3D CFD model for predicting local subcooling of moderator in the vicinity of calandria tubes in a CANDU reactor is performed. The small scale moderator experiments performed at Sheridan Park Experimental Laboratory(SPEL) in Ontario, Canada[1] is used for the validation. Also a comparison is made between previous CFD analyses based on 2DMOTH and PHOENICS, and the current model analysis for the same SPEL experiment. For the current model, a set of grid structures for the same geometry as the experimental test section is generated and the momentum, heat and continuity equations are solved by CFX-4.3, a CFD code developed by AEA technology. The matrix of calandria tubes is simplified by the porous media approach. The standard $k-\varepsilon$ turbulence model associated with logarithmic wall treatment and SIMPLEC algorithm on the body fitted grid are used and buoyancy effects are accounted for by the Boussinesq approximation. For the test conditions simulated in this study, the flow pattern identified is a buoyancy-dominated flow, which is generated by the interaction between the dominant buoyancy force by heating and inertial momentum forces by the inlet jets. As a result, the current CFD moderator analysis model predicts the moderator temperature reasonably, and the maximum error against the experimental data is kept at less than $2.0^{\circ}C$ over the whole domain. The simulated velocity field matches with the visualization of SPEL experiments quite well.

  • PDF