• 제목/요약/키워드: Distribution of body heat

검색결과 100건 처리시간 0.027초

PIC 렌즈 전조등 렌즈면의 온도분포에 관한 실험적 연구 (An Experimental Study on the Lens Surface Temperature Distribution of P/C Headlamp Using the Three Category of H4 Halogen Bulbs)

  • 박경석;강병도
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.158-165
    • /
    • 2002
  • This Paper deals with the headlamp lens surface temperature distribution of p/c headlamp using the three categories of H4 halogen bulbs. Glass is gradually replaced by P/C for the lens material off vehicle headlamp due to the weight reduction and stream lined body of a vehicle. With this trend, the newly established standards for a headlamp with a P/C lens in Europe requires that the heat generated by a bulb should not distort the lens surface. Also the requirements fur the bulb of a headlamp are being enforced in U.S.A & Europe. However, such requirements are not established yet in Korea. By using three kinds (60/55w, 100/90w, 130/90w) of H4 halogen bulbs in this experiment, the surface temperature distribution and Max. temperature on the lens were measured. The results of this study implies the necessity of requirement fur the bulb off headlamp.

Temperature transients of piston of a Camless S.I Engine using different combustion boundary condition treatments

  • Gill, KanwarJabar Singh;Singh, Khushpreet;Cho, H.M.;Chauhan, Bhupendra Singh
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.221-230
    • /
    • 2014
  • Simplified finite element model of spark ignition (SI) engine to analyse combustion heat transfer is presented. The model was discredited with 3D thermal elements of global length 5 mm. The fuel type is petrol. Internal nodal temperature of cylinder body is defined as 21000C to represent occurrence of gasoline combustion. Material information and isotropic material properties are taken from published report. The heat transfer analysis is done for the instant of combustion. The model is validated by comparing the computed maximum temperature at the piston surface with the published result. The computed temperature gradient at the crucial parts are plotted and discussed. It has been found that the critical top surface suffered from thermal and the materials used to construct the engine parts strongly influenced the temperature distribution in the engine. The model is capable to analyze heat transfer in the engine reasonably and efficiently.

강재의 레이저 표면경화 공정제어를 위한 경화층깊이의 실시간 측정에 관한 연구 (A study on in-process measurement of hardening depth for LASER surface hardening process control)

  • 우현구;박영준;조형석;한유희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.252-257
    • /
    • 1991
  • This paper proposed that the eddy-current measurement method can be used a means of in-process measuring the hardening depth in Laser surface treatment process. Also, this paper deal with the numerical analysis of magnetic flux distribution and experimental result of measurement. In Laser heat treatment process of steels, a thin layer of the substrate is rapidly heated to austenitizing temperature and subsequently cooled at a very fast rate due to the self-quenching by heat conduction into the bulk body, to produce a martensite structure which have low magnetic permeability. The eddy-current measurement method depends on the properties of material to be measured such as electric conductivity, magnetic permeability and geometry. In this paper, the hardening depth was measured by detecting relevant magnetic permeability changes caused by heat treatment of steels.

  • PDF

자동변속기 마찰요소의 동특성 해석 (Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission)

  • 최영종;정우진;김성원
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

박판형 레이저 용접재의 저주기 피로 특성 (The Low Cycle Fatigue behavior of Laser Welded Sheet Metal)

  • 김웅찬;곽대순;김석환;오택열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1025-1028
    • /
    • 2004
  • In this paper, we studied low cycle fatigue behavior of laser welded sheet metal that used automobile body panel. Specimens were manufactured as weld condition and sheet metal using automobile manufacturing company at present. For to know mechanical properties, micro Vicker's hardness test was performed of specimens. But, we can't confirm mechanical properties of weld bead and heat affected zone because laser weld makes very narrow weld bead and heat affected zone than other welding method. Therefore, we performed low cycle fatigue test with similar weldment, dissimilar weldment, similar thickness and dissimilar weldment, and dissimilar thickness and dissimilar weldment for fatigue properties of thickness and welding direction. As well, we analysis stress distribution of base metal, weld bead, and heat affected zone according to strain load using finite element method.

  • PDF

Coupled Analysis of Thermo-Fluid-Flexible Multi-body Dynamics of a Two-Dimensional Engine Nozzle

  • Eun, WonJong;Kim, JaeWon;Kwon, Oh-Joon;Chung, Chanhoon;Shin, Sang-Joon;Bauchau, Olivier A.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권1호
    • /
    • pp.70-81
    • /
    • 2017
  • Various components of an engine nozzle are modeled as flexible multi-body components that are operated under high temperature and pressure. In this paper, in order to predict complex behavior of an engine nozzle, thermo-fluid-flexible multi-body dynamics coupled analysis framework was developed. Temperature and pressure on the nozzle wall were obtained by the steady-state flow analysis for a two-dimensional nozzle. The pressure and temperature-dependent material properties were delivered to the flexible multi-body dynamics analysis. Then the deflection and strain distribution for a nozzle configuration was obtained. Heat conduction and thermal analyses were done using MSC.NASTRAN. The present framework was validated for a simple nozzle configuration by using a one-way coupled analysis. A two-way coupled analysis was also performed for the simple nozzle with an arbitrary joint clearance, and an asymmetric flow was observed. Finally, the total strain result for a realistic nozzle configuration was obtained using the one-way and two-way coupled analyses.

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

사출성형 및 열간가압 소결법으로 제작된 지르코니아 세라믹 임플란트의 소결물성 및 미세구조적 결함 (Sintered Properties and Microstructural Defects of Zirconia Ceramic Implant Fabricated by Injection Molding and Hot Isostatic Pressing (HIP))

  • 박현정;박정식;이종국
    • 열처리공학회지
    • /
    • 제36권4호
    • /
    • pp.215-222
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals, 3Y-TZP) ceramics are emerging as dental implant materials due to their superior optical and mechanical properties as well as excellent biophysical properties, in spite of low bioactivity. In this study, we investigated to sintered properties and microstructural defects of dental zirconia implants fabricated by ceramic injection molding and post-HIP (Hot isostatic pressing) processing and analyzed the processing parameters related with the obtainment of its high sinterd density. Sintered and microstructural parameters, i.e, apparent density, grain size and phase composition of zirconia implants fabricated by injection molding were dependent on the fixtute size and implant type. Maximum sintered density of 99.2% and minimum grain size of 0.3-0.4 ㎛ were obtained from large-scaled 2-body sample. In 1-body ceramic implant, high sintered density of 99.5% was obtained, but it had a little monoclinic phase and wide grain size distribution.

내열성장독소 생산 대장균의 판정 (Assay of Heat Stable Enterotoxin Producing E. coli)

  • 장우현;김문교;최명식;양남웅;고광욱;서정기
    • 대한미생물학회지
    • /
    • 제18권1호
    • /
    • pp.53-58
    • /
    • 1983
  • Enterotoxigenic E. coli is one of causative agents of the infantile diarrhea and traveler's diarrhea. A modified infant mouse assay(IMA) was developed for the detection of heat stable enterotoxin (ST) of E. coli isolated from diarrheal and control infants and assay system was established with using enterotoxin producing reference strains. The supernatant of the 24 hour-shaking culture of E. coli in Casamino Acid Yeast Extract Salt Broth(CYES-2) was ingested orally into the 2-4 day old ICR mice. After the mice were kept at $25^{\circ}C$ for 4 hours, they were sacrificed and the gut weight body weight ratio(GW/BW) was taken as the index of fluid accumulation induced by heat stable enterotoxin of E. coli. The results obtained were as follows; 1. The GW/BW responses of IMA tested with enterotoxin reference strains of E. coli(E. coli O148H28:$ST^+LT^+$, E. coli $O78H^-:ST^+LT^+$, E. coli O15H11:$ST^-LT^+$, E. coli O1H7:$ST^-LT^-$) appeared ta be ST dose-dependent, and not LT-dependent. From the dose-response curve, $25{\mu}l$ of culture supernatant was determined as test amount of the IMA. 2. Frequency distribution of IMA result from 643 strain of E. coli showed normal distribution at low GW/BW ratio and dispersed pattern at high GW/BW ratio. The GW/BW ratios of $0.056{\pm}0.004(mean{\pm}SD)$ of normal distribution which distributed from 0.044 to 0.068(P<0.01) was considered as ST negative. Thus the GW/BW ratio above 0.069 could be regarded as ST positive.

  • PDF