• 제목/요약/키워드: Distribution line carrier system

검색결과 19건 처리시간 0.046초

배전선반송 데이타통신에서의 주기적 임펄스노이즈의 발생특성 (The Originating Characteristics of Periodic Impulse Noises in the Data Communication System by Distribution Line Carrier Method)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권2호
    • /
    • pp.75-82
    • /
    • 1994
  • The existence of peroodic impulse noises in distribution line carrier (DLC) communication system is known to be the most serious obstacle for improving DLC communication quality in reliability and capacity. From the spectral points, impulse noises can be divided into baseband type and modulation type the noise width of whichs are much different each other. With each nose type, this study presents the basic characteristics in relation to what they originate from and how their spectrum properties are revealed. The baseband type impulse noise is normally caused from thyristor circuit running with low switching speed and the modulation type noise from the circuit of switching power supply. The base wave of modulation noise is shown to be the pulsuatic charging current to primary condenser in switching power circuit. The study result indicates also that placing the DLC carrier frequency away the band predominated by modulated noise especially from RCC type switching power circuit is very important in DLC design.

  • PDF

전력선 통신 기법을 활용한 변압기 식별 방법에 대한 고찰 (Study about Power Transformer Identification Method based on Power Line Communication Technology)

  • 변희정;최상준;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1006-1009
    • /
    • 2015
  • 3상 4선식 배전계통에서 특정 수용가가 어떤 변압기로부터 공급되는지를 결정하기 위한 전력선 통신방식을 활용한 식별 방법이 제안된다. 이러한 배전계통에서 전력선 통신 신호의 전달 특성을 분석하기 위한 변압기, 3상 선로, 부하 등에 대한 수치해석 모델을 기술한다. 배전선로에 고주파 전력신호를 주입하여 분석 한 결과 고주파 신호는 배전선에서 전달 능력에 한계 능력을 갖는다. 보통 배전계통의 전력 변압기는 그러한 고주파 신호의 전달을 차폐하게 된다. 이러한 제안된 전송제한 방법을 사용하여 변압기를 식별하는데 적용한다. 새로운 형태의 전력선 변압기 식별시스템이 설계 및 구현된다. 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위해서 일반 상업용 건물에서 실험이 행하여진다. 또한 MATLAB Simulink 시뮬레이터를 사용하여 개념에 대한 이해를 위한 시뮬레이션이 수행된다.

  • PDF

전력선 통신을 활용한 케이블 식별 기술 (Cable Identification Technology based on Power Line Communication)

  • 변희정;최상준;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.880-883
    • /
    • 2015
  • 배전선 케이블을 식별하는데 전력선 통신기술이 제안된다. 전력선 통신 기술의 응용 영역을 확대하게 된다. 고주파 신호는 배전선에서 전달 능력에 한계 능력을 갖는다. 보통 배전계통의 전력 변압기는 그러한 고주파 신호의 전달을 차폐하게 된다. 이러한 제안된 전송제한 방법을 사용하여 케이블을 식별하는데 적용된다. 새로운 형태의 전력선 케이블 식별시스템이 설계 및 구현된다. 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위한 실험이 행하여진다. 또한 시뮬링크 시뮬레이터를 사용하여 개념에 대한 이해를 위한 시뮬레이션이 수행된다.

  • PDF

Carrier 신호를 이용한 배전계통의 새로운 재폐로 방식 (A Novel Reclosing Scheme in Distribution System using Carrier Signal)

  • 고윤태;서훈철;이상봉;김철환;김재철;현옥배
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2115-2121
    • /
    • 2009
  • This paper proposes the new reclosing scheme considering the recovery time of SFCL in distribution systems which is based on variable dead time control. The main idea is that it uses the carrier signal to distinguish whether the fault is instantaneous or permanent after tripping the line by recloser. The system and SFCL is modeled by using Electromagnetic Transient Program(EMTP) and the validity of the reclosing scheme presented in this paper is analyzed according to the fault resistance, the recovery time of SFCL and the fault clearing time.

배전선 반송 데이타통신에서의 전원동기 위상대역한정 전송에 의한 주기적 노이즈신호 회피특성에 관한 연구 (A Study on the Characteristics of the Synchroneous Data Transmission by the Phase Band Limit of AC Power Wave to Avoid the Periodic Noises in the Data Communication System of Distribution Line Carrier Method)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.78-84
    • /
    • 1994
  • The location of periodic noises in phase of AC power wave reveals to be specific according to the noise kinds which can be generally classified into modulation and baseband types in DLC. The former noise type has constant noise phase which is originated from switching mode power supplies and the latter normally caused from thyristor circuit of low switching frequency is compared to be more dispersive than the other.

  • PDF

전력선 통신을 이용한 집단주택 안전관리 시스템 (Security Monitoring System for Apartment House Building Using Paver Line Carrier)

  • 김인수;김관호;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

배전자동화용 배전선 반송통신방식의 전송특성시험 (Field Testing of Distribution Line Carrier Communication System for Automation Distribution System)

  • 허영;오원록;오상기;김관호;김요희;현덕화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.712-717
    • /
    • 1989
  • A communication system through distribution lines was developed for distribution automation. Since all facilities in distrbution systems are connected by distribution lines, economical communication systems can be realized by using these lines as data transmission lines. But it has a problem in transmission reliability bcause of its sensitivity to noise and impeadance. Therefore, to cope with this problem. measurement and analysis of the communication characteristics are made according to the influence of load impeadence change, signal level and noise generated in load. Field tests were carried out at Kyung Ki branch of the KEPCO for half year starting in Feburary 1988.

  • PDF

전력선 통신을 위한 2-반송파 DS방식의 특성과 MODEM의 구현 (Performance of 2-Carrier DS system and its MODEM designed for Power Line Transmission)

  • 김인태;이무영
    • 한국통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.582-590
    • /
    • 1994
  • 전력선 통신을 위한 간단하면서 융통성이 큰 2-반송과 DS방식의 데이터 전송모뎀을 구현하고, 그 특성을 해석적으로 검토하였으며 실험을 통해 이것을 확인 하였다. 제안된 시스템은 DS모뎀 출력에 극성에 따라 독립된 2개의 반송파 주파수를 할당하여 전송케 하므로서 완전한 DSSS 동작을 보장 하도록 한다. 수신단말기의 두 포락선 검파출력은 재래방식 처리 비교기에 입력되지 않고 먼저 DS 상관기에 입력시켜서 그 출력을 잡음과 비교판정 하게 된다. 이때, 역확산되어 약화된 잡음전략이 신호와 비교되기 때문에 데이터의 에러율은 현저하게 개선 된다. 이 시스템은 구성이 비교적 간단함에도 불구하고, 2400bps의 데이터를 전송 할때, 재래식의 FSK 방식에 비하여 10dB정도 더 높은 선로잡음아래에서도 에러율 10 정도를 유지할 수가 있다.

  • PDF

Carrier-Mediated Tissue Distribution and Blood-Brain Barrier Transport of New Quinolones

  • Tsuji, Akira
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1997년도 춘계학술대회
    • /
    • pp.57-63
    • /
    • 1997
  • Animal and clinical investigations have shown that fluoroquinolones, new quinolone antibacterial agents (NQs), are well absorbed across the intestinal tract, with a bioavailability of 60-90% after oral administration. Although some types of carrier-mediated intestinal transport mechanisms have been reported for enoxacin (ENX), ofloxacin (OFLX) and sparfloxacin (SPFX), recent results using a human intestinal epithelial cell line, Caco-2, indicated a passive or nonsaturable transport of SPFX, one of the most hydrophobic NQs. The mechanism underlying the intestinal absorption of NQs is still largely unknown. The distribution of NQs into peripheral tissues including erythrocytes is very rapid and their tissue-to-plasma concentration ratios (Kp) are considerably larger than those of inulin (an extracellular fluid space marker), in spite of almost complete ionization of NQs at the physiological pH. Our findings suggest that OFLX and lomefloxacin (LFLX) are taken up by rat erythrocytes via a transport system common to that of a water-soluble vitamin, nicotinic acid.

  • PDF

전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구 (Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology)

  • 변희정;최상준;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.505-508
    • /
    • 2016
  • 도심에서 배전선로는 지중과 가공 선로의 구성, 연가, 건물과 나무로 인한 시야 방해로 추적하기가 어렵다. 이러한 3상 4선식 배전계통에서 특정 수용가가 어떤 변압기 또는 어떤 배전선로로부터 공급되는지를 결정하는 것이 현장의 전기 기술자에게 어려운 문제다. 배전선로의 부하 평형등을 위해 선로의 정확한 추적기술이 필요하다. 본 논문에서는 소전력 고주파 신호를 사용하는 전력선 통신을 활용한 식별 방법을 제안한다. 배전선로에 고주파 전력 신호를 주입하여 분석 한 결과 고주파 신호는 배전선 및 변압기에서 전달을 억제하게 된다. 이러한 제안된 전송제한 방법을 사용하여 변압기도 식별하고 배전선로도 식별하고자 한다. 배전계통에서 전력선 통신 신호의 전달 특성을 분석하기 위한 변압기, 3상 선로, 부하 등에 대한 시뮬레이션 해석 모델을 기술한다. 그리고 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위해서 일반 상업용 건물에서 실험이 행하여진다. 또한 MATLAB 시뮬링크를 사용하여 개념에 대한 이해를 위한 시뮬레이션이 수행된다.

  • PDF