• Title/Summary/Keyword: Distribution limit

Search Result 1,179, Processing Time 0.035 seconds

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

Distribution of Indicator Plant of Climate Change in Major Islands of the Korean Peninsula (한반도 주요 도서 지역의 기후변화 지표 식물 분포)

  • Kim, Hyun Hee;Mizuno, Kazuharu;Lee, Ho Sang;Koo, Jae Gyun;Kong, Woo Seok
    • Journal of Environmental Science International
    • /
    • v.30 no.1
    • /
    • pp.29-43
    • /
    • 2021
  • This study analyzed the status of climate-change indicator plants native to the main islands of the Korean peninsula, while elucidating their distribution characteristics. Information on flora from over 129 island locations, comprising more than 100 species of native plants, was collected, compiled into a database, and utilized as raw data. The distribution of 193 climate-change indicator plants was confirmed. The distribution area of broadleaf evergreen trees and ferns, including Mallotus japonicus and Cyrtomium falcatum, was relatively wide. In contrast, the distribution of common northern plants such as Corydalis turtschaninovii and Malus baccata was limited. If global warming persists, northern plant distribution is expected to decrease rapidly in the Korean Peninsula island region, while the northern limit line of the southern plants is expected to migrate further northward. During this process, it is likely that the plant congregation structure and species diversity within the island region will change dynamically. In this study, comparative analyses between species and regions were conducted by assessing the relative frequency of their occurrence, and six types of botanical geographic distribution patterns were noted.

Distribution of Evergreen Broad-leaved Plants and Climatic Factors (한반도 상록활엽수의 지리적 분포와 기후요소)

  • 구경아;공우석;김종규
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.3
    • /
    • pp.247-257
    • /
    • 2001
  • The relationships between the distribution of 132 species, 61 genera evergreen broad-leaved trees and shrubs(EBTS) and climatic factors have discussed. The distributional patterns of EBTS were categorized into seven groups on the basis of the number of distributing sites, distributional attitudes and latitudes. Out of seven group. the cold-tolerant EBTS were common at groups I and II, along tilth Empetrum nigrum var. japonicum. Diapensia lapponics subsp. obovata of group III. However, the warmth-tolerant EBTS were rich at groups III. IV V, and VI The lower distributional limits of cold-tolerant EBTS in the groups I and UU decreased as one moves toward south. The upper distributional limit of warmth-tolerant EBTS in the groups III, IV and V decreased with increasing latitude. However. no clear distributional tendency is noticed in the groups VI and VII. The range of warmth-tolerant EBTS appear to show close relationship with the January mean temperature -4 $\^{C}$ and January mean minimum temperature -9$\^{C}$ than others. On the other hand, that of the cold-tolerant EBTS seem to respond well to the August mean temperature 19$\^{C}$ and August mean maximum temperature 26$\^{C}$ than others.

  • PDF

A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구)

  • Kim, Byungki;Kim, Giyoung;Lee, Jukwang;Choi, Sungsik;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1355-1363
    • /
    • 2015
  • In order to maintain customer voltage within allowable limit($220{\pm}13V$), tap operation of SVR(step voltage regulator) installed in primary feeder could be carried out according to the scheduled delay time(30 sec) of SVR. However, the compensation of BESS(battery energy storage system) is being required because the customer voltages during the delay time of SVR have a difficultly to maintain within allowable limit when PV system is interconnected with primary feeder. Therefore, this paper presents modeling of SVR to regulate voltage with the LDC(line drop compensation) method and modeling of BESS to control active and reactive power bi-directionally. And also, this paper proposes the coordination control modeling between BESS and SVR in order to overcome voltage problems in distribution system. From the simulation results based on the modeling with the PSCAD/EMTDC, it is confirmed that proposed modeling is practical tool for voltage regulation analysis in distribution system.

Goodness-of-fit tests for randomly censored Weibull distributions with estimated parameters

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.5
    • /
    • pp.519-531
    • /
    • 2017
  • We consider goodness-of-fit test statistics for Weibull distributions when data are randomly censored and the parameters are unknown. Koziol and Green (Biometrika, 63, 465-474, 1976) proposed the $Cram\acute{e}r$-von Mises statistic's randomly censored version for a simple hypothesis based on the Kaplan-Meier product limit of the distribution function. We apply their idea to the other statistics based on the empirical distribution function such as the Kolmogorov-Smirnov and Liao and Shimokawa (Journal of Statistical Computation and Simulation, 64, 23-48, 1999) statistics. The latter is a hybrid of the Kolmogorov-Smirnov, $Cram\acute{e}r$-von Mises, and Anderson-Darling statistics. These statistics as well as the Koziol-Green statistic are considered as test statistics for randomly censored Weibull distributions with estimated parameters. The null distributions depend on the estimation method since the test statistics are not distribution free when the parameters are estimated. Maximum likelihood estimation and the graphical plotting method with the least squares are considered for parameter estimation. A simulation study enables the Liao-Shimokawa statistic to show a relatively high power in many alternatives; however, the null distribution heavily depends on the parameter estimation. Meanwhile, the Koziol-Green statistic provides moderate power and the null distribution does not significantly change upon the parameter estimation.

A Study on the Priority Decision for Interconnection of PV System on Power Distribution System considering Customer Interruption Costs (정전비용 고려한 PV시스템의 배전계통 연계 우선순위 결정에 관한 연구)

  • Son, Chang-Nam;Han, Woon-Dong;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.163-168
    • /
    • 2014
  • In this paper, when photovoltaic systems are connected to distribution system, most effective capacity and location of PV system are studied considering customer interruption costs of power distribution system. The reliability model of PV system considering the duration of sunshine, the model of time-varying load and Roy Billinton test system (bus2 model) are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability and customer interruption costs for residential, general, industrial, and educational customer is evaluated.

Robust Control of Multi-Echelon Production-Distribution Systems with Limited Decision Policy (II)- Numerical Simulation-

  • Jeong, Sang-Hwa;Oh, Yong-Hun;Kim, Sang-Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.380-392
    • /
    • 2000
  • A typical production-distribution system consist of three main echelons representing the retailer, distributors, and a factory each with an on-site warehouse. The system is sufficiently general and realistic to represent many industrial situations. However, decision functions and parameters have been selected to apply particularly to the production and distribution of consumer durables. The flows included in the model are materials, orders, and those information flows needed to support the material and order-rate decisions. In this work, a realistic production-distribution system has been used as a basic model, which consists of three sectors: retailer, distributor, and factory. That system is a nonlinear 25th-order continuous system interconnected between the echelons. Using a modern control algorithm, a typical multi-echelon production-distribution system using a dynamic controller is numerically simulated in the nominal plant and in the perturbed plant when the piecewise constant manufacturing decision is limited by a factory manufacturing upper-limit due to capital equipment, manpower, and factory lotsize.

  • PDF

The Properties of Amylose of Cow Pea Starch (동부 전분의 아밀로오스 특성)

  • Kweon, Mee-Ra;Ahn, Seung-Yo
    • Applied Biological Chemistry
    • /
    • v.33 no.1
    • /
    • pp.39-42
    • /
    • 1990
  • The properties of amylose of cow pea starch were investigated. Amylose content of cow pea was 25.1 % and iodine binding capacity was 20.2 %. The ${\beta}-amylolysis$ limit of the amylose was 82.3%. The limiting viscosity number of the amylose fraction was 204 ml/g and the corresponding average degree of polymerization was 1,510 glucose units. The percent distribution of molecular weight of the amylose by gel chromatography was $1{\times}10^4$(0.7 %), $1{\times}10^4{\sim}4{\times}10^4$(4.1 %), $4{\times}10^4{\sim}5{\times}10^5$(44.6 %), $5{\times}10^5{\sim}4{\times}10^7$(49.6 % ).

  • PDF

Collapse Simulation with a Finite Element Limit Analysis for Thin-walled Structures Considering Forming Effects (성형효과를 고려한 박판 부재의 유한요소 극한해석을 이용한 붕괴거동해석)

  • Kim, Kee-Poong;Heh, Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.182-189
    • /
    • 2002
  • This paper is concerned with a collapse behavior analysis for a thin-walled structure considering farming effects. Numerical simulation is carried out with a finite element limit analysis in order to identify forming effects on collapse behavior of a thin-walled structure such as an S-rail. The formed S-rail contains fabrication histories such as residual stress, work hardening, non-uniform thickness distribution and geometric changes resulted from the forming process. The collapse behavior analysis of an S-rail with forming effects leads to different results from that without such effects. The present study deals with the collapse analysis of the S-rail fabricated with the typical forming, trimming and springback processes. Collapse properties such as the collapse load, the collapse mode and the energy absorption are calculated and investigated In order to identify forming effects. It is fully demonstrated that the design of thin-walled structures needs to consider the forming effects for a proper assessment of the load-carrying capacity and the deformation of the formed structures.

Finite Element Analysis and Formability Evaluation for Dimple Forming with Thin Sheet Metal (박판 딤플 성형을 위한 유한요소해석 및 성형성 평가)

  • Heo, Seong-Chan;Seo, Young-Ho;Ku, Tae-Wan;Song, Woo-Jin;Kim, Jeong;Kang, Beom-Soo
    • Transactions of Materials Processing
    • /
    • v.16 no.8
    • /
    • pp.621-628
    • /
    • 2007
  • Nowadays, Exhaust Gas Recirculation(EGR) Cooler is one of the most favorite systems for reducing the generation amount of $NO_x$ and other particle materials from vehicles burning diesel as fuel. Efficiency of the system is mainly dependent on its heat transfer efficiency and this ability is affected by net heat transferring area of the system. For that reason, several types of heat transfer tube such as dimple, wrinkle and spiral types that have large net area are used. However, it is difficult to manufacture the rectangular tube with dimpled type structure because it experiences too much strain around the rectangular tube surface during the forming process. For that reason, in this study, numerical simulation for forming process of non-symmetric dimple shape on a thin sheet metal was carried out. Furthermore, theoretical forming limit curves(forming limit diagram, forming limit stress diagram) were proposed as criteria of formability evaluation. From the results of finite element simulation in view of stress and strain distribution, it is found that the designed process has robustness and feasibility to safely manufacture the dimpled rectangular tube.