• 제목/요약/키워드: Distribution generator

Search Result 548, Processing Time 0.023 seconds

Dual-Halbach Array Permanent Magnet Tubular Generator for Free-Piston Generator

  • Beigi, Hassan Moradi Cheshmeh;Akbari, Sohrab
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.405-412
    • /
    • 2015
  • In this study, we describe the effects of changing the magnet shape of permanent magnets (PMs) in a rotor Halbach-array PM generator for reciprocating free piston generator applications. More specifically, the rectangular-shaped magnets were replaced by the trapezoidal-shaped magnets. The initial design, an analytical magnetic field solution of rectangular shaped magnets, is presented and air-gap magnetic flux density and thrust force were estimated. The results were compared to the finite element analysis (FEA) showing excellent agreement. Using FEA, the effect of the shape of the magnets on the flux density and thrust force waveforms is analyzed. Moreover, the proportion of the Halbach array in the machine was optimized by the means of a parametric search. The results obtained from the analytical calculations and FEA were validated by comparing to those of Radial-array PM generator.

Performance and Emissions Characteristics of Agricultural Generator and Air Heater using DME Fuel (DME를 이용한 농업용 온풍기와 발전기의 성능 및 배출가스 특성 연구)

  • KIM, SHIN;MIN, KYOUNIL;PARK, CHEUNKYU;LEE, HYUNCHAN;NA, BYUNGKI
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.4
    • /
    • pp.431-440
    • /
    • 2016
  • Electric or hydrogen energy source is expected to solve a various issues including energy security and exhaust pollution. However, it is required a lot of time and a variety of development to apply for commercialization. Therefore, it is needed to translation fuels between the future and the present. DME (Dimethyl Ether) can play a reduce exhaust emission from medium- to heavy-duty engines that are mostly used in commercial sector. It have applied to the DME fuel as a various alternative fuel including power generation in many countries. Especially, it is necessary to secure the energy of energy-poor areas that are widely distributed around the world. And Korea also has the energy-poor areas due to geographical characteristics. These areas has been covered by their own energy through some small diesel generators, diesel boiler etc. If DME fuels are supplied in new demand such as rural sector with energy poor area, DME fuel will be available in the wider sector. In this study, it investigated performance and emission characteristics of agricultural generator and air heater using DME fuel. So the existing equipment of generator and air heater was modified to apply DME fuel. And combustion characteristics and properties of exhaust gas according to the contents of the DME fuel were evaluated. DME fuel showed a potential application in agricultural generator and air heater.

A Study on Current Characteristics Based on Design and Performance Test of Current Generator of KRISO's Deep Ocean Engineering Basin

  • Kim, Jin Ha;Jung, Jae Sang;Hong, Seok Won;Lee, Chun Ju;Lee, Yong Guk;Park, Il Ryong;Song, In Haeng
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.446-456
    • /
    • 2021
  • To build an environment facility of a large-scale ocean basin, various detailed reviews are required, but it is difficult to find data that introduces the related research or construction processes on the environment facility. The current generator facility for offshore structure safety evaluation tests should be implemented by rotating the water of the basin. However, when the water in the large basin rotates, relatively large flow irregularities may occur and the uniformity may not be adequate. In this paper, design and review were conducted to satisfy the performance goals of the DOEB through computational numerical analysis on the shape of the waterway and the flow straightening devices to form the current in the large tank. Based on this, the head loss, which decreases the flow rate when the large tank water rotates through the water channel, was estimated and used as the pump capacity (impeller) design data. The impeller of the DOEB current generator was designed through computational numerical analysis (CFD) based on the lift surface theory from the axial-type impeller shape for satisfying the head loss of the waterway and maximum current velocity. In order to confirm the performance of the designed impeller system, the flow rate and flow velocity performance were checked through factory test operation. And, after installing DOEB, the current flow rate and velocity performance were reviewed compare with the original design target values. Finally, by measuring the current velocity of the test area in DOEB formed through the current generator, the spatial current distribution characteristics in the test area were analyzed. Through the analysis of the current distribution characteristics of the DOEB test area, it was confirmed that the realization of the maximum current velocity and the average flow velocity distribution, the main performance goals in the waterway design process, were satisfied.

LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators (LAN을 이용한 분산전원 연계 계통의 보호)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

Heat Transfer Analysis of Ice Slurry Generator (아이스슬러리 제빙장치의 열전달 해석)

  • Shin, You-Hwan;Lee, Yoon-Pyo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.984-989
    • /
    • 2009
  • The present study has been conducted to predict the temperature distribution in the core of the scraper type ice generator. The analytic model was simplified as the flow in the annular type cylinder, which had an inside wall moving in axial direction due to the rotation of screw and a fixed outside wall. The governing equations were arranged by the method of separation of variables. The results corresponded to the exact solutions of the Bessel function. The qualitative results such as general characteristics of heat transfer in annulus flow from outer cylinder wall to the inside wall were obtained. However the amount of the heat transfer was underestimated as low as $1/5{\sim}1/6$ of the designed value.

  • PDF

The Random Number Generator for the P.D.F of the Blocks ind the Buffer (버퍼내전송블럭의 확률밀도함수 추적을 위한 Random Number의 발생기에 관한 연구)

  • Park, Yhl
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.7 no.3
    • /
    • pp.130-134
    • /
    • 1982
  • In computer communication network, it is assumed that blocks are served at a rate of u messages per sec. The message blocks will be stayed in the buffer during the service time. In this case, the probability density distribution of the number of message blocks in the buffer space has been studied. When the average buffer space needed is minimum, the average block size will be specified by the relation between the input data and link infromation length. This relation proves to be perfect. The random number generator for this probability distribution is designed. The test result by making use of the random number generator has shown that is has little difference from the theoretical one.

  • PDF

A Study on Stable Operating for Buan S/S Byunsan D/L (2728 02) Power Distribution Area Connected with Wind Power Generator (부안 S/S 변산 D/L(2728 02) 공급구역을 대상으로 한 풍력발전시스템 계통연계 시 보호협조 방안)

  • Jang, Mi-Hye;Shin, Baek-Sik;Song, Weon-Jin;Kim, Yeong-Min;Kim, Dong-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.508-509
    • /
    • 2008
  • A creation of large and small scale wind farm was considered to proper already, as according to real Jeonbuk Saemangeum project. A grow larger to be construction of the new and renewable energy thema park as well as creation possibility of large scale wind farm afterward. Therefore, in this paper was proposed a counterplan on D/L protection cooperation of Buan S/S Byunsan D/L (2728 02) power distribution line in case of connected with wind power generator.

  • PDF

A Development of Energency Power Automatic Transfer Module in home (가정용 비상 전원 절체 모듈 개발)

  • Joo, Nam-Kyu;Kim, Kwan-Yuong;Kim, Nam-Ho;Lee, Jong-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

Eddy current loss calculation of flux shield in the large turbo generator using axi-periodic analysis (Axi-periodic Analysis를 이용한 대형 터보 발전기 단부 Flux Shield의 Eddy Current Loss 산정)

  • Kwon, Soon-O;Lee, Jung-Jong;Hong, Jung-Pyo;Nam, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.987-989
    • /
    • 2005
  • Axi-periodic analysis using magnetic vector potential is formulated in time harmonic field and applied to the field analysis for the end region of large turbo generator in this paper. By using axi-periodic analysis, the effect of flux shield, one of the structure placed in the end region of large turbo generator to prevent stator end from thermal damage, is studied, and eddy current loss in the flux shield is estimated for operation conditions. 3D FEA is used for the verification of presented analysis method. Because 3D flux distribution can be calculated with 2D modeling, magnetic field showing 3D distribution can be effectively calculated by axi-periodic analysis comparing with 3D FEA.

  • PDF

Distribution System Reconfiguration Considering Customer and DG Reliability Cost

  • Cho, Sung-Min;Shin, Hee-Sang;Park, Jin-Hyun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.486-492
    • /
    • 2012
  • This paper presents a novel objective function for distribution system reconfiguration for reliability enhancement. When islanding operations of distributed generators is prohibited, faults in the feeder interrupt the operation of distributed generators. For this reason, we include the customer interruption cost as well as the distributed generator interruption cost in the objective function in the network reconfiguration algorithm. The network reconfiguration in which genetic algorithms are used is implemented by MATLAB. The effect of the proposed objective function in the network reconfiguration is analyzed and compared with existing objective functions through case studies. The network reconfiguration considering the proposed objective function is suitable for a distribution system that has a high penetration of distributed generators.