• Title/Summary/Keyword: Distribution Journal

Search Result 56,960, Processing Time 0.063 seconds

Making Decision of the Maintenance Priority of Power Distribution System using Time Varying Failure Rate and Interruption Cost

  • Chu, Cheol-Min;Kim, Jae-Chul;Yun, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • The purpose of the this paper is to make decision of the maintenance priority of power distribution system using Time-Varying Failure Rate(TVFR) with interruption cost. This paper emphasizes the practical use of the reliability indices and interruption cost. To make a decision of maintenance priority on power distribution system equipment, the quantification of the reliability level should be represented as a cost. In this paper, the TVFR of power distribution system equipment applied in this paper utilizes analytic method to use the historical data of KEPCO. From this result, the sensitivity analysis on TVFR of equipment was done for the priority, which represents that high priority of the equipment has more effect on system reliability, such as SAIDI or SAIFI, than other equipment. By this priority, the investment plan is established. In this result, customer interruption cost(CIC) could be extracted, and CIC is used as weighting factor to consider a importance of customer. After that, the result calculated the proposal method in this paper is compared with other priority method, such as lifetime, failure rate or only sensitivity.

Active and Reactive Power Control of the Battery Energy Storage System interconnected with Power Distribution System (배전계통에 연계된 전지전력저장시스템의 유.무효전력 제어)

  • 김재철;문선호;최준호;김응상
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.127-133
    • /
    • 1999
  • Ths paper deals with the active and reactive power control of Battery Energy Storage System (BESS) during its interconnection operation to power distribution system When an interconnection operation of BESS to power distribution system, it is well suited for peak load shaving and distribution voltage compensation by controlling the real and reactive power. Equivalent mxiel of the distribution system and the BESS is derived and power flow equations are presented to control the real and reactive power of BESS. In this paper, to control the active and reactive power of BESS, $P-\delta$ and Q-V control method and ntJIrerical description is presented. To verify the proposed control method, using PSCAD/EMTDC program simulates the active and reactive power control of BESS.f BESS.

  • PDF

A Study ort the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. - in terms of the distribution of Outdoer Leisure-Facilities - (대도시 주민의 근린 실외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구)

  • 최기수;김한배;진양교;진상철;김석기
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.1
    • /
    • pp.141-156
    • /
    • 1995
  • This research is executed to find out the boundary of use by the conscious of local residents and to get the basic materials for the distribution of outdoor leisure-facilities. The map of use distribution of the outdoor leisure-facilities in a neighbourhood unit is made by applying a concept of the probabilistic contour line based on the choice model of outdoer leisure-facilities in the city of Seoul, Taegu an\ulcorner Kwangju. The results are listed as follows. 1) The use of outdoor leisure-facilities is influenced on the accessibility by the physical obstacles of streets and hills, etc. 2) The limitation of uses applying the model of choice probability are different according to the accessibility, the percentage of utilities and the arriving range based on the questionnaires which are surveyed the choice of outdoor leisure facilities of the residents of Seoul, Taegu and Kwangju. 3) The distribution of outdoor leisure facilities is decided by the limitation of use with the conscious of local residents.

  • PDF

The Analysis on Relation between Hamstring Length and Static Uprighting Balance (넙다리 뒤근육의 길이와 정적 기립균형과의 상관성 분석)

  • Nam, Kun-Woo
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate hamstring length during static uprighting position using weight distribution ratio. Methods: Ninety-six volunteers(56 males) were participated. The active knee extension test(AKE) was measured 3 times on both legs. The mean score of AKE was obtained. Then, the measurement of weight distribution ratio was observed 3 times on both legs, and its mean value was also calculated. Subjects were divided four groups based on their hamstring length measurement; both hamstring shortening group, left hamstring shortening group, right hamstring shortening group and normal hamstring length group. One-way ANOVA was employed to analyse collected data. Pearson's correlation was also hired to see any relationship between the hamstring length and the weight distribution. Results: In anterior/left area and posterior/right area, both hamstring shortening group left hamstring shortening group were superior to right hamstring shortening group and normal hamstring length group. Significant difference was existed statistically(p<.05) between groups. The correlation analysis between hamstring length and weight distribution ratio has not been shown any significant findings(Pant/post=0.733, Plt/rt=0.135). Conclusion: The results of the study may be applied to therapeutic management in posture and movement skill in musculoskeletal physical therapy.

  • PDF

Changes of the Postural Sway and Weight Distribution According to Cooling the Foot (발의 냉 적용이 자세 동요와 체중 분포에 미치는 영향)

  • Chung, Hyung-Kuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.19-27
    • /
    • 2009
  • Background: The purpose of this study was to examine changes of postural sway and weight distribution after cooling the foot. Methods: Ten men with no history of sensory, neurological and orthopedic disorders were participated in this study. They performed four methods: (1) non-treated feet group(control group); (2) both feet treated group; (3) right foot treated group; and (4) left foot treated group. The feet of them were put into ice box, then they stood more than forty seconds on EMED system with bared feet. Data on the moving length, velocity, and maximum velocity of COP and the weight distributions during thirty seconds only were measured in standing position. Results: (1) The moving length and velocity of COP were significant difference between control group and both feet treated group only(p<0.05). (2) The maximum velocity of COP was significant difference among control group and all experimental groups. (3) The changes of weight distribution were significant difference among control group and right/left foot treated groups. Conclusions: Cooling the foot led to increased postural sway and changed weight distribution patterns.

  • PDF

Visually Lossless Image Compression for Digital Cinema Distribution Based on DCI Specification (DCI 규격을 만족하는 디지털시네마 배급을 위한 시각적 무손실 압축 연구)

  • Kim, Chul-Hyun;Paik, Joon-Ki
    • Journal of Broadcast Engineering
    • /
    • v.13 no.1
    • /
    • pp.99-108
    • /
    • 2008
  • This raper analyzes the effect of visually lossless image compression for efficient distribution of digital cinema. Currently, distribution of digital cinema is carried out based on JPEG 2000 standard that has been selected by DCI. We first summarize characteristics of JPEG 2000, and then define the concept of visually lossless coding that plays an important role in digital cinema distribution. We provide a test for JPEG 2000 compression performance according to DCI specification for visually lossless. Based on the experiment, the result satisfies high quality for cinema distribution.

Probabilistic Power Flow Studies Incorporating Correlations of PV Generation for Distribution Networks

  • Ren, Zhouyang;Yan, Wei;Zhao, Xia;Zhao, Xueqian;Yu, Juan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.461-470
    • /
    • 2014
  • This paper presents a probabilistic power flow (PPF) analysis method for distribution network incorporating the randomness and correlation of photovoltaic (PV) generation. Based on the multivariate kernel density estimation theory, the probabilistic model of PV generation is proposed without any assumption of theoretical parametric distribution, which can accurately capture not only the randomness but also the correlation of PV resources at adjacent locations. The PPF method is developed by combining the proposed PV model and Monte Carlo technique to evaluate the influence of the randomness and correlation of PV generation on the performance of distribution networks. The historical power output data of three neighboring PV generators in Oregon, USA, and 34-bus/69-bus radial distribution networks are used to demonstrate the correctness, effectiveness, and application of the proposed PV model and PPF method.

Hardware-in-the-loop Simulation Method for a Wind Farm Controller Using Real Time Digital Simulator

  • Kim, Gyeong-Hun;Kim, Jong-Yul;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Eung-Sang;Lee, Ju-Han;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1489-1494
    • /
    • 2014
  • A hardware-in-the-loop simulation (HILS) method for a wind farm controller using a real time digital simulator (RTDS) is presented, and performance of the wind farm controller is analyzed. A 100 MW wind farm which includes 5 MW wind power generation systems (WPGS) is modeled and analyzed in RSCAD/RTDS. The wind farm controller is implemented by using a computer, which is connected to the RTDS through transmission control protocol/internet protocol (TCP/IP). The HILS results show the active power and power factor of the wind farm, which are controlled by the wind farm controller. The proposed HILS method in this paper can be effectively utilized to validate and test a wind farm controller under the environment in practice without a real wind farm.

Optimal Voltage Regulation Method for Distribution Systems with Distributed Generation Systems Using the Artificial Neural Networks

  • Kim, Byeong-Gi;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. This paper deals with the optimal algorithms for voltage regulation in the case where Distributed Storage and Generation (DSG) systems are operated in distribution systems. It is very difficult to handle the interconnection issues for proper voltage managements, because the randomness of the load variations and the irregular operation of DSG should be considered. This paper proposes the optimal on-line real time voltage regulation methods in power distribution systems interconnected with the DSG systems. In order to deliver suitable voltage to as many customers as possible, the optimal sending voltage should be decided by the effective voltage regulation method by using artificial neural networks to consider the rapid load variation and random operation characteristics of DSG systems. The simulation results from a case study show that the proposed method can be a practical tool for the voltage regulation in distribution systems including many DSG systems.

A Proposed High Voltage Distribution System of the Customer Inside for Reducing Power Loss (수용가내부 고압배전시스템의 전력손실감소효과)

  • Park, Hyung-Joon;Yun, Man-Soo;Chung, Chan-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.39-44
    • /
    • 2005
  • This paper is about the new distribution system of the electric customer inside. The power loss in the distribution system of the customer is disregarded and rarely managed so for. But, economically, this loss is not small quantity to ignore. So, in this paper, we suggest that the new distribution system of the electric customer inside by simply changing the locations of power transformer and other power facilities which is located inside of the customer. And we also show that the power loss is decreased with this systematic changing by approximated calculation.