• Title/Summary/Keyword: Distribution Journal

Search Result 56,960, Processing Time 0.066 seconds

The effect of precipitation conditions on the particle size and size distribution of zinc oxide prepared by high temperature precipitation (고온침전반응에 의한 산화아연 제조공정에서 입자의 형상 및 입도분포에 미치는 침전조건의 영향)

  • 주창식
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.16 no.2
    • /
    • pp.11-22
    • /
    • 1998
  • For the purpose of preparation of monodispersed spherical zinc oxide fine particles, an experimental research on the preparation of zinc oxide particles from zinc salts solutions by high temperature precipitation reaction was performed. Zinc oxide particles were precipitated from all the precipitation solutions tested if the precipitation temperature was higher than 60$^{\circ}$. As the precipitation temperature Increased until 80$^{\circ}$, the average particle diameter of zinc oxide particles decreased and the narrower particle size distribution were obtained. Spherical zinc oxide fine particles with relatively narrow particle size distribution were precipitated from the ZnSO$_4$ solutions with NaOH as precipitant. Final pH of precipitation solution had an effect on the amount of zinc oxide precipitated, but had no effect on the their particle size or size distribution.

  • PDF

Validation of the Detailed Design of the Label Distribution Protocol for the Multiprotocol Label Switching System (Multiprotocol Label Switching System의 Label Distribution Protocol 상세설계 검증)

  • 박재현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.5A
    • /
    • pp.889-901
    • /
    • 2001
  • 본 논문에서 Multiprotocol Label Switching 시스템을 위한 Label Distribution Protocol의 개발과 분석에 관해서 기술한다. 먼저 Gigabit Switched Router를 만들기 위해서, 상용화시 Carrier Class 제품에 적용하기 위한 LDP의 구현시 고려해야 될 사항에 대해 살피고, 상세 설계를 제안한다. IETF 표준에 의거한 LDP의 구현을 위한 상세 설계는 프로토콜 상태기계의 유도 트리와 프로세스 대수를 사용한 형식적 명세를 사용하여 제시한다. 본 논문에서는 제시된 유도트리와 프로세스 대수를 사용한 프로토콜 동작의 분석을 통해, 구현된 LDP의 상호 연동성과 완전성, 생존성, 도달성, 안전성을 검증한다. 또한 이를 사용하여 구현된 LDP가 기존 상용 제품들과의 연동성과 그 동작의 신뢰성을 확보할 것을 기대한다. 결과적으로 구현된 LDP의 프로토콜 동작들의 검증을 제공한다.

  • PDF

Distribution System Reconfiguration Considering Customer and DG Reliability Cost

  • Cho, Sung-Min;Shin, Hee-Sang;Park, Jin-Hyun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.486-492
    • /
    • 2012
  • This paper presents a novel objective function for distribution system reconfiguration for reliability enhancement. When islanding operations of distributed generators is prohibited, faults in the feeder interrupt the operation of distributed generators. For this reason, we include the customer interruption cost as well as the distributed generator interruption cost in the objective function in the network reconfiguration algorithm. The network reconfiguration in which genetic algorithms are used is implemented by MATLAB. The effect of the proposed objective function in the network reconfiguration is analyzed and compared with existing objective functions through case studies. The network reconfiguration considering the proposed objective function is suitable for a distribution system that has a high penetration of distributed generators.

An Optimal Current Distribution Method of Dual-Rotor BLDC Machines

  • Kim, Sung-Jung;Park, Je-Wook;Im, Won-Sang;Jung, Hyun-Woo;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.250-255
    • /
    • 2013
  • This paper proposes an optimal current distribution method of dual-rotor brushless DC machines (DR-BLDCMs) which have inner and outer surface-mounted permanent-magnet rotors. The DR-BLDCM has high power density and high torque density compare to the conventional single rotor BLDCM. To drive the DR-BLDCM, dual 3-phase PWM inverters are required to excite the currents of a dual stator of the DR-BLDCM and an optimal current distribution algorithm is also needed to enhance the system efficiency. In this paper, the copper loss and the switching loss of a DR-BLDCM drive system are analyzed according to the motor parameters and the switching frequency. Moreover, the optimal current distribution method is proposed to minimize the total electrical loss. The validity of the proposed method was verified through several experiments.

Numerical Calculation of Longitudinal Current Distribution in Grounding Electrode for Analyzing the Grounding Impedance (접지임피던스 분석을 위한 접지전극의 전류분포 수치계산)

  • Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • The current distribution passing through grounding electrode is required for calculating an impedance of grounding electrode using the electromagnetic field model. In this paper the numerical calculation for currents passing through a grounding electrode as a function of frequency was given. The proposed approach is based on the wire antenna model(AM) in the frequency domain. The Pocklington's equation driven from the wire antenna theory was numerically calculated by the Galerkin's method. The triangle function was applied to both the basis function and the weighting function. The current distribution of a horizontal ground electrode was simulated in MATLAB. Also these results were compared with the data obtained from the CDEGS HIFREQ calculation.

The Effect of Water Droplets on the Nano Particle Size Distribution using the SMPS System (SMPS 시스템에서 용매(물)가 나노입도측정결과에 미치는 영향)

  • Hwangbo, Seon-Ae;Chu, Min-Cheol
    • Journal of Powder Materials
    • /
    • v.20 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • In this paper we have studied the effect of water droplet size on nano-particle size distribution using SMPS(Scanning Mobility Particle Sizer)system. It can be seen that the unknown peak at >100 nm was caused by water droplets which did not dry completely when DI water was used as a solvent in the SMPS system. Therefore, it is important to dry water droplets generated from atomizer in the SMPS system when measuring the particle size distribution using less than 100 nm nano-particles in diameter. From this study, It can be concluded that the napion was a useful material as dryer ones and using EAG(Electro Aerosol Generator) as a particle generator was the most effective in reducing the effect of water droplets.

The Effect of Scale Parameter in Designing Reliability Demonstration Test for Lognormal Lifetime Distribution (대수정규 수명분포를 갖는 제품에 대한 신뢰성 입증시험에서 척도모수의 영향분석)

  • Kwon, Young Il
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • In the fields of reliability application, the most commonly used test methods for reliability demonstration are zero-failure acceptance tests since they require fewer test samples and less test time compared to other test methods that guarantee the same reliability with a given confidence level. For products with lognormal lifetime distribution, the value of scale parameter is usually assumed to be known in designing reliability demonstration tests. It is important to select correct values of scale parameters to guarantee the specified reliability with given confidence level exactly. The effect of using wrong values of scale parameters in designing reliability demonstration test for products with lognormal lifetime distribution is examined and selecting proper values of scale parameters for conservative reliability demonstration is discussed.

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

The Radial Distribution Functions of the Scaled OSS2 Water

  • Lee, Song Hi
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.6
    • /
    • pp.669-672
    • /
    • 2012
  • Classical molecular dynamics (MD) simulations using a scaled OSS2 potential originally derived from ab initio calculations are used to study the radial distribution functions of water. The original OSS2 water potential is shown to represent a glassy or an ice at ambient temperature, but the diffusion coefficient increases on increasing the temperature of the system or decreasing the density. This suggests scaling the OSS2 potential. The O-O, O-H, and H-H radial distribution functions and the corresponding coordination numbers for the scaled OSS2 potential, obtained by MD simulation, are in good agreement with the experiment results and calculations for the SPC/E water potential over a range of temperatures.

A Study on Thermal Performance of Heat Pipe for Optimum Placement of Satellite Equipment

  • Park, Jong-Heung
    • ETRI Journal
    • /
    • v.19 no.2
    • /
    • pp.59-70
    • /
    • 1997
  • A study on the operation of a heat pipe with two heat sources has been performed to optimize the heat distribution of satellite equipment. A numerical modeling is used to predict the temperature profile for the heat pipe assuming cylindrical two-dimensional laminar flow for the vapor, and the conduction heat transfer for the wall and wick. An experimental study using the copper-water heat pipe with the length of 0.45 m has been performed to evaluate the numerical model and to compare the temperature distribution at the outer wall for the non-uniform heat distribution. The results on temperature profiles for the heat input range from 29 W to 47 W on each heater are presented. Also the correlation between the heat input and the temperature increase is presented for the optimum distribution on two heaters. The result shows that the outer wall temperature can be controlled by redistribution of heat sources. It is also concluded that the heat source closer to the condenser can carry more heat while maintaining lower temperatures at the outer wall.

  • PDF