• Title/Summary/Keyword: Distribution Journal

Search Result 56,943, Processing Time 0.065 seconds

Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems (2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석)

  • 정채균;김상국;이종범;정영호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.

The guided field distribution characteristics in the ion-exchange channel glass waveguide (이온 교환 채널 유리 도파로의 도파광 분포특성)

  • 박정일;박태성;천석표;정홍배
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.332-339
    • /
    • 1995
  • In this paper, it was investigated the guided field intensity distribution of the channel in the silver & potassium ion-exchange glass-waveguide. The guided field intensity distribution analysis of ion-exchange glass-waveguide was based on the combination of the WKB dispersion relationship method with a Gaussian distribution function of refractive index profile and the Field Shadow method to the modeling of the channel waveguide. As the results of the channel waveguide modeling, it was represented 2-dimensional and 3-dimensional field distribution of ion-exchange glass waveguide.

  • PDF

Uniform Current Distribution among Conductor Layers in HTS Cables Using Inter-Phase Transformers (Inter-Phase Transformers를 이용한 고온 초전도 케이블의 층간 전류 등분배 방안)

  • 최용선;황시돌;현옥배;임성우;박인규
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.144-148
    • /
    • 2004
  • Uniform current distribution among conductor layers in HTS cables using IPTs (inter-phase transformers) was investigated. Conventional methods for current distribution, in which resistors are inserted to conductor layers, causes additional loss. In contrast, IPTs, which use magnetic coupling, make it possible that the current in parallel circuits is distributed uniformly with any load, and minimize the loss. In this study, IPTs were designed and fabricated for examination of uniform current distribution in the conductor layers of HTS cables. The ITP was designed through calculation of its impedance that can cancel the inductance of the conduction layers. The experimental setup consisted of four IPTs and four inductors that simulate the conductor layer inductance. Each layer was designed to feed 10 A. We examined the behavior of current distribution with IPTs for various layer inductances.

  • PDF

Distribution of a Sum of Weighted Noncentral Chi-Square Variables

  • Heo, Sun-Yeong;Chang, Duk-Joon
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.2
    • /
    • pp.429-440
    • /
    • 2006
  • In statistical computing, it is often for researchers to need the distribution of a weighted sum of noncentral chi-square variables. In this case, it is very limited to know its exact distribution. There are many works to contribute to this topic, e.g. Imhof (1961) and Solomon-Stephens (1977). Imhof's method gives good approximation to the true distribution, but it is not easy to apply even though we consider the development of computer technology Solomon-Stephens's three moment chi-square approximation is relatively easy and accurate to apply. However, they skipped many details, and their simulation is limited to a weighed sum of central chi-square random variables. This paper gives details on Solomon-Stephens's method. We also extend their simulation to the weighted sum of non-central chi-square distribution. We evaluated approximated powers for homogeneous test and compared them with the true powers. Solomon-Stephens's method shows very good approximation for the case.

Confidence Intervals and Joint Confidence Regions for the Two-Parameter Exponential Distribution based on Records

  • Asgharzadeh, A.;Abdi, M.
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.1
    • /
    • pp.103-110
    • /
    • 2011
  • Exponential distribution is widely adopted as a lifetime model. Many authors have considered the interval estimation of the parameters of two-parameter exponential distribution based on complete and censored samples. In this paper, we consider the interval estimation of the location and scale parameters and the joint confidence region of the parameters of two-parameter exponential distribution based on upper records. A simulation study is done for the performance of all proposed confidence intervals and regions. We also propose the predictive intervals of the future records. Finally, a numerical example is given to illustrate the proposed methods.

A new extended Birnbaum-Saunders model with cure fraction: classical and Bayesian approach

  • Ortega, Edwin M.M.;Cordeiro, Gauss M.;Suzuki, Adriano K.;Ramires, Thiago G.
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.4
    • /
    • pp.397-419
    • /
    • 2017
  • A four-parameter extended fatigue lifetime model called the odd Birnbaum-Saunders geometric distribution is proposed. This model extends the odd Birnbaum-Saunders and Birnbaum-Saunders distributions. We derive some properties of the new distribution that include expressions for the ordinary moments and generating and quantile functions. The method of maximum likelihood and a Bayesian approach are adopted to estimate the model parameters; in addition, various simulations are performed for different parameter settings and sample sizes. We propose two new models with a cure rate called the odd Birnbaum-Saunders mixture and odd Birnbaum-Saunders geometric models by assuming that the number of competing causes for the event of interest has a geometric distribution. The applicability of the new models are illustrated by means of ethylene data and melanoma data with cure fraction.

Resistance distribution in large area thin film type SFCLS (박막형 대면적 초전도 한류소자에서의 저항 분포)

  • 김혜림;최효상;현옥배
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.89-93
    • /
    • 2002
  • We investigated the resistance distribution n 4"diameter SFCLS. $YBa_2CU_3O_7$ films coated in-situ with a gold layer were patterned into 3 mm wide 142 cm long meander lines by Photolithography. The limiters were tested with simulated fault currents. The resistance was uniform all over the film except at the edge. At lower source voltages, CFCLs did not quench simultaneously and the resistance distribution was less uniform. Compared with 2" diameter SFCLS 4" SFCLS had similar values and time dependence of resistivity at similar electric fields The resistance distribution was more uniform in 4" SFCLS. The area at the edge where the distribution was not uniform was around 3 mm wide in SFCLs of both sizes. The experimental results were quantitatively explained with a heat transfer concept.

Multi-Agent System and its Applications to the Distribution Automation System (멀티에이젼트 기술의 배전자동화시스템 적용방안)

  • Lim, Il-Hyung;Choi, Myeon-Song;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This paper presents benefits of multi-agent system approach and its application to the distribution automation system. Special attention is devoted to the description of hardware and communication platform used to upgrade the conventional distribution automation system structure. Service restoration of primary distribution system is selected as an example of the multi-agent system application. Application of the algorithm for multi-agent based service restoration technique is disclosed in detail. Real field test in Gochang test center of KEPCO has been performed to establish the feasibility of proposed technique.

Analysis on the Protective Coordination in Power Distribution System with Superconducting Fault Current Limiter (배전계통에 초전도 전류 제한기 적용시 보호협조 분석)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.755-760
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. Therefore, to introduce SFCL into power distribution system, the analysis on protection in power distribution system with SFCL is essential. In this paper, the problems of the protective coordination in power distribution system with SFCL were described.

A Study on the Mathematical Modeling of Failure Rates Estimation for Asset Management of the Power Transformer (전력용변압기의 자산관리를 위한 고장률 추정기법의 수학적 모델링에 관한 연구)

  • MOU, SHUAILONG;Jang, Kyung-Wook;Baek, Seung-Myung;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.33-37
    • /
    • 2017
  • This paper describes the modeling of the failure rate estimation technique for applying the asset management technique to electric power facilities. There are many modeling techniques to estimate the failure rate. In this paper, the characteristics of the normal distribution, exponential distribution, weibull distribution, and piecewise linear functions are discussed. When evaluating reliability, the evaluation may be less meaningful if the sample data is insufficient. Therefore, Weibull distribution and piecewise linear function are adopted as the most suitable functions for estimating the failure rate of power facilities and the resulting failure rate function is derived.