• Title/Summary/Keyword: Distribution Fault

Search Result 1,024, Processing Time 0.033 seconds

A Design for a Hyperledger Fabric Blockchain-Based Patch-Management System

  • Song, Kyoung-Tack;Kim, Shee-Ihn;Kim, Seung-Hee
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.301-317
    • /
    • 2020
  • An enterprise patch-management system (PMS) typically supplies a single point of failure (SPOF) of centralization structure. However, a Blockchain system offers features of decentralization, transaction integrity, user certification, and a smart chaincode. This study proposes a Hyperledger Fabric Blockchain-based distributed patch-management system and verifies its technological feasibility through prototyping, so that all participating users can be protected from various threats. In particular, by adopting a private chain for patch file set management, it is designed as a Blockchain system that can enhance security, log management, latest status supervision and monitoring functions. In addition, it uses a Hyperledger Fabric that owns a practical Byzantine fault tolerant consensus algorithm, and implements the functions of upload patch file set, download patch file set, and audit patch file history, which are major features of PMS, as a smart contract (chaincode), and verified this operation. The distributed ledger structure of Blockchain-based PMS can be a solution for distributor and client authentication and forgery problems, SPOF problem, and distribution record reliability problem. It not only presents an alternative to dealing with central management server loads and failures, but it also provides a higher level of security and availability.

Variable Dynamic Threshold Method for Video Cut Detection (동영상 컷 검출을 위한 가변형 동적 임계값 기법)

  • 염성주;김우생
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4A
    • /
    • pp.356-363
    • /
    • 2002
  • Video scene segmentation is fundamental role for content based video analysis and many kinds of scene segmentation schemes have been proposed in previous researches. However, there is a problem, which is to find optimal threshold value according to various kinds of movies and its content because only fixed single threshold value usually used for cut detection. In this paper, we proposed the variable dynamic threshold method, which change the threshold value by a probability distribution of cut detection interval and information of frame feature differences and cut detection interval in previous cut detection is used to determine the next cut detection. For this, we present a cut detection algorithm and a parameter generation method to change the threshold value in runtime. We also show the proposed method, which can minimize fault alarm rate than the existing methods efficiently by experimental results.

Analysis of Over-current Characteristics in YBCO Coated Conductor (YBCO Coated Conductor의 과전류 특성해석)

  • Lee, C.;Nam, K.;Kang, H.;Ko, T.K.;Seok, B.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

A Study on Optimal Insulation Design of the Distribution Level HTS FCL (배전급 고온초전도 한류기 절연설계 최적화 연구)

  • Seok, B.Y.;Kang, H.;Lee, C.;Nam, K.;Ko, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.723-724
    • /
    • 2006
  • In this study, superconducting coil arrangements and cryostat concept design were conducted for the development of 13.2kV/630A bifilar winding type high temperature superconducting(HTS) fault current limiter(FCL) with YBCO coated conductor(CC) wire. The coil consists of several layers with unique non-inductive solenoid winding method. Six types of HTS coil arrangements were investigated for the optimal insulation design of HTS FCL. And, conceptual design of cryostat was conducted for the decrement of thermal invasion and the prevention of low voltage insulation breakdown in the LHe which is used as pressurization gas in sub-cooling condition of liquid nitrogen(LN2). As the results, it was found that the modified suspended type cryostat with horizontal coil arrangement is beneficial to the insulation design of 13.2kV level bifilar winding type HTS FCL.

  • PDF

A High-Resolution Transmission Electron Microscopy Study on the Lattice Defects Formed in the High Energy P Ion Implanted Silicon (고에너지 P이온 주입한 실리콘에 형성된 격자 결함에 관한 고분해능 투과전자현미경 연구)

  • 장기완;이정용;조남훈;노재상
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.12
    • /
    • pp.1377-1382
    • /
    • 1995
  • A high-resolution transmission electron microscopy study on the lattice defects formed in the high energy P ion implanted silicon was carried out on an atomic level. Results show that Lomer dislocations, 60$^{\circ}$perfect dislocations, 60$^{\circ}$ dislocation dipole and extrinsic stacking fault formed in the near Rp of as-implanted specimen. In the annelaed specimens, interstitial Frank loops, 60$^{\circ}$perfect disolations, 60$^{\circ}$dislocation dipoles, stacking faults, precipitates, perfect dislocation loops and <112> rodlike defects existed exclusively near in the Rp with various annealing temperature and time. From these results, it is concluded that extended secondary defects as well as the point defect clusters could be formed without annealing. Even at low temperature annealing such as 55$0^{\circ}C$, small interstitial Frank loops could be formed and precipitates were also formed by $700^{\circ}C$ annealing. The defect band annealed at 100$0^{\circ}C$ for 1 hr could be divided into two regions depending on the distribution of the secondary defects.

  • PDF

Numerical analysis of electromagnetic fields in Korean High Speed Train by transmission line matrix method (TLM 방법을 이용한 한국형 고속열차내의 전자계 해석)

  • Han, In-Su;Han, Young-Jae;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.466-469
    • /
    • 2008
  • As the industry develops, they are interested in the fault of electric machines and the effect on human beings by electromagnetic fields and waves which generate through much use of electric machines and appliances. In foreign country, they confirmed the standard about electromagnetic interference and compatibility(EMI/EMC) of electromagnetic fields and waves generating electricity transmission/distribution equipments and electric appliance. In Korea, such criteria are applied too. Before EMI/EMC standard is applied, it is important to prepare the plan to predict and reduce electromagnetic fields and waves which generate in the inner and the outer part of electric machinery. To solve such a problem, they calculated Maxwell's equations by finite element method(FEM) and finite difference method(FDM) in most papers. However, these methods have the disadvantage that mathematical expansions are complex and need much memory allocations for grid and mesh generations. In this paper, we introduce transmission line matrix(TLM) method that media of which trains consists are regarded as transmission lines for electromagnetic field calculation in Korean High Speed Train, calculate the electric and magnetic field, and analyze the results.

  • PDF

A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area (도심지 대심도 암반 굴착현장에서의 Face Mapping 적용사례)

  • Kim, Tae-Seob;Kim, Hyung-Min;Jo, Choong-Sick;Kang, Tae-Seong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1307-1316
    • /
    • 2009
  • In this case, powerfulness quorum of destruction side which we have expected are supposed general limit value for rock floor when retaining of earth on the section of rock floor in the urban area. For digging in the urban area, there are a lot of dislocations to be disadvantage for safety of digging ants. The displacement of the pondside didn't converged with the phase of the excavation. Also, the speed of displacement got higher than the percentages of risk in the construction. So, we put into operation Face mapping for checking special quality of dislocations which appear on the digging ants. This results were used to decide a destruction in the case of the final excavation by analyzing with other results. It was possible to know the unstable distribution of a fault line in Face Mapping and to get powerful lens of a surface of discontinuity by tests indoors and outdoors. The results were also used to make a solution. Therefore, It's a successful example using the Partial TopDown for stable digging. And it is important that Face Mapping have to be practiced for solving the uncertainty of ground organization when digging design in the urban city.

  • PDF

Supervisory Protection System of Microgird Interconnected to Low Voltage Grids (저압계통 연계형 마이크로그리드의 보호감시 시스템)

  • Jyung, Tae-Young;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • This paper mainly proposes the protective coordination scheme of the microgrid system. The microgrid protection is identical to the conventional protection system separating the normal part and contingency part to reduce damage when the contingency occur at power cables, facilities. But they are different in the protection type. The conventional protection system only considers unidirectional current. However the microgrid protection should be considered not only unidirectional current but also backfeed current because various microsources and loads are installed in the microgrid system. In case the contingency occurs in microsource, when microgrid is interconnected to grid, the protection system should be configured to not separate microgrid from grid before the microsource is isolated to microgrid. And in case of fault occur in power system, the microsources should not isolated to microgrid before the static switch at PCC is tripped to separate from power system. Considering these characteristic of microgird, this paper proposes the protective coordination scheme of microgrid and implemented the on-line real time monitoring system. Especially in case the microgrid is connected to low voltage distribution system with 220/380V voltage level, the proposed protection method with power IT technology can solve the problems when the existing protective devices only applied to the microgrid system.

Distributed OCSP Certificate Verification Model for Reducing Response Time (응답시간 단축을 위한 분산 OCSP 인증서 검증 모델)

  • Choi Seung kwon;Jang Yoon sik;Ji Hong il;Shin Seung soo;Cho Yong hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.304-311
    • /
    • 2005
  • OCSP has specific characters which can suspend, close, and correct in real time. But, as more clients use the OCSP server verification, more updated information is needed, which can lead to jamming in the OCSP server. To apply this technique of Distributed OCSP server so as to reduce the certificate verification OCSP from jamming. Also, the Distributed OCSP server will solve the problems of the intensive central structure. Simulation results show that the average reply time of certificate verification request and server load are reduced in the case using distributed OCSP. In addition to this advantage, resource distribution and fault tolerance are acquired because of multiple OCSP.

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.