Analysis of Lightning observed by KEPCO Lightning Detection Network (한전낙뢰관측 시스템 KLDNet의 낙뢰관측 결과 분석)

  • Kwak, J.S.;Park, M.H.;Jeong, M.J.;Ju, H.J.;Oh, S.Y.;Kim, H.S.;Woo, J.W.;Han, K.S.;Goo, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.398-399
    • /
    • 2015
  • The fault level of power transmission lines caused by natural disaster such as lightning and rainstorm has been on the rise. Especially, the cause of lightning stokes is large part of transmission faults. In order to reduce the lightning failures, it is necessary to measure and analyze the lightning characteristics. This paper deals with observation of the lightning strokes by KEPCO Lightning Detection Network(KLDNet) and analysis including lightning density, multiplicity and amplitude distribution.

  • PDF

A Comparative Study on the Risk(Individual and Societal) Assessment for Surrounding Areas of Chemical Processes (화학공정 주변지역에 미치는 위험성(사회적 위험성 및 개인적 위험성) 평가방법에 관한 비교 연구)

  • 김윤화;엄성인;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.1
    • /
    • pp.56-63
    • /
    • 1995
  • Two methods of the numerical method of CPQRA(Chemical Process Quantitative Risk Analysis) and the manual method of IAEA(International Atomic Energy Agency) were used to estimate the individual risk and societal risk around the chemical plant. Where, the CPQRA is introduced to verify the theoritical background of the manual of international atomic energy agency. The Gaussian plume model which has a weather stability class D with velocity of 5m/s was applied to calculate dispersion of hazard material. Also, 8-point method was employed to the effects of accidents for wind distribution. Furthermore, historical record, FTA(Fault Tree Analysis) and ETA(Event Tree Analysis) were used to estimate the probability or frequency of accidents. Eventually, the individual risk shows isorisk contour and the societal risk shows F-N curve around hazard facility, especially in chemical plants. Caulculated results, which both individual and societal risk, by using IAEA manual show simillar results to those of calculation by numerical method of CPQRA.

  • PDF

An Expert System for Fault Restoration in Distribution System (배전 계통에서의 사고 복구를 위한 전문가 시스템)

  • Choi, B.Y.;Kim, S.H.;Lee, Y.S.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.171-174
    • /
    • 1990
  • When load areas on a feeder are deenergized due to faults,operaters need to identify nelghboring feeders, try to restore customers and minimize out-of-service areas. These cases include knowledge of system states and various constraints such as voltage drop. This paper concerns the load transfer infault restoration. Also, it is considered the operating constraints such as line current capacity, relay trip current, transformer capacity, voltage drop and line loss. The expert system is able to propose the optimal load transfer method by anallzing system states and considering constraints.

  • PDF

Safety Analysis on the Tritium Release Accidents

  • Yang, Hee joong
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.2
    • /
    • pp.96-107
    • /
    • 1991
  • At the design stage of a plant, the plausible causes and pathways of release of hazardous materials are not clearly known. Thus there exist large amount of uncertainties on the consequences resulting from the operation of a fusion plant. In order to better handle such uncertain circumstances, we utilize the Probabilistic Risk Assessment(PRA) for the safety analyses on fusion power plant. In this paper, we concentrate on the tritium release accident. We develop a simple model that describes the process and flow of tritium, by which we figure out the locations of tritium inventory and their vulnerability. We construct event tree models that lead to various levels of tritium release from abnormal initiating events. Branch parameters on the event tree are assessed from the fault tree analysis. Based on the event tree models we construct influence diagram models which are more useful for the parameter updating and analysis. We briefly discuss the parameter updating scheme, and finally develop the methodology to obtain the predictive distribution of consequences resulting from the operating a fusion power plant. We also discuss the way to utilize the results of testing on sub-systems to reduce the uncertain ties on over all system.

  • PDF

Development of Ground and Short Test Equipment for Fault Analysis of Distribution Line (배전선의 고장해석을 위한 지락 및 단락 시험장치 개발)

  • 김응상;이재복
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.243-249
    • /
    • 2000
  • 대체에너지에 대한 연구가 활발히 진행됨에 따라 향후 배전계통은 신 에너지 전원 등과 같은 분산형 전원과 연계되어 네트워크 형식으로 구성될 것으로 예상된다. 이러한 배전계통의 변화는 지락 및 단락 사고 시 기존의 보호협조에 있어서 많은 문제점을 발생시킬 것이며, 이러한 배전계통의 변화와 전력 고품질 요구에 대응하기 위해서는 새로운 보호협조 체계가 필요하다. 새로운 보호협조 방식의 개발을 위해 필수적인 지락과 단락사고 시 배전계통의 사고 데이터는 실제 운영 도중에 얻기 어렵다. 본 논문에서는 기존 전원시스템 및 신 에너지 전원을 포함한 새로운 배전계통의 운용시 발생할 수 있는 사고 상황을 예측하고 고장 데이터를 수집하기 위해 저압 배전선로에 인위적으로 지락 및 단락을 발생시킬 수 있는 장치의 개발에 대해 서술한다. 개발한 시험장치의 기능을 확인하기 위하여 실제 배전계통에 적용하여 지락 및 단락 시험을 수행하여 전압 및 전류 파형을 측정·분석하여 시험장치의 신뢰성과, 효용성을 검증하였다.

  • PDF

Region Division for Large-scale Image Retrieval

  • Rao, Yunbo;Liu, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.10
    • /
    • pp.5197-5218
    • /
    • 2019
  • Large-scale retrieval algorithm is problem for visual analyses applications, along its research track. In this paper, we propose a high-efficiency region division-based image retrieve approaches, which fuse low-level local color histogram feature and texture feature. A novel image region division is proposed to roughly mimic the location distribution of image color and deal with the color histogram failing to describe spatial information. Furthermore, for optimizing our region division retrieval method, an image descriptor combining local color histogram and Gabor texture features with reduced feature dimensions are developed. Moreover, we propose an extended Canberra distance method for images similarity measure to increase the fault-tolerant ability of the whole large-scale image retrieval. Extensive experimental results on several benchmark image retrieval databases validate the superiority of the proposed approaches over many recently proposed color-histogram-based and texture-feature-based algorithms.

A Simulation of Lightning Faults Reducing Effects on the 154 kV Transmission Tower by Auxiliary Grounding (보조접지선 시공에 의한 송전선로의 내뢰성 향상효과 모의)

  • Kwak, Joo-Sik;Shim, Jeong-Woon;Shim, Eung-Bo;Choi, Jong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1843-1846
    • /
    • 1997
  • This paper describes the fault reducing effects of the 154 kV transmission tower by auxiliary grounding from the top of the tower to ground. The grounding surge impedance of the auxiliary grounding system is calculated by CDEGS(:Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis), and the critical lightning back flashover current and arcing horn dynamic characteristics are simulated by EMTP/TACS(:Electromagnetic Transient Program/Transient Analysis of Control Systems). The calculated results of total LFOR(Lightning Flashover Rate) shows that the LFOR can be reduced from 5.2(count/100km. year) to 3.4 by auxiliary grounding on the 154 kV transmission tower with one ground wire shielding system.

  • PDF

Workload Distribution and Performance Analysis Simulation for a Distributed Server Cluster System (분산 서버 클러스터 시스템의 부하 분산 및 성능 분석 시뮬레이션)

  • 최은미;이원규
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.4
    • /
    • pp.103-111
    • /
    • 2003
  • A distributed sewer cluster system is a cost-effective system to provide a service application for clients with reliable, scalable, available, and fault-tolerant features. In order to provide high quality services, it is necessary to evaluate service performances, tune the server system, and analyze performances. In this paper, we propose a simulator to generate workloads based on statistic configuration according to estimated application traffics, apply workload scheduling algorithms, and evaluate the simulation results. We introduce the simulator design modelling and architecture. By using flexible parameters, the simulator is able to generate various patterns of workloads with different statistics, and configure system environments such as the number of server nodes, system resources considered, and their capacities. With this simulator, we introduce two scenarios: one is to find appropriate thresholds for the best performance of cluster system, and the other is to find the suitable scheduling algorithm for workload characteristics of service applications.

  • PDF

Transient analysis of point defect dynamics in czochralski-grown silicon crystals

  • Wang, Jong-Hoe;Oh, Hyun-Jung;Park, Bong-Mo;Lee, Hong-Woo;Yoo, Hak-Do
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.6
    • /
    • pp.259-263
    • /
    • 2001
  • The continuum model of transient point defect dynamics to predict the concentrations of interstitial and vacancy is established by estimating expressions for the thermophysical properties of intrinsic point defects. And the point defect distribution in a Czochralski-grown 200 mm silicon crystal and the location of oxidation-induced stacking fault ring(OiSF-ring) created during the cooling of crystals are calculated by using the numerical analysis. The purpose of this paper is to show that his approach lead to predictions that are consistent with experimental results. Predicted point defect distributions by transient point defect dynamic analysis are in good qualitative agreement with experimental data under widely and abruptly varying crystal pull rates when correlated with the position of the OiSF-ring .

  • PDF

Improved Evaluation Method of Flicker considering Disturbances of Power System

  • Kim, Jae-Chul;Moon, Jong-Fil;Jung, Seung-Bock;Choe, Kyu-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.8-14
    • /
    • 2008
  • This paper studies a more exact flicker evaluation method by detecting power quality disturbances and excluding the effects of power quality disturbances. Up to the present, power quality disturbances affect flicker evaluation index because power quality problems do not have been considered. However, flick index should represent only flicker without power quality disturbances. Thus, in this paper, we present the improved flicker evaluation method which removing the effects of power quality disturbances such as voltage sag and transient caused by fault and inverter/breaker switching. We detect voltage sag and transient using wavelet transform and remove the effects of power quality disturbances from flicker index.