• Title/Summary/Keyword: Distribution Fault

Search Result 1,024, Processing Time 0.032 seconds

Study of Drawing Optimum Switch Automation Rate to Minimize Reliability Cost (신뢰도 비용 최소화를 위한 개폐기의 최적 자동화율 도출에 관한 연구)

  • Chai, Hui-seok;Kang, Byoung-wook;Kim, Jin-seok;Moon, Jong-fil;Kim, Jae-chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.297-302
    • /
    • 2015
  • Replacing a manual switch installed in a feeder for a distribution system with an automatic one increases the reliability of the electric power system. This is because the automatic switch can shorten the duration of a fault the customer experiences by splitting the faulty section faster than the manual one does. However, improving the reliability of the distribution system may increase investment costs. Here, the investment costs include automatic switch cost, replacement work cost and labor cost. For this reason, importance should be attached to the proper balance between the increase of the investment costs and the improvement of the reliability of the distribution system. This article analyzed reliability index and economics when manual switches installed in a feeder (RBTS Bus2 model) was replaced by automatic ones. In addition, it attempted to draw the optimum rate of automation of manual switches by automatic ones using the GRG optimization method, considering the current economic requirements.

Development of Enhanced Real-Time Service Restoration Algorithm for Distribution Automation System (실 배전계통 자동화를 위한 개선된 고장복구 알고리즘 개발)

  • Oh, H.J.;Mun, K.J.;Kim, H.S.;Seo, J.I.;Hwang, G.H.;Park, J.H.;Lim, S.I.;Ha, B.N.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.159-161
    • /
    • 2000
  • This paper presents a GA for service restoration in electric power distribution systems. The aim of the service restoration is to restore service with maximizing the amount of total load restored while minimizing the number of required switch operation when a fault or overload occurs in distribution system. This paper develops GA for service restoration problem with constrained multi-objective optimization problem. The results show the effectiveness of the proposed method for solving the problem.

  • PDF

Design of Leakage Current Detecting Equipment of an Arrester Diagnostic Type in a Distribution Line (배전선로용 피뢰기 진단형 누설전류 검출장치 설계)

  • Yoon, Gi-Gab;Park, Jong-Beom;Yoon, Suk-Mu;Lee, Seung-Hak;Kim, Hong-Pil;Kim, Kwang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.501-503
    • /
    • 2000
  • Since an arrester has been generally used at the distribution line and abroad for the protection of electrical equipments against overvoltage (or abnormal surge) taking place in or from an electrical system, a fault, especially, in the distribution line is very likely to result in the destruction of insulation of other protection devices to cause an overall paralysis of a power system, a chaos. Considering the importance of arresters, its earlier replacement than its proposed life cycle causes an economical loss, and a negligence not to replace or repair it in time gives rise to a crucial accidence. The purpose of this paper is to invent an electric leakage current detector and to solve such problems by the continuous and regular inspection of an arrester.

  • PDF

Quantification of Entire Change of Distributions Based on Normalized Metric Distance for Use in PSAs

  • Han, Seok-Jung;Chun, Moon-Hyun;Tak, Nam-Il
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.270-282
    • /
    • 2001
  • A simple measure of uncertainty importance based on normalized metric distance to quantify the entire change of cumulative distribution functions (CDFs) has been developed for use in probability safety assessments (PSAs). The metric distance measure developed in this study reflects the relative impact of distributional changes of inputs on the change of an output distribution, white most of the existing uncertainty importance measures reflect the magnitude of relative contribution of input uncertainties to the output uncertainty. Normalization is made to make the metric distance measure a dimensionless quantity. The present measure has been evaluated analytically for various analytical distributions to examine its characteristics. To illustrate the applicability and strength of the present measure, two examples are provided. The first example is an application of the present measure to a typical problem of a system fault tree analysis and the second one is for a hypothetical non-linear model. Comparisons of the present result with those obtained by existing uncertainty importance measures show that the metric distance measure is a useful tool to express the measure of uncertainty importance in terms of the relative impact of distributional changes of inputs on the change of an output distribution.

  • PDF

The Comparative Study for NHPP Software Reliability Growth Model Based on Non-linear Intensity Function (비선형 강도함수를 가진 NHPP 소프트웨어 신뢰성장 모형에 관한 비교 연구)

  • Kim, Hee-Cheul
    • Convergence Security Journal
    • /
    • v.7 no.2
    • /
    • pp.1-8
    • /
    • 2007
  • Finite failure NHPP models presented in the literature exhibit either constant, monotonic increasing or monotonic decreasing failure occurrence rates per fault (intensity function). In this paper, intensity function of Goel-Okumoto model was reviewed, proposes Kappa (2) and the Burr distribution, which maked out efficiency application for software reliability. Algorithm to estimate the parameters used to maximum likelihood estimator and bisection method. For model determination and selection, explored goodness of fit (the error sum of squares) The methodology developed in this paper is exemplified with a software reliability real data set introduced by NTDS (Naval Tactical Data System)

  • PDF

An Optimal Peer Selection Algorithm for Mesh-based Peer-to-Peer Networks

  • Han, Seung Chul;Nam, Ki Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.133-151
    • /
    • 2019
  • In order to achieve faster content distribution speed and stronger fault tolerance, a P2P peer can connect to multiple peers in parallel and receive chunks of the data simultaneously. A critical issue in this environment is selecting a set of nodes participating in swarming sessions. Previous related researches only focus on performance metrics, such as downloading time or the round-trip time, but in this paper, we consider a new performance metric which is closely related to the network and propose a peer selection algorithm that produces the set of peers generating optimal worst link stress. We prove that the optimal algorithm is practicable and has the advantages with the experiments on PlanetLab. The algorithm optimizes the congestion level of the bottleneck link. It means the algorithm can maximize the affordable throughput. Second, the network load is well balanced. A balanced network improves the utilization of resources and leads to the fast content distribution. We also notice that if every client follows our algorithm in selecting peers, the probability is high that all sessions could benefit. We expect that the algorithm in this paper can be used complementary to existing methods to derive new and valuable insights in peer-to-peer networking.

Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders (태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구)

  • Kim, Byungki;Kim, Sohee;Ryu, Kyungsang;Rho, Daeseok
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.4
    • /
    • pp.29-37
    • /
    • 2011
  • Dispersed generation (DG) such as wind power (WP) and Photovoltaic systems (PV) that has been promoted at the national level recently is mainly being introduced into distribution systems adjacent to consumers because it is generation on a small scale when compared to current generation. Due to its characteristics, DG can be operated by interconnection with distribution systems to present security of more stable power and efficient use of power facilities and resources. Problems on protection coordination of distribution systems by reverse flow of DG can roughly be divided into three possibilities: excess in rated breaking capacity (12.5KA) of protective devices by a fault in DG current supply, failure to operate protective devices by an apparent effect that can occur by reduction in impedance parallel circuit fault current due to interconnection of DG, and malfunction of protective devices by interconnection transformer connection type. The purpose of this study is to analyze problems in protection coordination that can occur when DG is operated by interconnection with distribution systems by conducting modeling and simulations by using theoretical symmetrical components and MATLAB/SIMULINK to present methods to improve such problems.

Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System (대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘)

  • Kwon, Soon-hwan;Lee, Hu-dong;Nam, Yang-hyun;Rho, Dae-seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.17-26
    • /
    • 2018
  • If a photovoltaic (PV) system is installed in a primary feeder interconnected with the PV system, bi-directional power flow can occur, and then, the magnitude and direction of the fault current can change, depending on the fault location and point of common coupling (PCC) of the PV system, and the time current curve (TCC) cannot be properly coordinated between protection devices. Also, it is difficult to obtain a proper time interval for protection devices because the conventional setting approach is applied, even though the PV system is installed and operating. Therefore, this paper presents three operation modes considering the operational conditions of the PV system to obtain setting values for protection devices. Based on the mode, this paper proposes an algorithm to calculate the optimal protection coordination time interval according to the introduction capacity of the PV system. In addition, this paper performs modelling of a distribution system with the PV system and protection devices by using Off-DAS S/W, and analyzes the characteristics of the time interval between the protection devices, such as substation relays, reclosers, customer relays, and PV customer relays. The simulation results confirmed that the proposed operational modes and setting-value algorithms are useful and effective for protection coordination in a distribution system for a PV system.

Classification of Shear Strength according to Breccia Content in Fault Core (단층각력 함량에 따른 전단강도의 분류)

  • Yun, Hyun-Seok;Moon, Seong-Woo;Seo, Yong-Seok
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.167-181
    • /
    • 2020
  • Analysis of variance (ANOVA) and multiple comparison analysis were performed for shear strengths categorized by breccia content of 5 wt.% (Case-I), 10 wt.%, (Case-II) and 15 wt.% (Case-III) in fault cores. The relationship between breccia contetnt and shear strength was quantitatively classified by calculating the mean and standard deviation of shear strength for each population in each case and then the grouping the breccia contents that had a statistically similar effect on the dispersion of shear strength. As a result, shear strength was clearly classified into group 1 (breccia content of 0-15 wt.%) and group 2 and 3 (breccia coantent of 15-30 wt.% and 30 wt.% or more) in Case-III. Shear strength of the standard line at breccia content of 15 wt.% were determined to be 43.6 kPa, 77.6 kPa, and 118.6 kPa at each normal stress (54 kPa, 108 kPa, and 162 kPa), respectively. In addition, the distribution range of cohesions is 0-43.6 kPa at breccia content of 15 wt.% or less, and 0-70.0 kPa at 15 wt.% or more. Distribution range of friction angles is 0-45.7 ° at breccia content of 15 wt.% or less, and 16.7-57.5 ° at 15 wt.% or more.

Quantification of rock deformation using wavy extinction of quartz grain (석영의 파동소광 강도를 이용한 암석 변형의 정량화)

  • 정원석;나기창;정상원
    • The Journal of the Petrological Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.65-73
    • /
    • 2002
  • The wavy extinction of quartz grains can be used as a good indicator to show the degree of rock deformation. To determine degree of the rock deformation, intensity of wavy extinction (IWE) of quartz grains was measured by using polarizing microscope, digital camera, and NIH image (or Scion Image). In this experiment, the measurement was performed along the line perpendicular to the subgrain boundary of wavy extinction. IWE was measured when a quartz grain shows maximum extinction in polarizing microscope. NIH image was represented in terms of 256 gray-scale brightness, which was associated with intensity of the wavy extinction. IWE was determined by the degree of brightness versus the measuring length of a quartz grain. IWE was analysed in the distribution chart with the collection unit of 5. Regarding the characteristics of data distribution, the median between the mode and the median of the histogram is defined as a representative value for the IWE, and this value is subdivided into the five levels of rock deformation zones (lowest- or non-, low-, medium-, high-, and highest deformation) with their respective indices (D1, D2, D3, D4, and D5). The correlation between the Eonyang Granite and the Yangsan Fault was investigated by using the indices. The results indicate that IWE values decreased away from the fault.