• Title/Summary/Keyword: Distribution Department

Search Result 23,866, Processing Time 0.048 seconds

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

Retrieval of background surface reflectance with pre-running BRD components

  • Choi, Sungwon;Lee, Chang Suk;Seo, Minji;Seong, Noh-hun;Lee, Kyeong-Sang;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • Importance of remote sensing for surface is increased than past. So many countries try to many ways to retrieve surface reflectance. In this study, we study a Bidirectional Reflectance Distribution Function (BRDF) to retrieve surface reflectance. We apply BRDF using observed surface reflectance of SPOT/VEGETATION (VGT-S1) and angular data to get Bidirectional Reflectance Distribution (BRD) coefficients for calculating scattering. And then we apply BRDF in the opposite direction with BRD coefficients and angular data to retrieve Background Surface Reflectance (BSR). The range of BSR is not over $0.4{\mu}m$ (blue), $0.45{\mu}m$ (red), $0.55{\mu}m$ (NIR). And for validation we compare BSR with VGT-S1, there are bias is from 0.0116 to 0.0158 and RMSE is from 0.0459 to 0.0545. As a result, we confirm that BSR is similar to VGT-S1.

Evaluation of Molecular Weight Distribution, Pasting and Functional Properties, and Enzyme Resistant Starch Content of Acid-modified Corn Starches

  • Koksel, Hamit;Ozturk, Serpil;Kahraman, Kevser;Basman, Arzu;Ozbas, Ozen Ozboy;Ryu, Gi-Hyung
    • Food Science and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.755-760
    • /
    • 2008
  • The aim of this study was to produce resistant starch preparations from acid-modified com starches prepared at various hydrolysis levels (0.5-4.0 hr). Effect of autoclaving cycles on resistant starch (RS) formation was investigated. Molecular weight distribution, pasting and functional properties of acid-modified com starches were determined. For RS formation native and acid-modified starch samples were gelatinized and autoclaved (1 or 2 cycles). While native and acid-modified starches did not contain any RS, the levels increased to 9.0-13.5% as a result of storage at $95^{\circ}C$ after first autoclaving cycle. Second autoclaving cycle together with storage at $95^{\circ}C$ brought final RS contents of the samples incubated at 4 and $95^{\circ}C$ after the first cycle to comparable level. As acid modification level increased, the amount of high molecular weight fractions decreased, resulting in significant decreases in viscosities (p<0.05). The samples produced in this study had low emulsion stability and capacity values.

Effect of Temperature on Propylene Aromatization over MFI Type Zeolites (Propylene Aromatization에 미치는 온도 및 촉매의 영향)

  • Park, Jin-U;Kim, Sang-Bum;Kwak, Yun-Cheol;Shin, Ki-Seok;Park, Hong-Soo;Hahm, Hyun-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.123-130
    • /
    • 2002
  • [Ga]-MFI and H-ZSM-5 catalysts were synthesized under atmospheric pressure and used in the propylene aromatization. The effect of temperature on the product distribution was also investigated. The catalytic activities of the prepared catalysts were compared with the commercialized H-ZSM-5 which was converted from $NH_{4}$-ZSM-5. In the propylene aromatization, product distribution does not depend on the ratio of Si/$Ga_{2}$ with [Ga]-MFI catalyst, but depend on the ratio of Si/$Al_{2}$ with H-ZSM-5 catalyst [Ga]-MFI catalyst shows better dehydrogenation and alkylation activities than H-ZSM-5 catalyst The addition of Ga to H-ZSM-5 catalyst increases the conversion of propylene, selectivity to aromatics, and alkylation. In the propylene aromatization, the selectivity to aromatics slightly increased with increasing temperature with [Ga]-MFI catalyst, while slightly decreased with increasing temperature with H-ZSM-5 catalyst.

Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures (내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구)

  • Kim, Ji-Hun;Yoon, Sangwoo;Kwon, Sung-Ho;Sung, Su-Hwan;Bae, Mun-Oh;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

Feasibility to Expand Complex Wards for Efficient Hospital Management and Quality Improvement

  • CHOI, Eun-Mee;JUNG, Yong-Sik;KWON, Lee-Seung;KO, Sang-Kyun;LEE, Jae-Young;KIM, Myeong-Jong
    • The Journal of Industrial Distribution & Business
    • /
    • v.11 no.12
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: This study aims to explore the feasibility of expanding complex wards to provide efficient hospital management and high-quality medical services to local residents of Gangneung Medical Center (GMC). Research Design, Data and Methodology: There are four research designs to achieve the research objectives. We analyzed Big Data for 3 months on Social Network Services (SNS). A questionnaire survey conducted on 219 patients visiting the GMC. Surveys of 20 employees of the GMC applied. The feasibility to expand the GMC ward measured through Focus Group Interview by 12 internal and external experts. Data analysis methods derived from various surveys applied with data mining technique, frequency analysis, and Importance-Performance Analysis methods, and IBM SPSS statistical package program applied for data processing. Results: In the result of the big data analysis, the GMC's recognition on SNS is high. 95.9% of the residents and 100.0% of the employees required the need for the complex ward extension. In the analysis of expert opinion, in the future functions of GMC, specialized care (△3.3) and public medicine (△1.4) increased significantly. Conclusion: GMC's complex ward extension is an urgent and indispensable project to provide efficient hospital management and service quality.

Mechanical properties of reinforced-concrete rocking columns based on damage resistance

  • Zhu, Chunyang;Cui, Yanqing;Sun, Li;Du, Shiwei;Wang, Xinhui;Yu, Haochuan
    • Structural Engineering and Mechanics
    • /
    • v.80 no.6
    • /
    • pp.737-747
    • /
    • 2021
  • The objective of seismic resilience is to maintain or rapidly restore the function of a building after an earthquake. An efficient tilt mechanism at the member level is crucial for the restoration of the main structure function; however, the damage resistance of the members should be the main focus. In this study, through a comparison with the classical Flamant theory of local loading in the elastic half-space, an elastomechanical solution for the axial-stress distribution of a reinforced-concrete (RC) rocking column was derived. Furthermore, assuming that the lateral displacement of the rocking column is determined by the contact surface rotation angle of the column end and bending and shear deformation of the column body, the load-lateral displacement mechanical model of the RC rocking column was established and validated through a comparison with finite-element simulation results. The axial-compression ratio and column-end strength were analyzed, and the results indicated that on the premise of column damage resistance, simply increasing the axial-compression ratio increases the lateral loading capacity of the column but is ineffective for improving the lateral-displacement capacity. The lateral loading and displacement of the column are significantly improved as the strength of the column end material increases. Therefore, it is feasible to improve the working performance of RC rocking columns via local reinforcement of the column end.

Structural performance of an electricity tower under extreme loading using the applied element method- A case study

  • Chin, Jason Ah;Garcia, Mauricio;Cote, Jeffrey;Mulcahy, Ellen;Clarke, Jonathan;Elshaer, Ahmed
    • Wind and Structures
    • /
    • v.34 no.3
    • /
    • pp.313-319
    • /
    • 2022
  • The resiliency of electricity transmission and distribution lines towards natural and man-made hazards is critical to the operation of cities and businesses. The extension of these lines throughout the country increases their risk of extreme loading conditions. This paper investigates a unique extreme loading condition of a 100-year old distribution line segment that passes across a river and got entangled with a boom of a ship. The study adopts the Applied Elements Method (AEM) for simulating 54 cases of the highly deformable structural behaviour of the tower. The most significant effects on the tower's structural integrity were found to occur when applying the load with components in all three of the cartesian directions (i.e., X, Y and Z) with the full capacities of the four cables. The studied extreme loading condition was determined to be within the tower's structural capacity, attributed to the shear failure of the anchor bolts, which acted as a sacrificing element that fails to protect the transfer of tensioning load to the supporting tower.

On-the-fly energy release per fission model in STREAM with explicit neutron and photon heating

  • Nhan Nguyen Trong Mai;Woonghee Lee;Kyeongwon Kim;Bamidele Ebiwonjumi;Wonkyeong Kim;Deokjung Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1071-1083
    • /
    • 2023
  • The on-the-fly energy release per fission (OTFK) model is implemented in STREAM to continuously update the Kappa values during the depletion calculation. The explicit neutron and photon energy distribution, which has not been considered in previous STREAM versions, is incorporated into the existing on-the-fly model. The impacts of the modified OTFK model with explicit neutron and photon heating in STREAM on the power distribution, fuel temperature, and other core parameters during depletion with feedback calculations are studied using several problems from the VERA benchmark suit. Overall, the explicit heating calculation provides a better power map for the feedback calculations particularly when strong gamma emitters are present. Generally, the fuel temperature decreases when neutron and photon heating is employed because fission neutrons and gamma rays are transported away from their points of generation. This energy release model in STREAM indicates that gamma energy accounts for approximately 9.5%-10% of the total energy released, and approximately 2.4%-2.6% of the total energy released will be deposited in the coolant for the VERA 5, NuScale, and Yonggwang Unit 3 2D cores.

Cytomegalovirus Pneumonia: High-Resolution CT Findings in Ten Non-AIDS Immunocompromised Patients

  • Jeung Hee Moon;Eun A Kim;Kyung Soo Lee;Tae Sung Kim;Kyung-Jae Jung;Jae-Hoon Song
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.73-78
    • /
    • 2000
  • Objective: To describe the HRCT findings of cytomegalovirus (CMV) pneumonia in non-AIDS immunocompromised patients Materials and Methods: This retrospective study involved the ten all non-AIDS immunocompromised patients with biopsy-proven CMV pneumonia and without other pulmonary infection encountered at our Medical Center between January 1997 and May 1999. HRCT scans were retrospectively analysed by two chest radiologists and decisions regarding the findings were reached by consensus. Results: The most frequent CT pattern was ground-glass opacity, seen in all patients, with bilateral patchy (n = 8) and diffuse (n = 2) distribution. Other findings included poorly-defined small nodules (n = 9) and consolidation (n = 7). There was no zonal predominance. The small nodules, bilateral in eight cases and unilateral in one, were all located in the centrilobular region. Consolidation (n = 7), with patchy distribution, was bilateral in five of seven patients (71%). Pleural effusion and bilateral areas of thickened interlobular septa were seen in six patients (60%). Conclusion: CMV pneumonia in non-AIDS immunocompromised patients appears on HRCT scans as bilateral mixed areas of ground-glass opacity, poorly-defined centrilobular small nodules, and consolidation. Interlobular septal thickening and pleural effusion are frequently associated.

  • PDF