• Title/Summary/Keyword: Distribution Department

Search Result 23,866, Processing Time 0.05 seconds

Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study (네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석)

  • Jeon, Sang-Je;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.359-370
    • /
    • 2006
  • The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis (3D FEA). The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. Four different lesion configurations representative of the various types observed clinically for teeth were studied. A static point load of 500N was applied to the buccal and lingual cusp (Load A and B). The principal stresses in lesion apex, and vertical sectioned margin of cervical wall were analyzed. The results were as follows 1. The patterns of stress distribution were similar but the magnitude was different in four types of lesion 2. The peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 3. The compressive stress under load A and the tensile stress under load B were dominant stress. 4. Under the load, lesion can be increased and harmful to tooth structure unless restored.

The Distribution of $^{14}C-chitosan$ by Different Molecular Weight in Mice (마우스에서 $^{14}C-chitosan$ 분자량별 체내 분포에 관한 연구)

  • Kim, Kwang-Yoon;Kim, Young-Ho;Kim, Hee-Kyung;Bom, Hee-Seung;Kim, Ji-Yeul;Roh, Young-Bok;Nishimura, Yoshikazu
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.83-88
    • /
    • 1998
  • Chitosan is a nontoxic natural chealtor which was made by chitin, and reduced a contamination of radiostrontium in animals. In this experiment, A different molecular weight of C-14 chitosan was intravenously administered to mice, and then the distribution of C-14 chitosan in the body was observed. Male mice (8 to 10 weeks, body weight of 30 to 35g) of ICR strain were used. C-14 chitosan was diluted with saline and then given intravenously in mice. After the administration of C-14 chitosan, mice was sacrificed at the 6th hour, 1st, 3rd, 5th, and 7th day. Beta radioactivities in the blood, liver, kidney, liver, muscle, testis, and urine was measured using a liquid scintillation analyzer. Most of the C-14 chitosan was excreted through urine within 6 hours. Biodistribution of C-14 chitosan was similar despite the difference of moleclar weight. Higher distributions of radioactivities were found in the liver, kidney, spleen. The relative concentration in tissue increased for the 6 hours and then decreased. In conclusion, most of C-14 chitosan was excreted through urine despite the difference of molecular weight. and, low molecular weight of C-14 chitosan showed higher distribution than high molecular weight of C-14 chitosan in tissues.

  • PDF

Strategic Approaches to Solid Ranking International Journals: KODISA Journals (국제저널 육성 방향과 전망: KODISA Journals를 중심으로)

  • Youn, Myoung-Kil;Kim, Dong-Ho;Lee, Jong-Ho;Hwang, Hee-Joong;Lee, Jung-Wan
    • Journal of Distribution Science
    • /
    • v.12 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Purpose - The purposes of this editorial review are twofold: firstly, to introduce the four flagship international journals of the Korea Distribution Science Association(KODISA): the Journal of Distribution Science(JDS), the Journal of Industrial Distribution & Business(JIDB), the East Asian Journal of Business Management(EAJBM), and the Journal of Asian Finance, Economics and Business(JAFEB), and secondly, to identify the direction of the KODISA journals and the roles and responsibilities of the editors of the KODISA journals. Research design, data, and methodology - To achieve the goals, firstly, this review paper addresses the current progress of the four KODISA journals: JDS, JIDB, EAJBM, and JAFEB. Secondly, this paper defines the aims and missions of the four KODISA journals. JDS publishes the articles of examining past, current, and emerging trends and concerns in the area of distribution science and economics, logistics and SCM, transportation, distribution channel management, distribution innovation and information technology, merchandising and procurement, distribution and marketing, consumer behavior, and manufacturing, wholesaling, and retailing. JDS publishes both quantitative and qualitative research as well as scholarly commentaries, case studies, book reviews and other types of reports relating to all aspects of distribution. JIDB publishes the articles of examining past, current, and emerging trends and concerns in the areas of industry and corporate behavior, industry policy making, industrial distribution and business, e-commerce, and service industry. EAJBM publishes empirical and theoretical research papers as well as scholarly commentaries, case studies, book reviews, and other types of reports relating to all aspects of East Asian business and economy. JAFEB publishes original research analysis and inquiry into the contemporary issues of finance, economics and business management in Asia, including Central Asia, East Asia, South Asia, Southeast Asia, and Middle East. The mission of JAFEB is to bring together the latest theoretical and empirical finance, economics and business management research in Asian markets. The audiences of the KODISA journals include higher education institutions, scholars, industry researchers and practitioners, scientists, economists, and policy makers throughout the world. The main mission of the KODISA journals is to provide an intellectual platform for international scholars, promote interdisciplinary studies in social sciences and economics, and become leading journals in the social science and economics category in the world. Thirdly, this paper addresses the current status of indexing in major databases of the KODISA journals, namely: Cabell's Directories, EBSCO, SCOPUS (Elsevier), and Social Sciences Citation Index® (SSCI, Thomson Reuters). Fourthly, this paper identifies the roles and responsibilities of the editors of the KODISA journals as the following: (1) Make sure that the journal be published in a timely manner and in international standards both in print and online versions. (2) Maintain the online homepage of the journal is always accessible to, and (3) Make sure that every article should go through a peer review process that meets international standards. Findings and conclusion - To accomplish the goals and missions of the KODISA journals, the editors of the KODISA journals must work together to publish high scholarly journals that meet international standards of journal publications.

Measurement of Space Dose Distribution during Exposure Micro Computed Tomography (μ-CT) for Scattering Rays (Micro-CT 촬영 시 발생되는 산란선에 관한 공간선량률 측정)

  • Jung, Hongmoon;Won, Doyeon;Kwon, Taegeon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Non-invasive technique CT, called automated computed tomography, is used to detect lesion of a patient when diagnosing human body. Information obtained from CT plays an important role in assembling 3 dimensional images. Recently, new equipment, operated by CT, is required which can be appliable to physical and biological research. In accordance to this quest, micro-CT is invented that produce more detail and concrete information. Images supplied by CT are even more detailed and concrete, so it contributes much to the development of biology and polymer material engineering field. However, there has been little reliable reports regarding measuring information of space dose distribution about exposure dose limit of users operating micro-CT. In addition, little reports regarding space dose distribution of exposure has been known about unwanted diffraction light produced by usage of micro-CT. The exterior of micro-CT is covered by lead, which is for removing exposure of diffraction light. Thus, even if it is good enough to prevent exposure of diffraction light, consistent management of equipment will be required as time goes by and equipment are getting old as well. We measured space dose distribution regarding exposure of diffraction light of users operating micro-CT directly. Therefore, we suggest that proper management should be necessary for users operating micro-CT not to be exposed by unwanted diffraction light.

INFLUENCE OF IMPLANT-ABUTMENT INTERFACE DESIGN, IMPLANT DIAMETER AND PROSTHETIC TABLE WIDTH ON STRENGTH OF IMPLANT-ABUTMENT INTERFACE : THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (임플랜트의 지대주 연결방식, 임플랜트의 직경 및 지대주 연결부위의 직경 차이에 따른 응력분포에 관한 삼차원 유한요소분석)

  • Oh Se-Woong;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.393-404
    • /
    • 2003
  • Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter and prosthetic table width to improve joint stability. In another part of this research, internal conical type implant-abutment interface was developed and reported joint strength is higher than traditional external hex interface. Purpose. The purpose of this study is to compare stress distribution in single molar implant between external hex butt joint implant and internal conical joint implant when increasing the implant diameter and prosthetic table width : 4mm diameter, 5mm diameter, 5mm diameter/6mm prosthetic table width. Material and method. Non-linear finite element models were created and the 3-dimensional finite element analysis was performed to see the distribution of stress when 300N static loading was applied to model at $0^{\circ},\;15^{\circ},\;30^{\circ}$ off-axis angle. Results. The following results were obtained : 1. Internal conical joint showed lower tensile stress value than that of external hex butt joint. 2. When off-axis loading was applied, internal conical joint showed more effective stress distribution than external hex butt joint. 3. External hex butt joint showed lower tensile stress value when the implant diameter was increased. 4. Internal conical joint showed lower tensile stress value than external hex butt joint when the implant diameter was increased. 5. Both of these joint mechanism showed lower tensile stress value when the prosthetic table width was increased. Conclusion. Internal conical joint showed more effective stress distribution than external hex joint. Increasing implant diameter showed more effective stress distribution than increasing prosthetic table width.

Analysis and Distribution of Polycyclic Aromatic Hydrocarbons and Chlorophenols in Sewage and Industrial Wastewater Sludge in Korea (국내 하.폐수슬러지 중 다환방향족탄화수소 및 염화페놀류의 분포 특성)

  • Ju, Joon-Hyung;Kim, Min-Young;Lee, Sung-Hee;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.735-742
    • /
    • 2008
  • In order to evaluate the levels and distribution patterns, the concentrations of PAHs and chlorophenols were investigated in sludge samples discharged from 6 WWTPs located along Nak-dong river and 7 STPs in Busan, Korea. Levels of 16 PAHs and 19 chlorophenols in sludge samples ranged from 1.28 to 44.9 mg/kg dry wt. and from 213 to 3,850 $\mu$g/kg dry wt., respectively. Levels of PAHs in sludge samples except I5 and S4 were detected lower than those of previous studies. The distribution patterns of PAHs and chlorophenols varied with industrial wastewater sludge samples because industrial wastewater sludge had different industrial input sources. However, the distribution patterns of PAHs and chlorophenols in sewage sludge were pretty similar. Phenanthrene, fluoranthene and pyrene were dominant and the fractions of these 3 PAHs relative to 16 PAHs in sewage sludge ranged from 30.8 to 50.7%. 2-chlorophenol is dominated in most sewage sludge samples and the fraction ranged from 36.0 to 66.8%.

Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy (세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성)

  • Kang, Min-Kyu;Kim, Sung-Joon;Shin, Hyun-Soo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.218-222
    • /
    • 2010
  • As radiation is irradiated from various directions in intensity modulated radiation therapy (IMRT), longer treatment time than conventional treatment method is taken. In case of the patients who have problem to keep same posture for long time because of pain and injury, reducing treatment time through increased dose rate is a way for effective treatment. This study measured and found out the variation of dose and dose distribution in accordance with dose rate variation. IMRT treatment plan was set up to investigate from 5 directions - $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ - using ECLIPSE system (Varian, SomaVision 6.5, USA). To confirm dose and dose rate in accordance with dose rate variation, dose rate was set up as 100, 300, 500 MU/min, and dose and dose distribution were measured using ionization chamber (PTW, TN31014) and film dosimeter (EDR2, Kodak). At this time, film dosimeter was inserted into acrylic phantom, then installed to run parallel with beam's irradiating direction, 21EX-S (Varian, USA) was utilized as linear accelerator for irradiation. The measured film dosimeter was analyzed using VXR-16 (Vidar System Corporation) to confirm dose distribution.

Estimation of mean annual extreme minimum temperature raster and predicting the potential distribution for Ipomoea triloba using Proto3 model in the Korean peninsula (격자형 한반도 최저극값온도 예측 및 Proto3를 활용한 별나팔꽃 (Ipomoea triloba)의 서식적합지 예측)

  • Lee, Yong Ho;Choi, Tae Yang;Lee, Ga Eun;Na, Chea Sun;Hong, Sun Hee;Lee, Do-Hun;Oh, Young Ju
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.759-768
    • /
    • 2019
  • This study was conducted to estimate the mean annual extreme minimum temperature raster and predict the potential distribution of the invasive plant, Ipomoea triloba, on the Korean peninsula. We collected annual extreme minimum temperature and mean coldest month minimum temperature data from 129 weather stations on the Korean peninsula from 1990-2019 and used this data to create a linear regression model. The min temperature of the coldest month raster from Worldclim V2 were used to estimate a 30 second spatial resolution, mean annual extreme minimum temperature raster of the Korean peninsula using a regression model. We created three climatic rasters of the Korean peninsula for use with the Proto3 species distribution model and input the estimated mean annual extreme minimum temperature raster, a Köppen-Geiger climate class raster from Beck et al. (2018), and we also used the mean annual precipitation from Worldclim V2. The potential distribution of I. triloba was estimated using the Proto3 model with 117 occurrence points. As a result, the estimated area for a potential distribution of I. triloba was found to be 50.7% (111,969 ㎢) of the Korean peninsula.

A photoelastic evaluation of stress distribution during distal movement of upper molar (헤드기어를 이용한 상악 제1대구치의 후방이동 시 응력분포에 관한 광탄성법적 연구)

  • Song, Sae-Eun;Lim, Sung-Hoon;Yoon, Young-Joon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.121-129
    • /
    • 2004
  • The purpose of this study was to photoelastically visualize 4he distribution of fortes transmitted to the alveolus and surrounding structures using three different types of headgear for the distal movement of the upper molars. A photoelastic maxillary model was made and three different directional forces applied, which were high-pull, straight-pull, and cervical-pull. Stress distribution was recorded through circular polariscope, and two-dimensional photoelastic stress analysis was performed according to isochromatic fringe characteristics. The results were as follows: 1. In the case of high-pull headgear bodily movement occurred in the medium- length outer bow, stress distribution in the apical region was 1st molar, 2nd premolar, lst premolar in sequence and there was no apparent difference. 2. In the case of straight-pull headgear, bodily movement occurred in the long outer bow and stress distribution in the apical region was heavy in the 1st molar, 2nd premolar, 1st premolar in sequence. But. there were no apparent differences according to the length of the outer bow. 3. In the case of cervical- pull headgear, bodily movement also occulted in 4he long outer bow, and apical stress of the premolar region was heaviest among other cases and apical stress of the 2nd premolar was heaviest in the short outer bow. In clinical situations, to achieve bodily movement of the upper 1st molars without modifying outer bow height, applying an outer bow length as long as the inner bow length in high-pull headgear and applying an outer bow length longer than the inner bow length in straight-pull, cervical-pull headgear are recommended.

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.