• Title/Summary/Keyword: Distribution Department

Search Result 23,866, Processing Time 0.067 seconds

MRI Findings of Triple Negative Breast Cancer: A Comparison with Non-Triple Negative Breast Cancer (삼중음성 유방암의 자기공명영상 소견: 비삼중음성 유방암과의 비교)

  • Choi, Jae-Jeong;Kim, Sung-Hun;Cha, Eun-Suk;Kang, Bong-Joo;Lee, Ji-Hye;Lee, So-Yeon;Jeong, Seung-Hee;Yim, Hyeon-Woo;Song, Byung-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.95-102
    • /
    • 2010
  • Purpose : To evaluate the magnetic resonance imaging (MRI) and clinicopathological features of triple negative breast cancer, and compare them with those of non-triple negative breast cancer. Materials and Methods : This study included 231 pathologically confirmed breast cancers from January 2007 to May 2008. We retrospectively reviewed the MRI findings according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon: mass or non-mass type, mass shape, mass margin, non-mass distribution, and enhancement pattern. Histologic type, histologic grade, and the results for epidermal growth factor receptor, p53, and Ki 67 were reviewed. Results : Of 231 patients, 43(18.6%) were triple negative breast cancer. Forty triple negative breast cancers (93.0%) were mass-type lesion on MRI. A round or oval or lobular shape (p=0.006) and rim enhancement (p=0.004) were significantly more in triple negative breast cancer than non- triple negative breast cancer. In contrast, irregular shape (p=0.006) and spiculated margins (p=0.032) were significantly more in non-triple negative breast cancer. Old age (p=0.019), high histologic grade (p<0.0001), EGFR positivity (p<0.0001), p53 overexpression (p=0.038), and Ki 67 expression (<0.0001) were significantly associated with the triple negative breast cancer. Conclusion : MRI finding may be helpful for differentiation between triple negative and non-triple negative breast cancer.

Shape and Incidence of Rib Variations in Chest Radiographs (단순흉부촬영상 관찰되는 늑골 변이의 양상 및 빈도)

  • Joo, Ji-Seon;Bae, In-Young;Kim, Sung-Tae;Kwak, Seung-Min;Cho, Chul-Ho;Cho, Seung-Wook;Park, Chan-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • Background: The literature on variations of rib is limited. Very little has been written in the radiological journal of this country on the subject. It seemed of interest to investigate the nature and incidence of congenital variations in a series of routine chest roentgenograms. The topic of rib variations has not been covered extensively in the radiological journals in Korea. This has presented an opportunity to investigate the nature, type, shape and incidences of congenital rib variations in normal Korean adults from a series of routine roentgenograms. Methods: Chest radiographs of 5,000 adults, who visited our hospital for a routine check-up or for employment physical examinations from January 1996 to September 1998, were consecutively reviewed. The sex distribution consisted of 2,827 male males and 2,173 female females(ratio of 1.3:1) with the age range aged between 19 and 65 years(mean age: 34.6 years) were included. The chest PAs were analyzed for the presence, type, location, and shape of the rib variations. From this data the incidence of each type of variations was calculated. Results: Seventy-six of the 5,000 adults(1.52%), 63 male(2.23%) and 13 female(0.6%), showed 88 cases of rib variation(Table 1). The most common variation was the bifid rib(n=35), followed by hypoplasia of the rib(n=22), flaring of the rib(n=18), bridging of the ribs(n=7), cervical ribs(n=3), and fusion of between ribs(n=3)(Table 2). The bifid rib(Table 1) was found most frequent in the right fourth rib(12/35, 34.3%), followed by the left fifth rib(6/35, 17.1%) and right third rib(6/35, 17.1%). Hypoplasia of the rib was common in first rib(20/22, 90.9%). Flaring of the rib was common at fourth rib(8/18, 44.4%, right and left combined), and bridging between ribs was common between first and second rib(3/7, 42.9%). Conclusion : The percentage of incidence of rib variations in adults was 1.52%. Bifid rib was the most common variation, followed by hypoplasia, flaring, bridging, cervical rib, and fusion of ribs, in decreasing order.

  • PDF

Distribution of Epiphytic Bacteria and Acid-Tolerant Bacteria on the Phyllosphere in the Industrial and Clean Areas (공단지역 및 청정지역 식물 잎권의 잎표면세균 및 내산성세균의 분포)

  • Ahn, Jong-Hoon;Bang, Sook-Jin;Han, Nam-Jung;Song, Wang-Young;Hwang, Soyoung;Lee, In-Soo;Park, Seong Joo
    • Korean Journal of Microbiology
    • /
    • v.33 no.4
    • /
    • pp.262-266
    • /
    • 1997
  • Total, direct viable count, and acid-tolerant epiphytic bacterial population sizes were quantified on leaves of chestnut tree (Castanea crenata S. et Z.) near Taejon Industrial Estate affected by acid precipitation and deposition as well as in the clean natural forest area, Mt. Kyejok, in Taejon city from August 1996 to August 1997. Geometric mean numbers of total, direct viable count, and acid-tolerant epiphytic bacteria were $9.9{\times}10^5cell/cm^2$, $1.6{\times}10^6cell/cm^2$, and $7.1{\times}10^3cfu/cm^2$ respectively, being 1.5, 2, and 2.6 times those in the clean area. Acid-tolerant epiphytic bacterial numbers at pH 5.6 by MPN method were $3.3{\times}10^4$ in the industrial area, about the same as the number, $3.4{\times}10^4MPN/cm^2$, of the clean area. Acid-tolerant bacterial number at pH 4.0 was $1.9{\times}10^{-1}MPN/cm^2$ in the industrial area, whereas none was detected in the clean area. Acid-tolerant bacteria at pH 3.0 were not detected at all in the industrial area as well as in the clean area. Epiphytic bacterial population sizes were generally the greatest in May when leaves are emerged and grew hut the lowest in November when defoliation occurs. These results showed that air pollutant deposition on leaves did not cause a decrease of epiphytic bacteria at least and acid deposition on leaves did cause an increase of acid-tolerant bacteria.

  • PDF

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

PROPOSAL OF NEW DENIAL COLOR-SPACE FOR AESTHETIC DENIAL MATERIALS (치과용 심미 수복 재료들의 색상 연구를 통한 새로운 치과용 색체계의 제안)

  • Oh, Yun-Jeong;Park, Su-Jung;Kim, Dong-Jun;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Time Change in Spatial Distributions of Light Interception and Photosynthetic Rate of Paprika Estimated by Ray-tracing Simulation (광 추적 시뮬레이션에 의한 시간 별 파프리카의 수광 및 광합성 속도 분포 예측)

  • Kang, Woo Hyun;Hwang, Inha;Jung, Dae Ho;Kim, Dongpil;Kim, Jaewoo;Kim, Jin Hyun;Park, Kyoung Sub;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • To estimate daily canopy photosynthesis, accurate estimation of canopy light interception according to a daily solar position is needed. However, this process needs a lot of cost, time, manpower, and difficulty when measuring manually. Various modeling approaches have been applied so far, but it was difficult to accurately estimate light interception by conventional methods. The objective of this study is to estimate the spatial distributions of light interception and photosynthetic rate of paprika with time by using 3D-scanned plant models and optical simulation. Structural models of greenhouse paprika were constructed with a portable 3D scanner. To investigate the change in canopy light interception by surrounding plants, the 3D paprika models were arranged at $1{\times}1$ and $9{\times}9$ isotropic forms with a distance of 60 cm between plants. The light interception was obtained by optical simulation, and the photosynthetic rate was calculated by a rectangular hyperbola model. The spatial distributions of canopy light interception of the 3D paprika model showed different patterns with solar altitude at 9:00, 12:00, and 15:00. The total canopy light interception decreased with an increase of surrounding plants like an arrangement of $9{\times}9$, and the decreasing rate was lowest at 12:00. The canopy photosynthetic rate showed a similar tendency with the canopy light interception, but its decreasing rate was lower than that of the light interception due to the saturation of photosynthetic rate of upper leaves of the plants. In this study, by using the 3D-scanned plant model and optical simulation, it was possible to analyze the light interception and photosynthesis of plant canopy under various conditions, and it can be an effective way to estimate accurate light interception and photosynthesis of plants.

Distribution of Flora and Naturalized Plants in Gwangpo Bay, Sacheon (사천시 광포만의 식물상 및 외래식물 분포)

  • Lee, Min-Sook;Kim, Jung-Soo;Park, Sam-Bong;Cho, Gab-Ja;An, Jong-Bin;Song, Jin-Heon;Kwag, Chil-Sig;Kim, Bong-Gyu;Choo, Gab-Chul
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.369-392
    • /
    • 2021
  • This study aimed to provide basic data for efficient flora management of vascular plants, halophytes, and naturalized plants in the Gwangpo Bay area in Sacheon city, Gyeongsangnam-do. The flora found in this area incorporated 520 taxa, including 93 families, 299 genera, 466 species, 3 subspecies, 41 varieties, and 10 forma, and accounted for approximately 10.6% of total vascular plants (4,884 species) in Korea. According to the survey, 76 species of Gramineae showed the highest frequency (14.6%), followed by 67 species of Compositae (12.8%), 34 species of Leguminosae (6.5%), 27 species of Cyperaceae (5.2%), and 22 species of Rosaceae (4.2%). Rare plant species designated by the Korea Forest Service were categorized into six taxa, including three taxa in the LC grade, one taxon in the CR grade, one taxon in the VU grade, and one taxon in the EN grade. Korea endemic plants belonged to nine taxa consisting of seven families, seven genera, and nine species. The special floristic plants included 44 taxa, including one taxon (Prunus yedoensis) in the V grade, four taxa in the IV grade, ten taxa in the III grade, six taxa in the II grade, and 23 taxa in the I grade. Naturalized plants included 62 taxa consisting of 15 families, 47 genera, 59 species and 3 varieties. Halophytes consisted of 27 taxa, including 13 families, 24 genera, 24 species, 2 varieties, 1 forma, which consisted of Atriplex gmelinii, Suaeda glauca, Suaeda maritima, and Lathyrus japonicus. Invasive alien species in the Gwangpo Bay area included seven taxa. Since Ambrosia artemisiifolia, Sicyos angulatus, andPaspalum distichum var. indutummay have harmful effects on native plants, these plants must be artificially controlled.

Thermal Effects on the Development, Fecundity and Life Table Parameters of Aphis craccivora Koch (Hemiptera: Aphididae) on Yardlong Bean (Vigna unguiculata subsp. sesquipedalis (L.)) (갓끈동부콩에서 아카시아진딧물[Aphis craccivora Koch (Hemiptera: Aphididae)]의 온도발육, 성충 수명과 산란 및 생명표분석)

  • Cho, Jum Rae;Kim, Jeong-Hwan;Choi, Byeong-Ryeol;Seo, Bo-Yoon;Kim, Kwang-Ho;Ji, Chang Woo;Park, Chang-Gyu;Ahn, Jeong Joon
    • Korean journal of applied entomology
    • /
    • v.57 no.4
    • /
    • pp.261-269
    • /
    • 2018
  • The cowpea aphid Aphis craccivora Koch (Hemiptera: Aphididae) is a polyphagous species with a worldwide distribution. We investigated the temperature effects on development periods of nymphs, and the longevity and fecundity of apterous female of A. craccivora. The study was conducted at six constant temperatures of 10.0, 15.0, 20.0, 25, 30.0, and $32.5^{\circ}C$. A. craccivora developed successfully from nymph to adult stage at all temperatures subjected. The developmental rate of A. craccivora increased as temperature increased. The lower developmental threshold (LT) and thermal constant (K) of A. craccivora nymph stage were estimated by linear regression as $5.3^{\circ}C$ and 128.4 degree-days (DD), respectively. Lower and higher threshold temperatures (TL, TH and TH-TL, respectively) were calculated by the Sharpe_Schoolfield_Ikemoto (SSI) model as $17.0^{\circ}C$, $34.6^{\circ}C$ and $17.5^{\circ}C$. Developmental completion of nymph stages was described using a three-parameter Weibull function. Life table parameters were estimated. The intrinsic rate of increase was highest at $25^{\circ}C$, while the net reproductive rate was highest at $20^{\circ}C$. Biological characteristics of A. craccivora populations from different geographic areas were discussed.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.