• Title/Summary/Keyword: Distribution Department

Search Result 23,864, Processing Time 0.048 seconds

Irradiance Distribution Analysis of a Squid Jigging Vessel Using an LED Plus Metal Halide Fishing Lamp Combination Under Optimized Conditions (메탈할라이드와 엘이디 오징어 집어등의 겸용시 배치조건에 따른 수중조도분포 비교분석)

  • Jung, Mee Suk;Lee, Ki Dae;Ko, Jae Seok;Bae, Jae Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.315-325
    • /
    • 2014
  • A combination of MHL and LED fish-luring light is used in this study. Its yield, characteristics, and irradiance distribution are evaluated and analyzed. To obtain an irradiance distribution similar to that of an MHL, we suggest the optimal arrangement of MHL and LED.

Pharmacokinetics of Tobramycin in Patients with Hematologic Malignancy (혈액암 환자에 있어서의 Tobramycin Pharmacokinetics)

  • Yeom, Mikyong;Shin, Wan-Gyoon;Lee, Min-Hwa
    • Korean Journal of Clinical Pharmacy
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 1991
  • Tobramycin is one of the most frequently selected agents for pharmacokinetic drug monitoring because of its narrow therapeutic index and essential role for the management of serious infections, especially gram-negative infections. Its pharmacokinetic parameters are dependent on race, sex, age, ideal body weight. disease states, and etc. Therefore, to schedule the dosing of tobramycin, the individual pharmacokinetic parameters such as half-life and volume of distribution are needed. However, these pharmacokinetic parameters have never been reported in Koreans. The purposes of this study were to evaluate the volume of distribution of tobramycin in cancer patients who had normal renal function, to compare the mean values of Vd reported in the literature, and to compare the measured half-life with the expected half-life based on ABW, LBW, and IBW, respectively. Venous blood samples were collected just before and thirty minutes after dosing during steady state. Serum tobramycin concentrations were determined by $TD_x$ (fluorescence immunoassay). IBW were measured by the method of Devine: and LBW were measured by the method of Hallynck. Creatinine clearances (CLcr) of the patients were estimated using the Cockcroft and Gault equation. Elimination rate constants (kel) were determined using the Welling and Craig equation. Infusion rate (ko), volume of distribution (Vd), and half-life $(t_{1/2})$ were determined using the Saw chuk and Zaske equation. The volume of distribution Was $27\%$ greater than the Schentag's study (0.26 vs 0.33 l/kg), but the half-life was similar to the Levy's study. The predicted half-lives based on IBW were the closest to actual half-lives (1.85 vs 2.01 hr).

  • PDF

A COMPARISON OF POST AND CORE TECHNIQUES WITH FINITE ELEMENT ANALYSIS (유한요소법에 의한 Post와 Core 형성법의 비교)

  • Cheong, Yong-Kee;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.70-86
    • /
    • 1996
  • The purpose of this study was to analyze the stress distribution in mandibular second premolars restored with different post and core techniques. Sixteen two-dimensional finite element model of mandibular second premolars restored with post and core and complete crown were developed according to the diameter, length, and material of post and core. Vertical force, 10N in magnitude, was applied first to the central fossa and then $45^{\circ}$ oblique force of same magnitude was applied to the buccal contact surface of buccal cusp. The obtained results were as follows : 1. Stress distribution within the dentin 1) Regardless of the material of the post and core and the diameter and length of the post, the pattern of stress distribution within the dentin was similar. 2) Maximum dentinal stress was observed on the lingual root surface of alveolar crest level with oblique loading and on lingual side of root dentin at the crown margin on vertical loading. 3) Cast post and cores produced the lowest dentinal stress concentrations and the highest stress concentration was observed in composite resin post and cores. 2. Stress distribution within the post and core 1) Within the amalgam and composite resin post and core, the patterns and maximum values of stress were similar. Maximum stress located at the central fossa of core portion on vertical loading and at the lingual junction of post and core with oblique loading. 2) Among the all post and cores, the cast post and core registered the highest stress concentration and maximum stress value within the post. Maximum stress located at the post apex on vertical loading and at lingual half of the post surface with oblique loading. 3) In case of Para-post and amalgam core, maximum stress located at the central fossa of core portion and lingual tip of the post head on vertical loading. With oblique loading, maximum stress located at the lingual half of the post surface.

  • PDF

Spatial Distribution and Residual Consistency Assessment of PBDEs in the Surface Sediment of the Masan Bay (마산만 표층퇴적물 내의 폴리브롬화디페닐에테르(PBDEs)의 공간적 분포 및 오염도평가)

  • We, Sung-Ug;Yoon, Cho-Hee;Min, Byung-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.427-436
    • /
    • 2010
  • A total of 18 surface sediments within the special conservation zone in the Masan Bay were analyzed to investigate the spatial distribution and polluted pathway of polybrominated diphenyl ehters(PBDEs). Twenty-two PBDE congeners were detected and brominated diphenyl ether-209 (BDE-209) among them was predominant. The concentrations of BDE-209 and ${\Sigma}_{21}$PBDEs (sum of 21 PBDE congeners without BDE-209) ranged from 2.32 to 64.2 ng/g and from 0.72 to 8.24 ng/g, respectively. The spatial distribution of both BDE-209 and ${\Sigma}_{21}$PBDEs showed a negative gradient from the inner to the outer Bay, indicating that the source of PBDEs might be mainly located inside the Bay such as streams and an effluent of wastewater treatment plants. It was seemed likely that the major parameters determining levels of PBDEs in the Masan Bay were the distance discharging from their sources as well as the characteristics and movement of sediments due to the flow of sea water.

Insight Into the Crystallinity of Chinese Ancient Silk by Synchrotron Radiation-Based and Conventional X-ray Diffraction Methods

  • Gong, Decai;Zhang, Xiaoning;Gong, Yuxuan
    • Journal of Conservation Science
    • /
    • v.36 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • This study investigates the crystallinity distribution of ancient silk. Owing to the inherent multi-hierarchical structure of silk protein and the complicated structural changes that occur due to various burial environments, it is challenging but worthwhile to study ancient silk ageing behavior, which is based on the fact that ageing begins with a single fiber and then spreads to a whole fabric. Crystallinity was one of the most effective indicators found to reveal the ageing status of silk. Therefore, a synchrotron radiation-based X-ray diffraction(SR-XRD) method was employed to study the crystallinity distribution of single fibers of ancient silk unearthed from seven archaeological sites in China from historical periods including the warring states, Han dynasty, Song dynasty, and Ming dynasty. In comparison, the conventional X-ray diffraction method, which uses large amounts of samples, was also performed to determine the integral crystallinity of ancient silk. Thermal stability experiments by thermogravimetry(TG) as well as morphology observations by scanning electron microscopy(SEM) and optical microscopy(OM) all confirmed the deterioration of ancient silk. Moreover, the ageing mechanism of ancient silk was proposed with the assistance of an artificial ageing study. The results confirmed the effectiveness of SR-XRD as an ageing indicator, revealing the crystallinity distribution. This research could provide motivation to determine the deterioration status of ancient silk, and would also aid in explaining the fragility of ancient silk due to ageing.

Analysis of Channel Water Loss of the Agricultural Water Supply in a Gyeongcheon Drought Area (경천가뭄지역 농업용수 공급량의 수로손실 분석)

  • Cho, Gun Ho;Moon, Jin Kyoung;Choi, Kyung Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.2
    • /
    • pp.53-62
    • /
    • 2020
  • The purpose of this study is to estimate the channel water loss of agricultural water supply in the command areas belong to Yechon irrigation channel of Gyeongcheon reservoir located Mungyeong-si, which area experienced a severe drought in 2015. The channel water loss was estimated by comparison of the irrigation water requirements (IWR) and agricultural water supply of the field data from 2012 to 2015. Further analysis was conducted to define the conveyance loss estimated based on the leakage holes and illegal pumping spots investigated through the field survey, and the distribution loss obtained by subtracting conveyance loss from the channel water loss. The annual rainfall decreased gradually, but the contribution of effective rainfall, available rain water to crop, increased to IWR during the study period. These phenomena resulted in the increase of agricultural water supply, and hence made greater the channel water loss simultaneously. The average channel water losses estimated as 36.8 % with 7.1 % of the conveyance loss and 29.7 % of distribution loss respectively. The distribution loss seems to be related to total number of rainy days, and irrigation schedules, while the conveyance loss was caused by irrigation channel aging conditions and illegal intake problems. In order to achieve sustainable agricultural water resources, the channel water loss needs to be reduced through the restoration of aged irrigation facilities and effective water managements in the fields.

Adsorption and Separation Behaviors of Metal Ions Using a Poly-Dibenzo-18-Crown-6 in Aqueous Solution (수용액에서 Poly-dibenzo-18-crown-6를 이용한 금속이온들의 흡착 및 분리 특성)

  • Kim, Hae Joong;Chang, Jeong Ho;Shin, Young-Kook
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.248-253
    • /
    • 1998
  • The adsorption and separation behaviors of alkali, alkaline earth and transition metal ions using a poly-dibenzo-18-crown-6 were investigated in aqueous solution. The adsorption degree(E) and distribution ratio(D) of alkali, alkaline earth metal ions were Li(I)$t_R$) of metal ions were affected by the adsorption degree(E) and distribution ratio(D). This results showed good separation efficiency of K(I), Sr(II), Ag(I) and Pb(II) from the mixed metal solution.

  • PDF

3D Spatial Distribution Modeling for Petrophysical Property of Gas Hydrate-Bearing Sediment using Well Data in Ulleung Basin (울릉분지 시추공 분석 자료를 이용한 가스하이드레이트 함유층의 3차원 공간 물성 분포 추정)

  • Lee, Dong-Gun;Shin, Hyo-Jin;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.156-168
    • /
    • 2013
  • Drilling expedition #1 in 2007 and drilling expedition #2 in 2010 were performed for gas hydrate resources evaluation and optimal site selection of pilot test in Ulleung basin, East Sea, Korea. This study presents to build the 3D spatial distribution models using the estimated sedimentary facies, porosity, and gas hydrate saturation derived by well logs and core analysis data from UBGH1-4, UBGH1-9, UBGH1-10, UBGH1-14, UBGH2-2-1, UBGH2-2-2, UBGH2-6, UBGH2-9, UBGH2-10 and UBGH2-11. The objective of 3D spatial distribution modeling is to build a geological representation of the gas hydrate-bearing sediment that honors the heterogeneity in 3D grid scale. The facies modeling is populating sedimentary facies into a geological grid using sequential indicator simulation. The porosity and gas hydrate saturation modeling used sequential Gaussian simulation to populate properties stochastically into grid cells.

Analysis of thoracic epidurography and correlating factors affecting the extent of contrast medium spread

  • Hong, Ji Hee;Oh, Jung Hue;Park, Ki Bum
    • The Korean Journal of Pain
    • /
    • v.29 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • Background: Thoracic epidural anesthesia is frequently used to maintain intraoperative and postoperative analgesia. Frequently, 3 ml of local anesthetic is used as a test dose, or for intermittent epidural injection. We assessed the extent of the spread of 3 ml of contrast medium in the thoracic epidural space and attempted to identify any correlating factors affecting the epidurography. Methods: A total of 70 patients were enrolled in the study, and thoracic epidural catheterizations were performed under fluoroscopic guidance. Using 3 ml of contrast medium, epidurography was evaluated to confirm the number of spinal segments covered by the contrast medium. Correlation analysis was performed between patient characteristics (sex, age, body mass index, weight, height, and location of catheter tip) and the extent of the contrast spread. Results: The mean number of vertebral segments evaluated by contrast medium was $7.9{\pm}2.2$ using 3 ml of contrast medium. The contrast spread in the cranial direction showed more extensive distribution than that in the caudal direction, with statistical significance (P < 0.01). Patient height demonstrated a negative correlation with the extent of distribution of contrast medium (r = -0.311, P < 0.05). Conclusions: Thoracic epidurography using 3 ml of contrast medium results in coverage of a mean of $7.9{\pm}2.2$ spinal segments, with more extensive cranial spread, and patient height showed a weak negative correlation with the distribution of contrast medium.

Characterization of Size Distribution and Water Solubility of 15 Elements in Atmospheric Aerosols

  • Park, Jeong-Ho;Sun, Jeong-Min;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.1-7
    • /
    • 2001
  • The elemental characteristics of atmospheric aerosols were investigated as a function of particle size and water solubility. The aerosol particles were samples at 12 individual size ranges between 0.01 and 30㎛. Collected aerosol particles were separated into both soluble and insoluble components. The concentrations of 15 elements in both components were determined by a PIXE analysis using a 2.0 MeV-proton beam. In general, the mass size distribution of particulate matter was represented as a bimodal distribution. The maximum rations of S in July and December were 5.5 and 3.8 %, and they appeared in the size range of 0.47∼1.17㎛(stage No. 6 or 7) . The ratios of a S at non-separated size were 3.1 and 2.2 % in July and December, respectively, On the other hand, the maximum rations of Si in July and December were 7.0 and 5.4% and they appeared in the size range of 5.1∼30㎛(stage No. 0∼2). The ratios of Si at the non-separated size were 2.1 and 1.8% in July and December, respectively, The mass diameter of 12 elements ranged between 0.59㎛ of S and 3.20 of Fe. More than 90% of atmospheric aerosols consisted of the light elements such as C, N, O, H and Al. The soluble component was dominant in the smaller size range and the insoluble component in the larger size range. Large portions of Si. Ti and Fe existed in insoluble state. By contrast, S, Cl, Ca, Zn and Br were dissolved in water.