• Title/Summary/Keyword: Distributed temperature

Search Result 1,222, Processing Time 0.028 seconds

Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang Doo;Kim, Yi-Gon;Lee, Bong Kuk;Bae, Young Chul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.2
    • /
    • pp.187-192
    • /
    • 2004
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experimental results of the simulation.

Fundamental characteristic analysis on 6 T-class high-temperature superconducting no-insulation magnet using turn-distributed equivalent circuit model

  • Liu, Q.;Choia, J.;Sim, K.;Kim, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.44-48
    • /
    • 2021
  • In order to obtain ultra-high resolution MRI images, research and development of 11 T or higher superconducting magnets have been actively conducted in the world, recently. The high-temperature superconductor (HTS), first discovered in 1986, was very limited in industrial application until mid-2010, despite its high critical current characteristics in the high magnetic field compared to the low-temperature superconductor. This is because HTS magnets were unable to operate stably due to the thermal damage when a quench occurred. With the introduction of no-insulation (NI) HTS magnet winding technology that does not burn electrically, it could be expected that the HTS magnets are dramatically reduced in weight, volume, and cost. In this paper, a 6 T-class NI HTS magnet for basic characteristic analysis was designed, and a distributed equivalent circuit model of the NI coils was configured to analyze the charging current characteristics caused by excitation current, and the charge delay phenomenon and loss were predicted through the development of a simulation model. Additionally, the critical current of the NI HTS magnets was estimated, considering the magnetic field, its angle and temperature with a given current. The loss due to charging delay characteristics was analyzed and the result was shown. It is meaningful to obtain detailed operation technology to secure a stable operation protocol for a 6T NI HTS magnet which is actually manufactured.

A study of Heat Transfer by the Finite Element Method - Around Square Heat Source - (유한요소법에 의한 열전달 연구 -4각열원 주위-)

  • 장재은
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.26-33
    • /
    • 1998
  • This paper subdivided the interior solid into triangular shape of equal size to calculate the temperature distribution around the square heat source of it, and compared calculated values with measured ones. The result obtained are as follows. 1) It was found that we can calculate the temperature distribution around the square heat source of interior solid by the variational method of the finite element method as the calculated values were almost accord with the measured ones. 2) The temperature distributed were higher when the distances between heat source were farther and lower when those nearer. 3) Vertical surface temperature distribution is remarkably efficient by thermal conductivities.

  • PDF

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Experimental Study on Levee Monitoring System for Abnormality Detection Using Fiber Optic Temperature Sensing (광섬유 온도 센싱을 활용한 제방의 이상 감지 모니터링 시스템에 대한 실험 연구)

  • Ahn, Myeonghui;Ko, Dongwoo;Ji, Un;Kang, Joongu
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.120-127
    • /
    • 2019
  • Medium-scale levee experiments were performed to monitor the infiltration and failure of levee body by applying fiber optic temperature sensing. In this study, bio-polymer soil was spread in the levee slope to increase the strength and intensity. Therefore, the infiltration and failure by overflows were produced in a different way compared to general soil type of levees. This was also observed in the experiment data for temperature changes monitored by fiber-optic distributed temperature sensing system. Through the analysis of temperature changes at specific location by time, the location and initiation time for physical changes and infiltration in levee body could be identified based on temperature variation. In this experiment, the time of rapid changes in temperature was ahead in the inland slope rather than the forceland slope. It was corresponding to the levee failure sequence of first inland slope failure and then the forceland slope failure.

Linear Interrogation of Distributed Fiber Grating Temperature Sensor Network using a Fabry-Perot ITU Filter (Fabry-Perot ITU 필터의 기준파장을 이용한 분배형 광섬유 격자 온도센서의 선형복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.54-60
    • /
    • 2007
  • We constructed a fiber-optic temperature sensor system using a sensor array with 15 fiber Bragg gratings for distributed temperature monitoring in electrical power systems. A polynomial fitting algorithm was used to compensate the nonlinear action of the MEMS tuneable wavelength filter used for Bragg wavelength demodulation Fixed passband wavelengths from a Fabry-Perot ITU filter were used as reference wavelengths for the fitting algorithm which obtained constant accuracy regardless of the wavelength scanning range and frequency. About 0.18[%] of linearity error compared to reference thermocouple thermometer has been obtained in the preliminary experimental results.

Comparing a Perspective on the Leaf Burst Timing and Leaf Growth Performance of Major Plants observed in Urban Forests (도시녹지 내 주요 식물상의 개엽시기 및 잎의 성장 특성 비교)

  • Jang, Gab-Sue
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.127-136
    • /
    • 2012
  • Global climate change and urban heat island have been the main factors which changed leaf burst timing and leaf growth performance in urban forests. Therefore, the ecosystem in urban forests were modified and the types and composition of wildlives, living in the urban forests, were desperately changed due to the urban heat island. This study was done to identify phenological phenomena appeared in urban forests due to the urban climate change by comparing the morphological changes of leaves due to the change of temperature in Spring. The study focused on nine urban forests distributed in Daegu city, where weekly temperature and the morphological changes of the plants were mainly observed. Urban forests had different temperature depending on where each was located in the urban area. The difference of temperature in forests in and outside the urban area was verified by SPSS (Statistical Package for the Social Sciences), which divided the urban forests into about three groups; the one located outside the city, another group located in the middle of the city, and the other located close to the outside forests. The forests located in the middle of the city were showing the earlier leaf burst timing and leaf growth performance, while forests, distributed outside the city, were showing relatively late leaf burst timing and leaf performance.

Wire-wrap Models for Subchannel Blockage Analysis

  • Ha K.S.;Jeong H.Y.;Chang W.P.;Kwon Y.M.;Lee Y.B.
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.165-174
    • /
    • 2004
  • The distributed resistance model has been recently implemented into the MATRA-LMR code in order to improve its prediction capability over the wire-wrap model for a flow blockage analysis in the LMR. The code capability has been investigated using experimental data observed in the FFM (Fuel Failure Mock-up)-2A and 5B for two typical flow conditions in a blocked channel. The predicted results by the MATRA-LMR with a distributed resistance model agreed well with the experimental data for wire-wrapped subchannels. However, it is suggested that the parameter n in the distributed resistance model needs to be calibrated accurately for a reasonable prediction of the temperature field under a low flow condition. Finally, the analyses of a blockage for the assembly of the KALIMER design are performed. Satisfactory results by the MATRA-LMR code were obtained through and rerified a comparison with results of the SABRE code.

The Development of Boiler Fuel Control Algorithm and Distributed Control System for Coal-Fired Power Plant (석탄화력발전소 보일러 연료제어 알고리즘과 분산제어시스템의 개발)

  • Lim, Gun-Pyo;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.36-44
    • /
    • 2013
  • This paper is written for the development and application of boiler fuel control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. Fuel control algorithm has the upper algorithm and it is boiler master control algorithm that controls the fuel, feed water, air by generation output demand. Generation output demand by power load influences fuel control. Because fuel can not be supplied fast to the furnace of boiler, fuel control algorithm was designed adequately to control the steam temperature and to prevent the explosion of boiler. This control algorithms were coded to the control programs of distributed control systems which were developed domestically for the first time. Simulator for coal-fired power plant was used in the test step. After all of distributed control systems were connected to the simulator, the tests of the actual power plant were performed successfully. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

Transient Liquid Phase Bonding of Ni-Cr Heat Resisted Cast Steel (Ni-Cr계 내열주강의 천이액상 접합)

  • 권영순;신철균;김현식;김환태;김지순;석명진
    • Journal of Powder Materials
    • /
    • v.9 no.3
    • /
    • pp.189-198
    • /
    • 2002
  • In this work, transient liquid phase (TLP) bonding of Ni-Cr heat resisted cast alloy (HP) was investigated. And also the behaviors of the solid particles distributed in the interlayer during TLP bonding were investigated. The MBF-60 and solid particles (Ni, Fe, and $Al_2O_3$ powders respectively) added MBF-60 which will be a liquid phase coexisting with solid particles at the bonding temperature were used as insert metal. The effective and sound bonding was possible by spark plasma sinter-bonding due to the differences of electric resistance between base metal and liquid insert layer which creates high temperature region. During the isothermal solidification, $Al_2O_3$ particles and solid particles of liquid phase sintered insert metal have shown no growth, while Ni and Fe particles grow rapidly. In this TLP bonding using the MBF-60 and distributed Fe, Ni particles as insert materials, the whole isothermal solidification process was dominated by the growth rate of the solid particles distributed in the interlayer.