• 제목/요약/키워드: Distributed generations

검색결과 134건 처리시간 0.033초

전압 불평형율을 이용한 분산전원의 고립운전 검출 기법 (An Islanding Detection Method for Distributed Generations Using the Voltage Unbalance)

  • 장성일;박종근;김황호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.42-44
    • /
    • 2004
  • This paper introduced and proposed the voltage unbalance of DC terminal output as new monitoring parameter for power islanding detection. This paper also presented a simple and novel detection algorithm, which effectively combines the detection results of the conventional parameter, voltage magnitude, and a newly proposed parameter. We tested the proposed method using several distribution network conditions including not only islanding operation conditions, but also non-islanding conditions of normal network load variations. The test results showed that the proposed parameters and algorithm are capable of correctly detecting the islanding operation not affected by variation of DG loading and also have a good selectivity for islanding conditions and non-islanding conditions.

  • PDF

분산전원이 연계된 배전계통에서 보호협조기기의 운용특성에 관한 연구 (Operating Characteristics of Protection Coordination Devices in Distribution System interconnected with Distributed Generation)

  • 김소희;지성호;김선영;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.35-45
    • /
    • 2011
  • 최근 정부의 녹색성장 정책에 의해 배전계통에 태양광, 풍력발전 등과 같은 분산전원의 보급률이 지속적으로 증가되고 있는 실정이다. 이러한 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름은 단방향(One-direction)에서 양방향(Bi-direction)으로 변화되고 고장전류의 증 감이 발생하는 등, 다양한 변화가 생겨 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 양방향 보호협조검토가 가능한 보호협조 평가알고리즘을 제안하고, 그 알고리즘을 바탕으로 양방향 보호협조 평가시스템을 제작하였다. 또한 평가시스템을 이용하여 배전계통을 모델링하고 분산전원 연계 시 보호기기들 사이의 보호협조를 검토하여, 분산전원이 연계된 경우 배전계통에 발생할 수 있는 기술적인 문제점들을 분석하여 그 방안을 제시하였다.

분산전원이 연계된 배전계통에 보호협조기기 평가시스템의 최적운용에 관한 연구 (A study on Optimal Operation of Protection Coordination Devices Evaluation System in Distribution System with Distributed Sources)

  • 지성호;송방운;김병기;노대석
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2971-2978
    • /
    • 2013
  • 최근 배전계통은 정부의 녹색성장 정책으로 태양광, 풍력발전 등과 같은 분산전원의 보급률이 지속적으로 증가되고 있는 실정이다. 이러한 분산전원의 연계로 기존 배전계통의 조류흐름은 단방향(One-direction)에서 양방향(Bi-direction)으로 변화되고, 고장전류의 증 감이 발생하는 등, 다양한 변화가 생겨 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 양방향 보호협조 검토가 가능한 보호협조 평가알고리즘과 실제의 사고전류 값을 이용한 개선된 T-C곡선 알고리즘을 제안하고, 이 알고리즘을 바탕으로 양방향 보호협조 평가시스템을 개선하였다. 또한 평가시스템을 이용하여 배전계통을 모델링하고, 분산전원 연계 시 보호기기들 간의 보호협조를 검토하여, 분산전원이 연계된 경우 배전계통에 발생할 수 있는 기술적인 문제점들을 분석하여 그 방안을 제시하였다.

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

FACTORS AFFECTING AGE STRUCTURES AND GENETIC RESPONSES TO TRUNCATION SELECTION SCHEMES IN A POPULATION WITH OVERLAPPING GENERATIONS

  • Ghaffar, A.;Shimizu, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제6권4호
    • /
    • pp.497-507
    • /
    • 1993
  • Four truncation selection schemes (SSs) were framed to predict and compare the age structures and genetic responses under the influence of various factor employing the scheme-specific algorithms. Two paths of selection, sires (bulls' sires) and dams (bulls' dams) to breed young bulls were considered. Among variable factors, four levels (0.3, 0.5, 0.7, 0.9) of precision of evaluation, five levels (0.0, 0.05, 0.10, 0.15, 0.20 genetic standard deviation) of genetic differences among age classes and 4 levels of proportions selected (for bulls' sire, 0.05, 0.10, 0.125, 0.25, and for bulls' dams 0.02, 0.04, 0.05, and 0.10) contemplated on both paths of selection. The number of age classes for bulls' dams and bulls' sires were 4 or 8 and 2 or 4, respectively. The stayability across age classes for bulls' dams was assumed to be 0.80 or 0.60. The candidates for selection for bulls' sires were equally distributed (0.5 or 0.25) across the age classes. The SS1 (selection on same proportions as candidates' distribution) revealed longest generation lengths and lowest yearly genetic responses. The average ages were youngest and yearly genetic responses were highest in SS4 (selection at each age-specific truncation point with the same average genetic superiority of selected parents across the ages) and followed by SS3 (selection at each agespecific truncation point with same predicted genetic values) and SS2 (selection at common truncation point on phenotypic values) in a population with overlapping generations. The results revealed the importance of choosing suitable selection scheme to acquire maximum yearly genetic responses especially when the genetic differences among age classes are large and the precision of evaluation is relatively low.

아까시잎혹파리, Obolodiplosis robiniae (Diptera: Cecidomyiidae) 연간 밀도변동과 아까시나무 수관 내 분포 (Seasonal Fluctuation and Distribution of Obolodiplosis robiniae (Diptera: Cecidomyiidae) Within Crown of Robinia pseudoacacia (Fabaceae))

  • 이정수;정유미;최광식;김일권;권영대;전문장;신상철;최원일
    • 한국응용곤충학회지
    • /
    • 제48권4호
    • /
    • pp.447-451
    • /
    • 2009
  • 아까시잎혹파리(Obolodiplosis robiniae(Haldeman))는 아까시나무(Robinia pseudoacacia Linnaeus(Fabaceae)) 잎 가장자리에 혹을 형성하는 혹파리과 해충으로 북미대륙 동부가 원산으로 국내와 일본에 2002년 유입되었음이 보고되었다. 본 연구는 아까시잎혹파리의 계절별 밀도변동과 수관 내 분포를 구명하기 위하여 수행되었다. 밀도조사는 경기도 오산시 수청동과 시흥시 대야동의 아까시숲에서 5월부터 8월까지 조사되었으며 아까시잎혹파리 밀도는 잎당 유충수를 기준으로 추정되었다. 아까시잎혹파리 세대 수는 지역별로 차이가 있어, 오산에서는 3세대, 시흥에서는 2세대가 관찰되어 국내에서는 최대 3세대가 발생할 수 있음을 보여주었다. 오산지역 아까시나무내 아까시잎혹파리 유충 밀도분포는 수관 상부가 수관 중간 부분과 하부보다 높았다. 시흥지역 아까시나무의 수관 하부 바깥쪽 밀도가 안쪽보다 높았다. 아까시잎혹파리의 혹 당 유충수는 오산, 시흥에서 각각 $3.3{\pm}0.1$, $2.8{\pm}0.1$ 마리였다.

분산 시뮬레이티드 어닐링을 이용한 복합 재료 재단 (Composite Stock Cutting using Distributed Simulated Annealing)

  • 홍철의
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제29권1_2호
    • /
    • pp.20-29
    • /
    • 2002
  • 복합 재료로 구성된 원판으로부터 여러 가지 패턴을 버려지는 부분이 최소화되게 배치시킨 후 절단하는 문제를 복합 재료 재단 문제라 부른다. 본 논문은 목적 함수의 비용 오류를 감내하는 영역 분할 분산 시뮬레이티드 어닐링 알고리즘을 MPI 환경하에서 복합 재료 재단 문제에 적용한다. 비용 오류 감내기법은 최적해 접근 특성을 유지하기 위하여 스트림 길이를 동적으로 변화하며 상태변환을 비동기적으로 수행한다. 또한 복합 재료 재단 도구 개발을 위한 여러 가지 모양을 가진 패턴의 정보 및 친화도 생성, 목적함수, 상태변환 방법, 어닐링 스케줄 및 이를 위한 효율적인 자료 구조에 대하여 정의한다. 배치될 패턴은 정형이나 convex 다각형으로 제한되어 있지 않고 어떠한 모양도 가능하며 원판은 복합 재료의 성격상 2 또는 4 방향으로 고정되어 있다.

제어 가능한 전류원 기반의 인버터를 이용한 실제적 태양광 발전 시스템 모델링 (Modeling of Practical Photovoltaic Generation System using Controllable Current Source based Inverter)

  • 오윤식;조규정;김민성;김지수;강성범;김철환;이유진;고윤태
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1340-1346
    • /
    • 2016
  • Utilization of Distributed Generations (DGs) using Renewable Energy Sources (RESs) has been constantly increasing as they provide a lot of environmental, economic merits. In spite of these merits, some problems with respect to voltage profile, protection and its coordination system due to reverse power flow could happen. In order to analyze and solve the problems, accurate modeling of DG systems should be preceded as a fundamental research task. In this paper, we present a PhotoVoltaic (PV) generation system which consists of practical PV cells with series and parallel resistor and an inverter for interconnection with a main distribution system. The inverter is based on controllable current source which is capable of controlling power factors, active and reactive powers within a certain limit related to amount of PV generation. To verify performance of the model, a distribution system based on actual data is modeled by using ElectroMagnetic Transient Program (EMTP) software. Computer simulations according to various conditions are also performed and it is shown from simulation results that the model presented is very effective to study DG-related researches.

The Generic Attributes of the New Millennial Leaders

  • DAUD, Salina;WAN HANAFI, Wan Noordiana
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권12호
    • /
    • pp.455-464
    • /
    • 2020
  • As the millennials continue to mature and enter the workforce, it is important that employers understand what this generation expects from all aspects of their employment and leadership preferences in order to prepare them to be the next millennials leaders. The purpose of this research is to determine the generic attributes of the new millennial leaders in Malaysia. The survey is distributed among executives in the selected government-linked, multinational, and public-sector companies in Malaysia, with 237 (72%) of whom being millennials. Partial least square (PLS-SEM) via software SmartPLS 3.0 was applied to evaluate the measurement model and the structural model. Results from this study indicate that the attributes of the millennials leader are innovative (0.213), inspiration (0.128), and visionary (0.122). Thus, organization can focus on those attributes in preparing the millennials for being the next generation of leaders. This study offers important implications to researchers as well as practitioners, and highlights the leadership attributes that could help in enhancing millennials leadership. This study produces a new millennials leadership attributes model for millennials leaders in Malaysian companies; with millennials becoming the fastest-growing age groups in the organizations, this study will promote effective and efficient skills for the millennials.

Configurations of AC and DC-type Quality Control Center for a New Distribution System FRIENDS

  • Hayashi Yusuke;Saisyo Masaki;Ise Toshifumi;Tsuji Kiichiro
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.497-501
    • /
    • 2001
  • Unbundled power quality service is paid much attention under the circumstances of deregulation and diversification of needs of customers for quality and price of electric power. Moreover, distributed generators (DGs) such as photovoltaic generations and wind turbines will be introduced to distribution system more and more, and reverse flow of active power has possibility to cause new problems in the distribution system such as voltage rise of distribution line and protection problem. Flexible, Reliable and Intelligent Electrical eNergy Delivery System, which is called FRIENDS, has been proposed as one of promising distribution system for such requirements, and intensive studies are under way. One of features of the system is introducing Quality Control Center (QCC) into the system for unbundled power quality service and easy installation of DGs. Two types of QCCs for such purposes are proposed, and simulation results are shown in this paper.

  • PDF