• Title/Summary/Keyword: Distributed Generator

Search Result 204, Processing Time 0.021 seconds

Blockchain Oracle for Random Number Generator using Irregular Big Data (비정형 빅데이터를 이용한 난수생성용 블록체인 오라클)

  • Jung, Seung Wook
    • Convergence Security Journal
    • /
    • v.20 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • Blockchain 2.0 supports programmable smart contract for the various distributed application. However, the environment of running smart contract is limited in the blockchain, so the smart contract only get the deterministic information, such as block height, block hash, and so on. Therefore, some applications, which requires random information, such as lottery or batting, should use oracle service that supply the information outside of blockchain. This paper develops a random number generator oracle service. The random number generator oracle service use irregular big data as entropy source. This paper tests the randomness of bits sequence generated from oracle service using NIST SP800-22. This paper also describes the advantages of irregular big data in our model in perspective of cost comparing hardware entropy source.

A Diesel Generator Model with Fluctuating Engine Torque Including Magnetic Saturation for Transient Analysis using XTAP

  • Sakamoto, Orie
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1298-1303
    • /
    • 2015
  • Diesel engine generators are widely used in the world, especially in remote site power systems as distributed generators. A weak distribution feeder with a small diesel engine may suffer from voltage and power fluctuations due to misfiring of the engine cylinder. In this study, new generator model with example engine torque was developed for the electromagnetic transient analysis program for power systems named XTAP. The configuration and verification results of the developed model are presented in the paper. The model is considered to be useful for analyses of small power systems with those diesel engines.

Development of PSCAD Simulation Model for Doubly-fed Induction-type Wind Power Generation System (이중여자 유도형 풍력 발전기의 PSCAD 시뮬레이션 모델 개발)

  • Jeong, Byoung-Chang;Kim, Hee-Jung;Chung, Yong-Ho;Jeon, Young-Soo;Kwak, No-Hong;Song, Seung-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.261-264
    • /
    • 2006
  • In this paper, doubly-fed induction-type wind power generation system simulation model for grid connection is developed. The simulation model is based on PSCAD/EMTDC and consists of rotor-blade, blade controller, generator power converter and generator controller Blade controller controls the blade pitch angle for starting, peak power limiting and emergency condition. Generator controller controls the generator output power to maximize the system efficiency. Simulation results are shown for the variable wind speed conditions. The simulation model can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

  • PDF

A study on High Voltage Squarewave Pulse Generator (고전압 구형파 펄스 발생기에 관한 연구)

  • Kim, Young-Bae;Ryu, Hong-Je;Kim, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1022-1025
    • /
    • 2008
  • This paper presents the generation of the high voltage squarewave pulse using distributed RLC circuit. The demonstrated test was performed with the distributed RLC circuit which consists of the resistance, the inductance and the capacitance. Pspice simulation was also conducted about the experiment circuit. The result of the experiment was in good agreement with the result of the simulation. Theoretical analysis of the initial peak value at the squraewave pulse was derived from the results of the experiment and simulation. Additionally, the characteristics of the time delay was analyzed about the spherical gap switch and the surface discharge gap switch, respectively. It is concluded that the surface discharge gap switch is better than the spherical gap switch to reduce the time delay.

A Study On the Controller of Synchronous Generator for Distributed Generation (분산전원용 동기발전기의 제어기 모델링에 대한 연구)

  • Kim, C.S.;Kim, T.E.;Kim, J.E.;Hwang, J.S.;Ryu, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.220-222
    • /
    • 2002
  • DG (Distributed Generation) devices such as co-generation systems, fuel cells and photovoltaic power generation systems, etc is introducing into the distribution systems by the deregulation. In this paper, the controller of synchronous generator used for DG is newly designed in order to regulate the real & reactive power and the effect on the islanding phenomenon compared with the traditional controller.

  • PDF

Implementation of Fuzzy Control Algorithm For Nuclear Power Plant Steam Generator Level Control At Field Controller (원자력발전소 증기발생기 수위제어를 위한 퍼지제어기법의 현장 제어기계에의 적용)

  • 박기용;허우성;성풍현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.111-121
    • /
    • 1995
  • A fuzzy control algorithm of bell-type membership functions and 9 rules is constructed for narrow range level control of steam generators in nuclear power plants. It is implemented at a field digital distributed controller, a Westinghouse-made controller called Westinghouse Distributed Processing Family(WDPF). Performance for level control of the developed fuzzy controller is compared with that of conventional controller, both at the field controller. For these comparisons, both the fuzzy control algorithm and the conventional PI control algorithm were carefully tuned. Also the sampling time for optimal performance was investigated. The results show that the fuzzy control algorithm is not only better in performance than the conventional algorithm but also much easier to be tuned by operators in the field.

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.

Dynamic model and simulation of microturbine generation system for islanding mode operation (마이크로터빈발전시스템 독립운전을 위한 동적 모델링 및 시뮬레이션)

  • Hong, Won-Pyo;Cho, Jea-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.453-457
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market. In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for isolated operation. The system comprises of a Permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in islanding operation mode of a DG system.

  • PDF

Capacity Optimizing method of Distributed Generators in Stand-Alone Microgrid Considering Grid Link-Characteristics

  • Han, Soo-Kyeong;Choi, Hyeong-Jin;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1483-1493
    • /
    • 2018
  • Recently, more power facilities are needed to cope with the increasing electric demand. However, the additional construction of generators, transmission and distribution installations is not easy because of environmental problems and citizen's complaints. Under this circumstance, a microgrid system with distributed renewable resources emerges as an alternative of the traditional power systems. Moreover, the configuration of power system changes with more DC loads and more DC installations. This paper is written to introduce an idea of a genetic algorithm-based solution to determine the optimal capacity of the distributed generators depending on the types of system configuration: AC-link, DC-link and Hybrid-link types. In this paper, photovoltaic, wind turbine, energy storage system and diesel generator are considered as distributed generators and the feasibility of the proposed algorithm is verified by comparing the calculated capacity of each distributed resource with HOMER simulation results for 3 types of system configuration.

Control of Linear Generator Using Hydrogen as a Fuel (수소연소를 이용한 선형발전기 제어)

  • Lee, Seung-Hee;Jeong, Seong-Gi;Choi, Ju-Yeop;Choi, Jun-Young;Oh, Si-Doek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.391-394
    • /
    • 2008
  • Global warming and air pollution have increased the amount $CO_2$ in the atmosphere. In order to decrease the amount of $CO_2$, lots of researches are conducted toward using Hydrogen energy. Because of its high efficiency energy level and environmental friendly features, many companies have researched on developing hydrogen engine system and distributed generation system. Especially, the focus of this research provides the operation method of linear generator for hydrogen fuel combustion linear engine. During an ignition, linear generator is operated by motor to create the initial condition of engine combustion. Once the engine combustion is stabilized, the generator supplies electric power to grid. In order to stabilize the engine, linear generator is required to control mover frequency, direction, and force; Hence the PCS(Power Conversion System) place three H-bridge type inverter stacks in parallel to control phase current independently. As well, by using Back-to-Back method, it can receive electric power from both end.

  • PDF