• 제목/요약/키워드: Distillation tower

검색결과 20건 처리시간 0.019초

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Gamma Absorption Technique를 이용한 Trayed Column의 가동 중 내부 밀도분포 측정에 의한 유체 유동상태 진단 (In-service Investigation on the Flow Dynamics of a Trayed Column from the Measurement of an Internal Density by using a Gamma Absorption Technique)

  • 김재호;김종범;김진섭;이나영;이성식;장석준;정성희
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.35-40
    • /
    • 2008
  • 석유화학 공정의 증류탑은 공정유체를 분리, 정제하는 중요한 장치 중의 하나로 가동효율은 설비의 생산성에 큰 영향을 미친다. 본 연구는 밀봉 감마선원을 이용하여 투과 감마선의 세기를 높이별로 측정함으로써 내부 밀도의 변화를 분석하여 공정의 가동 중 내부 상황에 대한 정보를 얻고자 하였다. 이를 위하여 한국원자력연구원에서 개발된 자동 증류탑 검사장치를 이용하여 증류탑 상부 양쪽에 밀봉 감마선원과 방사선검출기를 매달아 수직으로 내리면서 실험을 수행하였으며, 이때 감마선원으로는 Co-60 150 mCi과 방사선검출기로 BGO detector를 각각 사용하였다. 진단결과 설비 내부의 tray에는 구조적 결함이 관찰되지 않았으나, 유체분포를 고려할 때 상부는 기포층(vapor)의 밀도분포가 지배적인 반면에, 하단부에는 기포에 비해 유체가 상대적으로 많이 분포하는 것으로 계측되었다. 본 실험으로부터 밀봉 감마선원을 이용한 가동 중에 있는 대형 증류탑의 tray에 대한 구조적 건전성 및 내부 유체분포에 대한 정보를 성공적으로 제시하였다.

2-부텐의 수첨이성화반응 및 증류공정을 통한 고순도 1-부텐의 제조 (Synthesis of Pure Butene-1 through Hydro-isomerization of Butene-2 and Distillation)

  • 조정호;전종기;송영하;이성준;이재호
    • Korean Chemical Engineering Research
    • /
    • 제45권4호
    • /
    • pp.351-355
    • /
    • 2007
  • $C_4$ 잔사유에 포함되어 있는 2-부텐을 부가가치가 더 높은 1-부텐으로 위치 이성화하는 공정의 개발이 필요하다. 본 연구에서는 2-부텐을 1-부텐으로 전환하기 위하여 상업용 Pd/alumina 촉매를 사용하여 수첨이성화반응 실험을 수행하였다. 상업용 Pd 촉매인 LD-265 촉매가 같은 반응조건에서 다른 상업용 촉매들보다 1-부텐 수율이 높았다. 1-부텐의 최적반응조건은 반응온도 $75^{\circ}C$, 반응압력 150 psig, 2-부텐의 유량 48 cc/h, $H_2$ 유량 48 cc/h이었으며, 이 조건하에서 1-부텐의 수율이 5.3%로 최대임을 알 수 있었다. 수첨이성화 반응기와 증류탑으로 구성된 공정의 모사를 수행하였다. 순도 99.0% 이상의 1-부텐을 얻기 위해서 단 효율이 78% 일 때 환류비가 120이고 171 단의 증류탑이 필요한 것으로 나타났다.

Osmotic membrane distillation with continuous regeneration of stripping solution by natural evaporation

  • Gryta, Marek
    • Membrane and Water Treatment
    • /
    • 제4권4호
    • /
    • pp.223-236
    • /
    • 2013
  • The paper presents an experimental set-up for osmotic membrane distillation, which can be operated continuously for several weeks. NaCl solutions were used as an osmotic solution. The influence of osmotic solution concentration on the obtained permeate flux is presented. The experimental set-up was equipped with a system for the regeneration of dilute brine. The regeneration was carried out using a method of natural evaporation to the air surrounding the installation. The evaporation area was created by the Białecki rings, assembled in the form of tower. The obtained evaporation rate was sufficient to maintain a constant NaCl concentration (over 300 g/L), for air with the relative humidity in the range of 30-80%. Accurel PP S6/2 hydrophobic polypropylene membranes were used in the study. The membranes exhibited 100% rejection for 600 h of the process duration.

석유정제산업에서의 유기성 유해대기오염물질의 비산배출량 산정 (Estimation of Fugitive Emission of Organic Hazardous Air Pollutants from Oil Refinery Industry)

  • 양성봉;유미선;이영준;유은진;최성헌
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.229-237
    • /
    • 2008
  • Hazardous air pollutants emitted from the oil refinery plant were surveyed from 1993 US and 2005 Korean TRI data. Toluene, xylene, methanol, MTBE and n-hexane, relatively large in amount of fugitive emission, are considered as candidates of newly designated HAPs in Korea. The sealed oil pump, one of equipments among fugitive sources in the crude oil distillation tower was examined for the estimation of amounts of annual HAPs emissions according to several calculation methods using registered emission factors. Emission rates showed to be decreased with following calculation factors; average emission factor>pegged emission factor>concentration emission factor>correlation equation. Annual emission amounts of benzene, toluene, xylene. ethyl benzene and nhexane from the distillation tower were estimated and amounts of these HAPs calculated with TVOC concentrations obtained from LDAR program and correlation equations showed only 6% of those from using concentration factors.

In-Service Identification of the Heterogeneous Zone in Petrochemical Pipelines by Using Sealed Gamma-Ray Sources $(^{60}Co,\;^{137}Cs)$

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.169-173
    • /
    • 2006
  • In-service diagnoses of pipeline facilities are important for a systematic maintenance of them. Field applications by using sealed gamma-ray sources $(^{60}Co,\;^{137}Cs)$ were performed to identify the heterogeneous zone in the pipelines of a distillation tower and a flare stack respectively. From the results, the heterogeneous zones in the pipelines were successfully identified. In the case of the pipeline connected to the distillation tower, a vapor pocket was detected in the fluid under hydrodynamic conditions, which could explain the reason for a decrease of the flow rate. In another case, an area with some amount of catalyst deposits was found at the bottom of the gas pipeline which was connected to the flare stack. And these findings provided important information for the process operators. Diagnosis technique by using gamma radiation sources has been proven to be an effective and reliable method for providing information on a media distribution in a facility.

위핑 유동 조건에서의 직사각형 체 주위 유동의 수력학적 분석 (Hydrodynamic Analysis of Rectangular Sieve Tray under Weeping Conditions)

  • 호산나 우위톤즈;이인원
    • 한국가시화정보학회지
    • /
    • 제15권3호
    • /
    • pp.34-40
    • /
    • 2017
  • Within fractionating devices existing in separation and purification industries, sieve trays are widely used as tower internals and their choice is due to economical attractiveness. While operating a trayed distillation tower weeping phenomenon has a critical effect on the efficiency, in this case study a weeping phenomenon was undertaken by means of numerical model in a rectangular sieve tray. Eulerian-Eulerian Computational Fluid Dynamics (CFD) method was used and the obtained CFD results are in a good agreement with the experimental data in terms of weeping rate and pressure drop.

폐액 중 프로필 글리콜 모노메틸 에테르 아세테이트(PGMEA) 회수하는 증류공정에서 회귀분석을 이용한 공정 최적화 (Process Optimization Using Regression Analysis of Distillation Processes for the Recovery of Propylene Glycol Monomethyl Ether Acetate (PGMEA) Containing Waste Organic Solvent)

  • 최용석;변헌수
    • Korean Chemical Engineering Research
    • /
    • 제53권2호
    • /
    • pp.181-192
    • /
    • 2015
  • 본 연구는 Liquid Crystal Display (LCD) 세척 후 발생하는 Propylene Glycol Monomethyl Ether Acetate (PGMEA)폐액 재활용을 위한 2기 증류탑을 사용하는 공정의 최적 조건을 산출하였다. 공정조건 최적화 기법으로 다중회귀분석을 이용하여 1차 증류 시 Bottom 온도(BTM 온도), Reflux 량, Feed 량 및 Feed 온도에 따라 PGMEA 함량에 대한 최적 조건과 2차 증류 시 BTM 온도, Reflux 량, Feed 량에 따른 PGMEA 함량에 대한 최적 조건과 공정인자를 산출하였다. 1차 증류탑의 공정인자 중 Reflux 량, Feed 온도 및 Feed 량이 중요한 인자로 산출되었다. 본 연구의 공정조건 범위에서는 BTM 온도범위가 PGMEA함량에 크게 영향을 주지 못하였다. 따라서 최적 공정 조건은 Feed 량 $5,700{\ell}$, Reflux 량 $2,500{\ell}$, BTM 온도 $165^{\circ}C$ 및 Feed 온도 $130^{\circ}C$이며 이때 예측된 PGMEA 함량은 92.12~94.62%로 산출되었다. 2차 증류탑에서는 Reflux 량이 함량에 많은 영향을 미치고 있으며, Feed 량과 BTM 온도도 영향을 미치는 인자로 산출되었다. 다중공선성(Multicollinearity)이 Reflux 량과 BTM 온도 간에 강한 양의 상관관계가 있어, 두 인자 중 다중회귀식에 영향이 지배적인 인자 하나를 선택하였으며, 최적조건은 BTM 온도 $199^{\circ}C$ 기준에서 최적 공정 조건은 Feed 량 $4,275{\ell}$ 및 Reflux 량 $6,200{\ell}$이며, 이때 예측 PGMEA 함량은 99.0~99.5%로 산출되었다.

행렬부호 함수에 의한 선형 이산치 대규모 계통의 블럭 삼각화 분해 (Block-triangular Decomposition of a Linear Discrete Large-Scale Systems via the Generalized Matrix Sign Function)

  • 박귀태;이창훈;임인성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.185-189
    • /
    • 1987
  • An analysis and design of large-scale linear multivariable systems often requires to be block triangularized form for good sensitivity of the systems when their poles and zeros are varied. But the decomposition algorithms presented up to now need a procedure of permutation, rescaling and a solution of nonlinear algebraic equations, which are usually burden. To avoid these problem, in this paper we develop a newly alternative block triangular decomposition algorithm which used the generalized matrix sign function on the Z-plane. Also, the decomposition algorithm demonstrated using the fifth order linear model of a distillation tower system.

  • PDF

전기화학적 매개산화공정 폐액에서 은 및 질산의 회수 (Recovery of Silver and Nitric Acid in the Liquid Waste Resulted from the Mediated Electrochemical Oxidation Process)

  • 최왕규;김영민;이근우;박상윤;오원진
    • 자원리싸이클링
    • /
    • 제7권3호
    • /
    • pp.17-26
    • /
    • 1998
  • 전기화학적 매개산화 공정에서 발생하는 질산 폐액으로부터 은 및 고농도 질산을 회수하기 위한 연구를 수행하였다. 고농도 질산용액 내에 포함된 은의 회수는 전착법으로 이루어졌으며, 질산농도 3M이하에서는 거의 100%의 전류효율로 98% 이상의 은을 회수할 수 있었다. 또한 질산의 회수를 위한 증발 실험이 수행되었으며, 증발률이 25에서 0.5~1.0mol%의$ NaNO_3$를 함유한 3.5M의 질산 공급폐액으로부터 질산의 절대회수율은 약 80~90%로써 2.8~3.1m의 질산을 얻을 수 있었다. 증발공정에서 회수된 묽은 질산 용액을 고농도 질산용액으로 농축하여 MEO 공정에 재사용하기 위한 처리용량 4kg/hr인 증류탑의 설계 인자 및 운전조건을 Naphtali-Sandholm의 MEH 모델을 사용하여 계산하였다. 단 효율이 70% 이상인 11개의 단으로 구성된 증류탑의 공급단을 6단으로 하고 환류비 0.25, 재비기 열용량 2.7㎾, 응축기 열량 0.5㎾로 운전할 경우 시간당 1.03kg의 12M 질산용액과 2.97kg의 물을 얻을수 있었다.

  • PDF